Auto set-up probe

Advertisement

5.
While pressing the Auto Setp-up key board's "ESC"
key,
check to see that the same menu as item-! will appear on
the monitor screen.
When the "ESC" key is pressed
the menu
will be displayed on
the monitor screen.
AUTO
SETUP
ADJ
PGM
ESET
D-A
CONVERTER
BKM-2053
ADJ
BKM-2053
INITIALIZE
FOR
SERVICEMAN
USE
6.
Move the Auto Set-up key board's cursor key "GQ" in order to
select *BKM-2053 INITIALIZE". Install the probe onto the
CRT screen surface according to the instruction given on
the monitor screen, and press the "ENT" key.
Move the cursor key "(&)" to
select "BKM-2053 INITIALIZE", | AUTO SETP ADJ PGM
SET
D-A CONVERTER
—EBKM-2053
ADJ
BKM-2053
INITIALIZE
FOR
SERVICEMAN
USE
Attach
the probe
tightly to the
screen and press the "ENT" key
in accordance
with the instruc-
tion.
SET PROBE
ON CRT
——-—PRESS
ENT
—--——
7.
Select either one of the BKM-2053-01 (USA), BKM-2053-02
(E), OR BKM-2053-03 (J), by using the "cursor shift'Gkey.
Press the "ENT" key.
Select destination by means
of "cursor shift' [) key.
PROBE
VERSION
BUSA
E
J
Press the "ENT" key. If the
dispaly comes out on monitor,
8.
Press the Auto-set up key board's either "RESEI™ key or
the "ESC" key. The auto setup white balace adjustment
mode will be released.
Note 1:
In the case "PROBE NOT CONNECTED!"
is still displayed
even if the adjustments of steps | to7 are performed re peatedly
two or three times, check mainly centering around thel B board.
PROBE
NOT
CONNECTED!
Note 2:
The data which has been memorized into the memory of D9300
(16500) is converted to 40fL with BKM-1450 by this adj ustment
Accordingly, even if it is memorized at 30fL, it is autanatically
set up to 40fL as the set up BKM-1450.
5-3(E)