10-5-14. _ REC ATF Level Checking (SS-136 Board)
Mode
Recording
Signal
No signal
Measurement Point
Pin @ of CNSO1
Measuring Instrument | Oscilloscope
Specified Value
710 + 90 mVp-p
Checking method:
1) Confirm that the REC ATF signal level is 710 + 90 mVp-p.
710£90mvp-p
lL ropsecel
Fig, 10-22.
302
10-6.
CHARACTER GENERATOR ADJUSTMENTS
Connect 20-pin extension cord between CN705 on the CT-39
board and CN703 on the VA-68 board.
10-6-1.
Character Generator SG Frequency Adjustment
(CT-39 Board)
Mode
E-E
Signal
Non-signal
Measurement Point
Pin ® of IC902
Measuring Instrument | Frequency counter
Adjustment Element
| CT902
Specified Value
15734 + 100 Hz
Adjusting method:
1) Adjust to 15734 + 100 Hz with CT902.
+
Approx. 4.8 Vp-p
oat
15734 + 100 Hz
Fig. 10-23.