Gas Dryer Electrical Requirements; Gas Requirements - Maytag MDE20CSTGW Installation Instructions Manual

Commercial gas or electric dryer
Table of Contents

Advertisement

Available languages

Available languages

GAS DRYER ELECTRICAL
REQUIREMENTS
IMPORTANT: Observe all governing codes and ordinances.
This dryer is supplied without an electric cord and plug. It
must be connected by a Whirlpool authorised service person
to a single-phase electricity supply at the voltage shown
on the dataplate, using a suitable fixed wiring installation in
accordance with local and national wiring regulations.
A 3-wire circular cord of minimum conductor size 4.0 mm
cross-section area should be used.
A 10 A supply fuse should be used, and a switch with a clear
OFF marking having a contact separation in both poles that
provides full disconnection under over-voltage category
III conditions must be incorporated into the fixed wiring in
accordance with local wiring regulations. The dryer should
be positioned so that the disconnection switch is clearly
visible and easily accessible to the user. This disconnection
switch also provides the function of an emergency stop
control for the user.
A cord clamp bushing is provided on the dryer, and should
be tightened on completion of wiring. The electrical mains
terminals are located behind the small rear access panel
(terminal block cover), and connections should be made
in accordance with the terminal markings. Remember to
replace the terminal access panel (terminal block cover).
NOTE: In accordance with the European EMC Directive
(2014/30/EU), the maximum electricity supply system
impedance to which the gas dryer should be connected is
declared to be 0.054 Ω + 0.034 Ω.
NOTE: Electrical safety standards: The manufacturer has
chosen compliance with IEC/EN.60335 standards as the
most appropriate for this product.
WARNING
Electrical Shock Hazard
This is a 3-wire appliance which must be earthed.
Securely tighten all electrical connections.
Failure to follow these instructions could result in death,
fire, or electric shock.
If codes permit and an additional ground bond wire is used, it
is recommended that a qualified electrician determine that the
ground bond path is adequate.
10
Recommended Earthing Method:
It is your responsibility to contact a qualified electrical installer
to ensure that the electrical installation is adequate and in
conformance with all local codes and ordinances.
Do not earth to a gas pipe.

GAS REQUIREMENTS

Gas Supply
Use a new CSA International approved gas supply line.
Install a shut-off valve.
2
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (33 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
IMPORTANT: Observe all governing codes and ordinances.
In Australia and New Zealand, refer to AS/NZS 5601.1 – Gas
Installations.
Gas Supply
Before installation, check that the local gas distribution
conditions, nature of gas and pressure, and the adjustment of
the appliance are compatible. Burner information will be found
on the model/serial rating plate in the door recess of the dryer.
If this information does not agree with the type of gas available,
see your dealer.
Natural Gas:
This dryer is factory adjusted for use with NATURAL GAS (G20),
and no further adjustment should be required at installation.
L.P. Gas:
This dryer is also certified for use with L.P. (propane or butane)
gases with appropriate conversion. No attempt shall be made
to convert the appliance from the gas specified on the model/
serial rating plate for use with a different gas without consulting
the serving gas supplier.
Conversion must be done by a Whirlpool authorised service
technician. Gas conversion kit (European Country), part number
W10233219, is available for purchase from your dealer. Gas
conversion kit (Australia), part number W11603127, is available
for purchase from your dealer. Full instructions are supplied
with the kit.
WARNING
Explosion Hazard

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mde20mntgwMdg20cstgwMdg20mntgwMdg20mwtgw

Table of Contents