4-2. Check Items for I/O-PB-11
1
C-In line ID No. & Baud rate set (High speed in-line talken start command)
2
C-In line test termination (Termination command)
3
C-In line CN (connection) type message transmission test
4
C-In line CN (connection) type message reception test
5
C-In line CL (connection less) type message transmission test
6
C-In line CL (connection less) type message reception test
7
C-In line control chip status check
4-3. Operations
1.
C-In line ID No. & Baud rate set (High speed in-line talken start command)
[Operation]
Press
8
0
Press
8
1
The baud rate code is as follow:
m = 0; 156.25 K bps.
m = 1; 312.5 K bps.
Note 1: To stop the test, perform Termination command.
Note 2: Select ID No. from 1 to 32 for test operation.
Note 3: To set the 2 digits ID No., operate as follows:
Press
8
0
Press
n
Press
8
1
[Print sample]
800
OK
814
OK
n
#2
.
(whereas n = Machine ID No.)
m
#2
.
(whereas m = Baud rate code)
m = 2;
625 K bps.
m = 3;
1.25 M bps.
0
#2 .
n
#1 . (whereas n n = Machine ID No. more than 2 digits.)
ID No. = 10 ~ 32.
m
#2 . (whereas m = Baud rate code)
01
— 16 —
ID No.