Quick Links

OWNER'S GUIDE
GA ES-1500
GA ES-1500
!
DO NOT THROW AWAY!
SERIAL NUMBER FOR FAN IS LOCATED ON THE BACK COVER OF THE OWNER'S GUIDE.
LEAVE WITH HOMEOWNER

Advertisement

Table of Contents
loading

Summary of Contents for QuietCool GA ES-1500

  • Page 1 OWNER’S GUIDE GA ES-1500 GA ES-1500 DO NOT THROW AWAY! SERIAL NUMBER FOR FAN IS LOCATED ON THE BACK COVER OF THE OWNER’S GUIDE. LEAVE WITH HOMEOWNER...
  • Page 2: Table Of Contents

    2. INSTALLATION ......... . . 5 2.1 Installing GA ES-1500 ....... . . 5 2.2 Setting the GA ES-1500 Fire Damper .
  • Page 3: System Overview

    QuietCool Garage Fan! The QuietCool Garage Fans offer great ventilation options for your garage, man cave, or workshop. We offer the GA ES-1500 Garage Whole House Fan to ventilate both your garage and attic. FEATURES...
  • Page 4: System Venting Requirements

    Venting plays a very significant role in the performace of QuietCool fans. QuietCool recommends a mini- mum of 1 SQ. FT. of venting for every 750 CFM in the QuietCool system. If an attic has at least 1:750 attic venting, the QuietCool system will operate efficiently and effectively. If an attic has less than 1:750 attic venting, the system may not operate as efficiently, or effectively, as it could with 1:750 attic venting.
  • Page 5 5. WATER - The QuietCool system should not be used near water. 6. HEAT - The QuietCool system should be situated away from heat sources. 7. DAMAGE REQUIRING SERVICE - Only qualified service personnel should service the QuietCool system. The user should not attempt to service the product.
  • Page 6: Installation

    ABOVE CEILING FOR INSTALLATION OF GA MODEL FANS. ALWAYS FOLLOW LOCAL BUILDING CODES. Determine in which area you would like to install your QuietCool Garage Attic Fan. Now it’s time to find the exact location using a stud finder or by going up into the attic and finding the location.
  • Page 7: Setting The Ga Es-1500 Fire Damper

    SETTING THE GA ES-1500 FIRE DAMPER The GA ES-1500 includes an integrated fire damper that will automatically close if a fire starts inside your attic. Here are the steps to set the fire damper. The GA ES-1500 ships with the fire damper in the closed position.
  • Page 8: Wiring

    DO NOT USE THE POWER CORD OUTDOORS. If you would like to hard-wire the fan, or it is required by your local building codes, please follow the wiring instructions below. GA ES-1500 WIRING WITH RF CONTROL 1. Using a wire nut, connect the black wire from the power source to the black wire from the Hub.
  • Page 9: Fan Hub Led Indicators

    Figure 3.1A Attach green ground wires to ground screw Set dip switches: 1 - ON 2 - OFF 3 - OFF POWER TIMER TEST PAIR Attic Fan Power Cord All White Common Wires Together FAN HUB LED INDICATORS POWER INDICATOR TEST INDICATOR The Power LED The Test LED indicator will light...
  • Page 10: Pairing The Wall Switch

    If a button on the Wall Switch is not pressed within three minutes of pressing the Pair button on the Hub, the LED indicator on the Hub will go out, indicating unsuccessful pairing. You will need to go back and repeat steps 4 and 5. 1-888-QUIETCOOL...
  • Page 11: Finding A Location For The Wall Switch

    FINDING A LOCATION FOR THE WALL SWITCH 1. It is very important to find the correct location to install the Wall Switch that will allow the Wall Switch to communicate with the Hub. 2. Find the location you would like to install the Wall Switch and test that it properly communicates with the fan to turn the fan on and off.
  • Page 12: System Operating Instructions

    In order for the fan to run, a Timer selection MUST be made. When the Timer status is off (no LED • indicators lit), you can still change the Speed setting. The Speed setting will take effect once the Timer selection is made. FREQUENTLY ASKED QUESTIONS WHAT DOES RF MEAN? “RF” Stands for Radio Frequency. 1-888-QUIETCOOL...
  • Page 13 HOW DOES RF WORK? A small electronic device is used to transmit and/or receive radio signals between two devices. In an embedded system, it often communicates with another device wirelessly. This wireless communication may be accomplished through optical communication or through radio frequency (RF) communication. WILL RF INTERFERE WITH OTHER DEVICES IN MY HOME? The RF will not interfere with other wireless or RF devices in your house.
  • Page 14 No subsequent purchaser of the unit or of a home in which it is installed is entitled to any of the benefits of this warranty. The QuietCool Product that you have purchased has a limited warranty from the date of purchase against defects in workmanship and materials.
  • Page 15: Warranty

    The electrical motor is to be used solely as a direct replacement for a motor of the same model in QC Manufacturing, Inc., QuietCool products. Using the motor in any other product could result in electrical shock and/ or fire, which may cause property damage, serious injury or even death. Any motor replacement should be installed by a qualified licensed electrician in accordance with local, state and national electrical codes and standards.