iHealth Track KN550-BT - Fully Automatic iHealth Track Connected Arm Blood Pressure Monitor Manual

iHealth Track KN550-BT - Fully Automatic iHealth Track Connected Arm Blood Pressure Monitor Manual

Advertisement

iHealth Track KN550-BT - Fully Automatic iHealth Track Connected Arm Blood Pressure Monitor Manual

GENERAL SAFETY AND PRECAUTIONS

  1. Carefully read the user guide before operating the device.
  2. Consult your physician for any of the following situations:
    1. The application of the cuff over a wound or inflamed area.
    2. The application of the cuff on the arm on the side of a mastectomy.
    3. Simultaneous use with other medical monitoring equipment on the same limb.
    4. The application of the cuff on any limb with intravascular access or therapy, or an arteriovenous (A-V) shunt.
    5. The blood circulation of the user needs to be checked.
  3. Do not use this product in a moving vehicle as this may result in inaccurate measurements.
  4. The IHB symbol will be displayed under 2 sets of circumstances:
    1. The coefficient of variation (CV) of pulse period >25%.
    2. The difference of adjacent pulse period is ≥0.14s and more than 53% of the total number of pulses readings falls within this definition.
  5. Please do not use any cuff other than that supplied by the manufacturer as this may result in inaccurate measurements.
  6. The monitor will show 'HI' or 'Lo' as technical alarm on LCD with no delay if the determined blood pressure (systolic or diastolic) is outside the rated range specified in part SPECIFICATIONS. In this case, you should consult a physician or check if your operation violated the instructions. The technical alarm condition (outside the rated range) is pre-set in the factory and cannot be adjusted or inactivated. This alarm condition is assigned as low priority according to IEC 60601-1-8. The technical alarm is non-latching and needs no reset. The signal displayed on LCD will disappear automatically after about 8 seconds.

warning This Monitor is designed for adults and should never be used on infants, young children or patients with preeclampsia.
warning This product might not meet its performance speci cations if stored or used outside the speci ed temperature and humidity ranges.
warning Please do not share the cuff with any infectious person to avoid cross-infection.

  1. Prolonged over-in ation of the bladder may cause bruises of your arm.

MEASURING BLOOD PRESSURE – A FEW BASICS

Blood Pressure Monitor that uses the oscillometric principle to measure your blood pressure and pulse rate. Blood pressure fluctuates continually day and night. Any physical activity or excitement will influence your blood pressure. Because of this, it is unusual to obtain identical multiple blood pressure readings. This is why it is recommended that you measure your blood pressure at approximately the same time every day.

  1. Relax for 5 minutes before taking your blood pressure.
  2. Sit comfortably at a table when measuring your blood pressure.
  3. The cuff should be placed at the same level as your heart.
  4. Do not talk or move during a measurement.
  5. Use the same arm every time.
  6. Remove the batteries from the device if it is not used for a month or more to avoid battery leakage.
  7. This blood pressure monitor is designed for adults and should not be used on children.
  8. It is not recommended for people with serious arrhythmia to use this device.
  9. Do not use any other cuff than the one supplied by iHealth.
  10. Relax

WHAT YOUR DEVICE SHOULD LOOK LIKE

The explanation of symbols on the display:
Bluetooth Symbol
Synchronization Symbol
Release Air Symbol
Memory Indicator
Low Battery Indicator
Irregular Heartbeat Symbol
Blood Pressure Level Classification Indicator

Device Overview

WHY YOU SHOULD CONNECT YOUR DEVICE

Taking a measurement is easy. It's what you do with the measurement that is important. You can use your device as a stand-alone device just to measure your blood pressure, but when you connect it to the free iHealth MyVitals App you will be able to track, store, manage and share your results with your family, doctor or care givers. Simply download iHealth MyVitals on the Apple Store or on GooglePlay and start managing your health.

www.apple.com

play.google.com

Your iHealth account also gives you access to the free and secure iHealth cloud service so that you can manage your data, watch your trends and share your data. To do this, visit www.ihealthlabs.eu and log in using the same account as you used with your App.

The iHeath Track Blood Pressure Monitor is designed to be used with Bluetooth 4.0 Apple devices and selected Bluetooth 4.0 Android smartphones. Please note that the compatible devices are subject to change. For the latest compatibility list visit www.ihealthlabs.eu/support.

HOW TO USE YOUR DEVICE

BATTERIES

  1. Open the battery cover at the back of the device.
  2. Load four "AAA" size batteries. Please pay attention to polarity.
  3. Close the battery cover.

warning When the display shows the battery symbol ( ), replace all the batteries with new ones. Rechargeable batteries are not suitable for this monitor.

HOW TO PLACE THE CUFF ON YOUR ARM

The iHeath Track Blood Pressure Monitor has a universal size cuff. This means that it will fit any arm with a circumference between 22 and 42cm. If your arm is too large to fit in this cuff, you might consider using a wrist blood pressure monitor.

  1. Place the cuff tube downwards, around a bare arm about 2cm above the elbow joint.
  2. Sit with your feet at on the floor without crossing your legs. While seated, place your palm upside in front of you on a flat surface such as a table Lying Down During Measurement: (You can also lie on your back and place your left arm straight along your side with your hand palm-side up.) Position the air tube in the middle of your arm in line with your middle finger.
    HOW TO PLACE THE CUFF ON YOUR ARM
  3. Close the cuff with the Velcro fastener.
  4. The cuff should fit comfortably around your arm. You should be able to insert one finger between your arm and the cuff.

Note: If the cuff becomes dirty, remove it from the monitor and wipe it with a lightly moistened soft cloth. Then air-dry the cuff. Do not machine wash. Cleaning the cuff after every 200 measurements is recommended.

CONNECTING THE CUFF TO THE DEVICE

Once you have determined that the cuff fits your arm (22 – 42cm), simply insert the cuff connector into the socket on the side of the monitor. Ensure that the connector is completely inserted to avoid air leakage.
Avoid compression or restriction of the connection tubing during measurement which may cause in ation error, or harmful injury due to continuous cuff pressure.

SETTING THE DATE AND TIME

Insert the batteries in the device and connect it with the iHealth MyVitals App on your smartphone. The time and date will automatically be updated. If you change the batteries, please readjust the time and date again.

TAKING A BLOOD PRESSURE MEASUREMENT

  1. After placing the cuff on your arm and relaxing for a few minutes, press the "START/STOP" button. All display characters are shown for self-test, please contact the service center if segment is missing.
  2. The monitor will in ate the cuff and then slowly release pressure from the cuff as the blood pressure is measured. When the measurement is nished the blood pressure and pulse rate will be displayed on the display. The blood pressure will be displayed in di erent colours (green for normal, yellow for slightly elevated, and red for high) according to the recommendations of the WHO (World Health Organization), The result will automatically be stored in the memory bank of the monitor.
  3. If an Irregular Heartbeat (IHB) is detected during a measurement, the IHB symbol will be displayed (blinking). If an IHB is detected, the results of the blood pressure measurement may be inaccurate. Please consult your physician for an accurate assessment.
  4. At any time you can synchronize your device with the iHealth MyVitals App so that you can better manage your blood pressure.
  5. The monitor will automatically switch off after one minute to save the batteries. Alternatively, you can press the "START/STOP" button to turn off the monitor manually.
  6. At any time during a measurement, you can interrupt a measurement by pressing the "START/STOP" button.
CLASSIFICATION OF BLOOD PRESSURE AND BACKLIGHT INDICATOR
BLOOD PRESSURE CLASSIFICATION Systolic mmHg Diastolic mmHg BACKLIGHT INDICATOR
Optimal 91–119 and 61 - 79 Green
Normal 120-129 and 80 -84 Green
High-normal 130-139 or 85 - 89 Yellow
Grade 1 Hypertension 140-159 or 90 - 99 Flashing Yellow
Grade 2 Hypertension 160-179 or 100–109 Red
Grade 3 Hypertension ≥180 or ≥110 Flashing red

MEMORIES

You can review previous readings by pressing the "M" button twice. The rst memory displayed will be the average of the last three measurements. When the average of the last three measurements display, press the "M" button, the newest measurement will display. Press "M" button again to review the next measurement. During display the memories, keep on pressing button "M" for three seconds, all results in the current memory bank will be deleted.
If no result stored, LCD will show zero.

The monitor will automatically switch off after one minute to save the batteries. Alternatively, you can press the "START/STOP" button to turn off the monitor manually.

SYNCHRONIZING WITH THE IHEALTH MYVITALS APP

Before you can synchronize all your blood pressure readings, you need to download the iHealth MyVitals App on your smartphone from the Apple Store (for iOS devices) or on GooglePlay Store (for Android). You then need to create your own iHealth account on the App.

www.apple.com

play.google.com

To synchronize:

  1. Place your phone next to your blood pressure monitor.
  2. Start the iHealth MyVitals App on your smartphone (ensure that your Bluetooth is activated in your settings).
  3. Press the "M" (Memory) button on the blood pressure monitor. The number of readings in the memory will be displayed. After a few seconds the iHeath Track Blood Pressure Monitor will automatically start synching the readings to the iHealth MyVitals App. While it is synchronizing you will see the readings numbers gradually come down on the blood pressure monitor, until they reach zero. When zero is displayed on your monitor, it means that all the readings have been synchronized and that you can new view all your data in the "List" of the iHealth MyVitals App.
  4. If no result stored, the number of readings in the memory will be displayed zero.

TROUBLESHOOTING

Problem Explanation Solution
LCD shows low battery symbol Low Battery Change all the batteries
LCD shows "Er 0" Pressure system is unstable before measuremente Try again without moving
LCD shows "Er 1" Fail to detect systolic pressure
LCD shows "Er 2" Fail to detect diastolic pressure
LCD shows "Er 3" Pneumatic system blocked or cuff is too tight during inflation Apply the cuff correctly and try again
LCD shows "Er 4" Pneumatic system leakage or cuff is too loose during inflation
LCD shows "Er 5" Cuff pressure above 300mmHg Measure again after 5 minutes. If the error is still there, please contact your local iHealth distributor
LCD shows "Er 6" More than 3 minutes with cuff pressure above 15 mmHg
LCD shows "Er 7" EEPROM accessing error
LCD shows "Er 8" Device parameter checking error
LCD shows "Er A" Pressure sensor parameter erroron
No response when you press button or install batterypiles Incorrect operation or strong electromagnetic interference. Take out the batteries, wait five minutes and then reinstall batteries

Please visit the support section of the www.ihealthlabs.eu website to see our comprehensive Frequently Asked Questions on blood pressure.

CARE AND MAINTENANCE

  1. Do not drop the monitor or subject it to strong impacts.
  2. Avoid high temperature and direct exposure to the sun. Do not immerse the monitor in water.
  3. If this monitor is stored near freezing temperatures, allow it to acclimate to room temperature before use.
  4. Do not attempt to disassemble this monitor.
  5. If you do not use the monitor for a long time, please remove the batteries.
  6. It is recommended that the performance of this monitor be checked every 2 years.
  7. Please clean monitor with a soft dry cloth. Do not use any abrasive or volatile cleaners.
  8. The supplier will make available on request the circuit diagrams, component part lists, descriptions, calibration instructions, or other information which will assist the user's appropriately quali ed technical personnel to repair those parts of equipment which are designated by the manufacturer as repairable.
  9. It is recommended that if the cuff is used in a hospital or a clinic, it be disinfected twice a week. Wipe the inner side (the side that contacts skin) of the cuff with a soft cloth lightly moistened with Ethyl alcohol (75-90%). Then air dry the cuff.
  10. The monitor can maintain the safety and performance characteristics for a minimum of 10,000 measurements or three years, and the cuff integrity is maintained after 1,000 open -close cycles of the closure.

AFTERSALES AND WARRANTEE

If you have any questions regarding the aftersales or usage of the product, please visit www.ihealthlabs.eu and consult our Frequently Asked Questions on blood pressure (in our support section). If you do not nd the answers you are looking for, please send us a query directly from the website. If you have any suggestions so that we can improve our products, please send us a mail at support@ihealthlabs.eu.

ANDON HEALTH CO., LTD
Add: No. 3 Jinping Street, YaAn Road, Nankai District, Tianjin 300190, China.
Tel: 86-22-60526161

SPECIFICATIONS

Product name: iHeath Track Blood Pressure Monitor
Model: KN-550BT
Classification: Internally powered, type BF applied part; IPX0, No AP or APG; Continuous operation
Machine size: 98 × 98 × 46mm
Cuff circumference: 22 - 42cm
Weight: 348g (batteries and cuff included)
Measuring method: oscillometric method, automatic inflation and measurement
Memories: 99
Power source: 4x1.5V SIZE AAA batteries
Measurement range:
Cuff pressure: 0 - 300mmHg
Systolic: 60 - 260mmHg
Diastolic: 40 - 199mmHg
Pulse rate: 40 - 180 beats/minute
Measuring accuracy: Pressure: ±3mmHg, Pulse rate: ±5%
Environmental temperature for operation: 10~40°C
Environmental humidity for operation: ≤85%
Environmental temperature for storage: -20~50°C
Environmental humidity for storage: ≤85%
Environmental pressure: 80~105kPa
Battery life: Approximately 250 readings
This blood pressure measurement system includes accessories: pump, valve, cuff, and sensor.

Note: These specifications are subject to change without notice.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download iHealth Track KN550-BT - Fully Automatic iHealth Track Connected Arm Blood Pressure Monitor Manual

Advertisement

Need Assistance?

Do you have a question about the Track KN550-BT that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents