14.7.4 AMBIENT CONDITIONS
Use
Max altitude
Temperature [min – max]
Minimum lighting level required
Max humidity
Installation category (or surge category)
Electrical insulation class (ref. IEC 61140)
Degree of pollution
Heat emission – device to room, max
Max noise level
Device's IP protection rating
14.7.5 WEIGHT OF DEVICES AND STAINLESS STEEL MATERIALS
[Values in kg]
Model
Weight when empty [no load in
device]
Weight when packed
Maximum weight in use
[+37 kg max load+10 litres of water
intake]
[For 4290, also add +20 kg, detergent
jerry cans]
Max load on floor
Washing chamber
External panelling
14.7.6 CLASSIFICATION OF DEVICES, APPLIED DIRECTIVES AND STANDARDS
Devices are constructed in compliance with the following applied Directives, Regulations and
standards.
Devices are constructed in compliance with the relevant Directives, Regulations and
standards, as stated in their declaration of conformity.
GW1245 - GW0260 - GW1260 - GW4260 -
User Manual
80% for temperatures up to 31 °C with linear decrease to 50% at the
temperature of 40 °C.
GW1245
56
66
79
280kg/m
2
AISI316L
AISI304
GW4290
Indoor
Up to 1,000 m above sea level
From 5 °C to 40 °C
300 lx
II
I
2
600 W (45 cm devices)
900 W (60 cm and 90 cm devices)
60 dB (A)
IPX0
GW0260
GW1260 –
GW4260
72
84
119
119
330 kg/m
2
330 kg/m
AISI 304
AISI 316L
AISI 304
AISI 304
193909119 rev.02
GW4290
72
100
84
116
167
2
310 kg/m
AISI 316L
AISI 304
Page 81 – 91
2