10-5-8.
Y FM Carrier Frequency Adjustment
(VA-68 Board)
Mode
Recording
Signal
No signal
Measurement Point
R158 side terminal of RV101
Measuring Instrument | Frequency counter
Adjusting Element
RV207
Specified Value
4.38 +
0.04 MHz
Adjusting method:
1)
Adjust RV207 for 4.38 + 0.04 MHz.
2)
Perform "Y FM Deviation Adjustment".
3) Make this adjustment again after completing
"Y FM
Deviation Adjustment".
Approx.
0.3 Vp-p
ZL
0.228 usec
Fig. 10-17.
10-5-10.
Y FM Deviation Adjustment (VA-68 Board)
Mode
Recording and playback
Signal
Color bar
Measurement Point
VIDEO IN/OUT terminal (J201)
Measuring Instrument | Oscilloscope
Adjusting Element
RV206
Specified Value
Playback level is 1.00 + 0.05 Vp-p
Note: 1) Confirm that "Emphasis Y Level Adjustment", "PB Y
Level Adjustment" and "Y FM Carrier Frequency
Adjustment" have been completed.
2) Terminate VIDEO IN/OUT terminal (J201) at 75Q.
Adjusting method:
1)
Record the color bar signal.
2) Playback the recorded signal.
3)
Confirm the playback output.
Specified value: 1.00 + 0.05 Vp-p
4)
If not meet the specified value, repeat 1) to 3) after tuning
RV206 in the following manner.
Rotation direction of RV206
When larger than
. .
| specified value
| Clockwise (QO)
When smaller than
;
specified value
Counterclockwise (OQ)
Table 10-2,
a
White (100%)
1.00 + 0.05 Vp-p
Fig. 10-18.
Y FM deviation adjustment
— 800 —