Advertisement

Quick Links

TANGO®
ACE
EN
User manual *
TG9922- 2020.06
*Original instructions

Advertisement

Table of Contents
loading

Summary of Contents for Electrolux TANGO ACE

  • Page 1 TANGO® User manual * TG9922- 2020.06 *Original instructions...
  • Page 2 Installation diagram...
  • Page 3 DO = Drain outlet CWI = Cold water inlet G 3/8″ EI = Electricity inlet...
  • Page 4 Foreword The installation, use and maintenance manual (hereinafter Manual) provides the user with information necessary for correct and safe use of the machine (or “appliance“). The following must not be considered a long and exacting list of warnings, but rather a set of instructions suitable for improving machine performance in every respect and, above all, preventing injury to persons and animals and damage to property due to im- proper operating procedures.
  • Page 5: Table Of Contents

    Contents A SAFETY INFORMATION ......................... 6 General information ........................6 General safety ..........................6 Personal protection equipment ......................7 Transport, handling and storage ...................... 7 Installation and assembly ....................... 8 Water connection.......................... 8 Electrical connection ........................8 Use ............................9 appliance cleaning and maintenance ....................
  • Page 6: Asafety Information

    SAFETY INFORMATION General information To ensure safe use of the appliance and a proper understanding of the manual it is necessary to be familiar with the terms and typographical conventions used in the documentation. The following symbols are used in the manual to indicate and identify the various types of hazards: WARNING Danger for the health and safety of operators.
  • Page 7: Personal Protection Equipment

    Personal protection equipment Summary table of the Personal Protection Equipment (PPE) to be used during the various stages of the machine's service life. Stage Protective Safety Gloves Glasses Safety garments footwear helmet — ● ○ — ○ Transport — ● ○...
  • Page 8: Installation And Assembly

    Installation and assembly • The installation must be carried out by a specialised personnel. • Follow the installation instruction supplied with the appliance. • Do not install a damaged appliance. Any missing or faulty parts must be replaced with original parts. •...
  • Page 9: Use

    isolation fault in the TN or TT systems or, for IT systems, the use of isolation controllers or differential current protection devices to activate automatic power disconnection (an isolation controller must be provided for indicating a possible first earth fault of a live part, unless a protection device is supplied for switching off the power in case of a such a fault.
  • Page 10: Machine Disposal

    – inadequate or interrupted water supply, steam, air, gas Check on Electrolux Professional website the list of authorized (including impurities and/or other that does not comply customer care. with the technical requirements for each machine);...
  • Page 11: Appliance With 2 Positions Main Switch

    C.4.1 Appliance with 2 positions main switch • keeping combustible or flammable materials, or in any case materials not compatible with or pertinent to the work, near • 0 = appliance OFF the machine; • 1 = appliance ON • wrong machine installation; •...
  • Page 12: Dgeneral Information

    Water Pressure MPa. Water Pressure max port personnel. Manufacturer Electrolux Professional SpA or any other The data plate gives the product identification and technical service centre authorised by Electrolux data. The meaning of the various information given on it is Professional SpA.
  • Page 13: Additional Indications

    This manual is intended solely for consultation by the operator When installing the machine, make sure the and can only be given to third parties with the permission of electrical connection is carried out in compliance ELECTROLUX. with that specified on the data plate. NOTE! Keeping the manual...
  • Page 14: Ftechnical Characteristics

    • knowledge of the regulations on work hygiene and safety. electrical cable sheathing, etc.) the operator for normal machine use must: In case of a significant anomaly (e. g. short circuits, wires coming out of the terminal block, motor breakdowns, worn TECHNICAL CHARACTERISTICS Data table Capacities...
  • Page 15: Screen (Display)

    • Confirm by pressing the “YES“ key for 3 seconds if you have 1. “STOP function“: emptied the drawer, and the “NO“ key if you have not The Stop icon stops a cycle in progress instantly, regard- emptied it. less of what it is. If the “cycle repetition“ function is enabled, press twice to stop.
  • Page 16: Rinsing Cycle

    Cleaning milk • Press this icon to start milk cleaning. • Follow the instructions. • When the cleaning is complete put fresh milk in the milk tank. Detergent part number 92027. Jug part number 54212. External cleaning NOTE! We recommend dismantling the coffee and milk delivery nozzles daily at the end of the service for careful cleaning Rinsing cycle...
  • Page 17: Preventive Maintenance For Coffee Products

    It is advisable to stipulate a preventive and scheduled maintenance contract with the Customer Care Service. Preventive maintenance for coffee products Indication of Different consumption for coffee products. Consumption Coffee/week in Consumption Coffee/ year in Number of cups/weeks (130 Annual Meter Statement CUPS/KG) Inferior to 15 Inferior to 800...
  • Page 20 Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www.electroluxprofessional.com...

This manual is also suitable for:

602554602557602556

Table of Contents