Download Print this page

Honeywell S8600A Manual page 3

Intermittent pilot modules
Hide thumbs Also See for S8600A:

Advertisement

2 I511
:
b
2: [671
b
Lh
ONLY ON MODELS
WITH VENT DAMPER
PLUG.
M1123
._
____
--.._--.__-__-_-~.-
___.
_
_
FIG. l-APPROXIMATE
IGNITION MODULE
DIMENSIONS
IN In. [mm].
ELECTRICAL
RATINGS:
Voltage and frequency:
20.5 to 28.5 V (24 V nom.), 60
HZ.
CANADIAN GAS ASSOCIATION
CERTIFIED:
1029-ABI-
6269.
Current rating: 0.2 A.
AMERICAN
GAS ASSOCIATION
DESIGN CERTIFIED:
20-l 4D3.
Valve contact ratings (at 24 Vat):
S8600, S8660
S8610, S8670
Run
1
Inrush
Run
1
Inrush
Pilot
l.OA
1
lO.OA
1.0 A
1
lO.OA
Main
1
l.OA
1
lOoA
I
2.0A
t
20.0A
SPARKGENERATOROUTPUT:
13 kVpeakat25
pf load.
THERMOSTAT
ANTICIPATOR
SETTING: 0.2
A plus
pilot
valve rating plus main valve rating.
AMBIENT TEMPERATURE
RATING:
S8600,58660:
-40" F to +175" F [-40° C to +79O C].
S8610, S8670: -40" F to +175" F [-40° C to +79" C] with
main valve rated 1 .O A or less; -40" F to +165' F [-40°
C to +74" C] with main valve rated over 1 .O A to 2.0 A.
RELATIVE HUMIDITY RATING: 5 to 90 percent
RH at
95" F.
FLAME FAILURE RESPONSE
TIME: 0.8 sec. at 1 .O uA
flame current.
CONTINUOUS
RETRY TIMING (SSSOOM only): 5 minute
min., 6 minute nom. off time between trials for ignition.
TERMINALS:
SENSE
(S8600A,B;
S8610A,B
only): 3/16 in. male
quick connect.
All otherterminals,
including ignition: l/4 in. male quick
connects. Models available with Molex plug forconnec-
tion to Honeywell
D80D Vent Damper.
FLAME CURRENT:
1 ).LA, min.
MOUNTING: Mounts in any position except with terminals
up. However,
recommended
mounting position is with
terminals
down to provide
maximum
protection
from
dripping water or dust accumulation.
Fasten with No. 6-
32 machine or No. 8 sheetmetal
screws of appropriate
length.
UNDERWRITERS
LABORATORIES
INC. COMPONENT
RECOGNIZED:
File No. MH15564, Guide No. MCCZ2.
OTHER SYSTEM COMPONENTS
These modules provide operating control of an intermit-
tent pilot system.
Additional
components
required
to
complete
the system must be ordered
separately.
They
include:
Dual valve combination
gas control designed
for
intermittent
pilot
Combination
pilot burner/igniter-sensor
(S8600F,H,M;
S8610F,H;
and S8670D)
Separate
igniter and sensor on pilot burner bracket
(S8600A,B)
Ignition cable
Transformer
24V thermostat
High limit and other auxiliary controls as required
DUAL VALVE COMBINATION
GAS CONTROL: Any that
meets current ratings listed below. VR8204, VR8440 or
VR8520 recommended.
S8600, S8660: 1 .O A pilot, 1 .O A main valve.
S8610, S8670: 1 .O A pilot, 2.0 A main valve.
PILOT BURNER/IGNITER-SENSOR:
See Table 2.
TABLE 2-PILOT
BURNER/IGNITER-SENSORS.
PILOT BURNEW
FLOW RATE*
MODULE
IGNITER-SENSOR
cfh
1
m3/hr
S8600F.H.M:
Q345
0.8
1
0.02
S8610F;H;
Q346
1.0
0.03
S8660D;
Q348
1.5
0.04
S8670D
Q362
0.5
0.014
Q381
0.5
0.014
S8600A,B
Q179C
)
1.8
1
0.05
Q354 with Q345. Q346. Q348. Q362 or
'With natural gas at 7.0 in. WC [1.7 kPa].
3
68-0085-2

Advertisement

loading