Samsung AC Series Install Manual

Led display
Hide thumbs Also See for AC Series:

Advertisement

Quick Links

LED Display Install Manual
IAC Series
LH015IAC***
Ver. 0.3
LED R&D Lab(VD)

Advertisement

Table of Contents
loading

Summary of Contents for Samsung AC Series

  • Page 1 LED Display Install Manual IAC Series LH015IAC*** Ver. 0.3 LED R&D Lab(VD)
  • Page 2 Revision History Version Date (Y/M/D) Description 2023/06/01 Release ver 0.1 Modification Side by Side Content (P114~118) 2023/06/12 Delete Side by Side Screen Split scenario #2 (P119) 2023/06/15 Add checking CABINET number (BNV20231FE9) (P18,20) LED R&D Lab(VD)
  • Page 3: Table Of Contents

    Table of contents 1. Product and installation information 2. Preparation of Cabinet installation 3. Wall Mount 4. Frame installation and cable connection 5. Frame Bezel Installation 6. Dehumidification mode guide 7. IP Manual setting Guide ※ Appendix1 - LED MODULE and CIRCUIT replacement method ※...
  • Page 4: Product And Installation Information

    1. Product and installation information ◆ Model specification - This manual is an installation manual for IAC and can be applied to the model below. MODEL Product appearance and information IAC series IAC Series : Package Type / 60 Hz Refresh Rate REMARK LED R&D Lab(VD)
  • Page 5 1. Product and installation information ◆ Model specification (IAC) 130” Specifications P1.5 2888.55 Horizontal Size (mm) 1628.55 vertical Horizontal 1920 Resolution (Pixels) 1080 vertical Module (EA) 27 X 4 (108) weight (kg) 16.0 CABINET (Cabinet) 124.55 SET weight (kg) 78.9 Packing weight (kg) Power consumption (W) Typical 685W (Max 1660W)
  • Page 6 1. Product and installation information ◆ Cabinet product information 2888.55 62.2 1628.55 130” LED R&D Lab(VD)
  • Page 7 1. Product and installation information ◆ Installation precautions (LED damage) precautions Image [External impact, fall caution] MODULE 1 Remove the cover-corner of the product before installation and do not Front impact the LED surface or drop it on the floor. ①...
  • Page 8 1. Product and installation information ◆ Installation precautions (LED damage) precautions Image [Caution of LED damage caused by liquid] When water or various chemicals touch the LED, the inside of the LED may be damaged. ① Water, dew, air conditioner condensate, sprayer, sweat, and saliva do not directly touch the product.
  • Page 9 Video, created based on back light 10  Installation condition - Conditions for using SAMSUNG WALL MOUNT - Solar direct sunlight conditions cannot be installed (including glass window passage conditions) - It is recommended to use room temperature below 25°C...
  • Page 10 1. Product and installation information • Vertical wall installation (if Fan is not applied) set ~ ceiling minimum 30mm Air vent area set ~ floor minimum 30mm LED R&D Lab(VD)
  • Page 11 1. Product and installation information • Vertical landfill installation (when Fan is not applied) Recommended conditions: 500mm or more set ~ ceiling Air vent area At least 30mm (opening rate 100%) Minimum distance If the aperture ratio is not 100%, the separation distance = aperture ratio(%) / 100 At least 30mm (opening rate 100%) Recommended conditions: 500mm or more...
  • Page 12 1. Product and installation information • Precautions for Landfill Installation 150mm left and right space is required for service. (Fig.1)  Fixed screws are placed inside. , it is necessary to secure a field of view of about 150mm. (Fig. 2) ...
  • Page 13 1. Product and installation information ◆ Setup ready ※ Recommended Specifications Electric driver PROTECTION JIG ASSY COVER P-HANDLE BN81-17515B BN96-55707A (-) (+) driver • It is provided for Set accessories. BRACKET-LINK ASSY COVER P-DECORATION ASSY ACC-WALL MOUNT ASSY ACC-WALL MOUNT (BN61-18825A) (BN96-57387A~57390A, and (BN96-54014L)
  • Page 14 1. Product and installation information ◆ Cabinet Accessories BRACKET-LINK ASSY COVER P-DECORATION Product warranty Quick setup guide Specification guide BN61-18825A (BN96-57387A~57390A, and (It is not provided in some areas. ) BN96-57380B) WALL MOUNT ACC T-CON SVC SMPS SVC ACC MANUAL CABLE SVC MODULE (6EA) BN96-54014L/M BN94-18201A...
  • Page 15 1. Product and installation information □ Features when configuring the Screen( Different specifications compared to the existing ones ▶ Connection structure: Connect the signal cable (OCM) and power cable between P-FRAME and Front P-FRONT 1) P-FRAME Left/Right Connection - Power unit on cable connection between AC Inlet Boards - Connect the left/right cable of the speaker 2) Cable connection between P-FRAME + P-FRONT - Connect four OCM cables to the Main Board Video output port...
  • Page 16 Table of contents 1. Product and installation information 2. Preparation of Cabinet installation 3. Wall Mount 4. Frame installation and cable connection 5. Frame Bezel Installation 6. Dehumidification mode guide 7. IP Manual setting Guide ※ Appendix1 - LED MODULE and CIRCUIT replacement method ※...
  • Page 17: Preparation Of Cabinet Installation

    2. Preparation of Cabinet installation ◆ Pre-prepare before installation ① To remove SET packaging, a ceiling space 600mm higher than the minimum SET packaging is required. ② If there is not enough space, disassemble the SET packaging in the possible space and move the cabinet to the installation space.
  • Page 18 2. Preparation of Cabinet installation ◆ Pre-prepare before installation There are number of cabinet ① Remove the tape of the top BOX and open it. (Fig.2) ② Remove the top–cushion. ③ Check the set status. (Two rear parts and four front parts) (Fig.3) Right1 Top-Cushion...
  • Page 19 2. preparation of Cabinet installation ◆ Pre-prepare before installation ④ Open the bag shielding of the front module. Hold the internal COVER-CORNER, take out the set, and open the AL-Bag and disconnect the AL screws (4 in total). (Fig.4) ⑤ Disconnect the screw of the COVER-CORNER part. (4 locations) (Fig.5) ※...
  • Page 20 2. preparation of Cabinet installation ◆ Pre-prepare before installation ⑥ Remove some of the HOLDER-PCB materials assembled in the cabinet. (Refer to the removal point in the next PAGE) ※ Be careful because the location of the HOLDER-PCB that must be removed is different for each cabinet number! Screw point HOLDER-PCB Remove the HOLDER-PCB by loosening the screw.
  • Page 21 2. preparation of Cabinet installation ◆ Pre-prepare before installation ⑦ Remove some of the HOLDER-PCB materials assembled in the cabinet. ※ Be careful because the location of the HOLDER-PCB that must be removed is different for each cabinet number! Check cabinet number - Remove the red area in the figure below.
  • Page 22 Table of contents 1. Product and installation information 2. Preparation of Cabinet installation 3. Wall Mount 4. Frame installation and cable connection 5. Frame Bezel Installation 6. Dehumidification mode guide 7. IP Manual setting Guide ※ Appendix1 - LED MODULE and CIRCUIT replacement method ※...
  • Page 23: Wall Mount

    3. Wall Mount Wall Mount Item 130” ASSY BRACKET P-WALL REAR LEFT ASSY BRACKET P-WALL REAR RIGHT ASSY ACCESSORY-SPACER BOLT-ETC HOLDER-BOLT HOLDER-WALL RING LABEL LEAFLET-WALL MOUNT BRACKET-SUPPORT M3,L6 SCREW-SPECIAL (M3,M6) SCREW-MACHINE (M4,L6) SCREW-MACHINE (M3,L5) SCREW-MACHINE (M4,L12) BOLT-ETC (M6,L10) M3,L5 M4,L12 M4,L6 M6,L10 BRAKCET-LINK...
  • Page 24 Table of contents 1. Product and installation information 2. Preparation of Cabinet installation 3. Wall Mount 4. Frame installation and cable connection 5. Frame Bezel Installation 6. Dehumidification mode guide 7. IP Manual setting Guide ※ Appendix1 - LED MODULE and CIRCUIT replacement method ※...
  • Page 25: Frame Installation And Cable Connection

    4. FRAME installation and cable connection ※ Cautions when fixing screws 1. A concrete or design wall with sufficient thickness; Standard Conditions for Installation according to the Types of Walls It can be installed on concrete or interior walls that are thick enough. Wooden pillars or MDF walls in gypsum boards If the wall is not flat, the gap...
  • Page 26 4. FRAME installation and cable connection ① Install the wall mount on the wall. (The same method as WALL 2.0) - Attach the leaflet to the wall to locate the wall mount. - Check the horizontal state using a laser leveler - Fix the left and right two points to the wall using the enclosed screw.
  • Page 27 4. FRAME installation and cable connection ② Remove the protective packaging of the rear docking portion. (To work by lying on a table or packaging material. Caution because it can shock the protruding part when working while standing) (1) Open the AL shielding bag of the docking part. (Fig.1) (1) Remove the front protection PAD fixed to the docking part.
  • Page 28 4. FRAME installation and cable connection ③ Before installing FRAME on Wall Mount, the following connection is required - Connect the power cable to the left frame and right frame, respectively - Power Cable – Connects 2Power Cord - Since it is difficult to access after installation depending on the environment, connect the external terminal(HDMI, LAN, DP, etc.) cable to be used ※...
  • Page 29 4. FRAME installation and cable connection ④ Install the ASSY BRACKET P-FRAME on the wall mount. - Install the LEFT first. - Fix it to the wall mount using BRACKET-WALL attached to the rear. - BRACKET-WALL SHAFT is used when horizontal adjustment between rear FRAME is required. BRACKET-WALL SHAFT BRACKET-WALL Fig.1 Install LEFT first...
  • Page 30 4. FRAME installation and cable connection ⑤ Install the ASSY BRACKET P-FRAME on the wall mount. - After installing the LEFT, install the RIGHT in the same way. - Assemble the combined parts of LEFT and RIGHT using screws. (4 POINTS) M6,L10 Fig.2 Assemble LEFT and RIGHT Fig.1 Install RIGHT...
  • Page 31 4. FRAME installation and cable connection ⑥-1 Attach SPACER to utilize the space at the bottom of ASSY BRACKET P-FRAME ** This course is not an essential course that must be done (Attach only when a gap between the bottom of the SET and the wall is required) - Attach the SPACER enclosed in the Accessory kit to the bottom of the COVER REAR.
  • Page 32 4. FRAME installation and cable connection ⑥-2 Close the bottom of ASSY BRACKET P-FRAME to the wall ** This course is not an essential course that must be done (Use only when you need to fix the bottom part completely) - Fix the bottom part using the bolt and ring enclosed in the Accessory kit Holder ring Anchor bolt...
  • Page 33 4. FRAME installation and cable connection ⑥-3 Install the ASSY BRACKET P-FRAME on the wall mount. - When connecting the second set, repeat the previous page operation twice. M6,L10 Fig.1 2SET install LED R&D Lab(VD)
  • Page 34 4. FRAME installation and cable connection ⑦ Assemble the BRACKET-LINK. - BRACKET-LINK assembles top and bottom - Use the screw K (M4,L6) M4,L6 Assemble point Assemble point Fig.2 BRACKET-LINK assemble LED R&D Lab(VD)
  • Page 35 4. FRAME installation and cable connection (130”) ⑧ Connecting the cable in the frame section below ① Connect 10P to 10P Harness(BN39-02728A) connected to Right-Frame Inlet b’d to the bottom of Left-Frame Inlet b’d ② Connect Right-Frame Speaker Cable ↔ Left-Frame Speaker Cable LEFT-FRAME RIGHT-FRAME SMPS...
  • Page 36 4. FRAME installation and cable connection (130”) ⑧ Connecting the cable in the frame section below ③ BN39-02743B(OCM) to Main OCM1, spread it over the L1 Frame fixed injection, and hang it. ④ BN39-02743A(OCM) to Main OCM2, spread it over the L2 Frame fixed injection, and hang it. ⑤...
  • Page 37 4. FRAME installation and cable connection ⑨ Install the SSY BRACKET P-FRONT by hanging it on the ASSY BRACKET P-FRAME. (Note No. 1) ※ Be sure to be aware of the instructions below and install the FRONT. - Check the cable alignment status of the REAR part before installing the FRONT. - If the cable is mounted on the part shown below, change the align as shown below.
  • Page 38 4. FRAME installation and cable connection ⑨ Install the ASSY BRACKET P-FRONT by hanging it on the ASSY BRACKET P-FRAME. (Note No. 2) Watch out collisions. ※ Be sure to be aware of the instructions below and install the FRONT. - Be careful not to collide with the left and right FRONTs when installing FRONTs.
  • Page 39 4. FRAME installation and cable connection ⑨ Lift the ASSY BRACKET P-FRAME using BRACKET-HANDLE. (Note No. 3) ※ Be sure to be aware of the instructions below and install the FRONT. - Insert HANDLE into FRAME as shown in Figure 1. - Push it in the direction of the FIG.2 arrow to fix it.
  • Page 40 4. FRAME installation and cable connection ⑨ Install the ASSY BRACKET P-FRONT by hanging it on the ASSY BRACKET P-FRAME. - After installing 1st and 2nd in the middle, install them in order of 3rd and 4th. ※ Be sure to read the precautions 1, 2, and 3 on the previous page and install. - Be sure to comply with the installation order - Since it is installed by hanging, it is raised and installed at an angle.
  • Page 41 4. FRAME installation and cable connection (130”) ⑩ Connect the cable below whenever you hang one ASSY BRACKET P-FRONT to the P-FRAME. - After creating a space by pulling the bottom of the P-FRONT, connect the OCM cable to the CN311 of the BN41-03167A board - After attaching P-FRONT to P-FRAME, connect BN41-03167A of P-FRONT and BN41-03167A of P-FRAME - The pile of cables exposed to the bottom of the set is pushed into the gap between P-FRONT and P-FRAME LEFT-FRAME...
  • Page 42 4. FRAME installation and cable connection ⑪ Check the operation of each ASSY BRACKET P-FRONT installation. Be sure to read the following precautions when lifting the cabinet for cable connection. - If the two cabinets are lifted completely attached, there is a possibility of module damage due to collision between modules. (Fig1.) - Be sure to lift it with a gap of more than 5mm left and right.
  • Page 43 4. FRAME installation and cable connection ⑪ Check the operation of each ASSY BRACKET P-FRONT installation. - Connect the power of the SET power cord to check whether the entire LED is damaged or not and check the output. Fig.2 Check the operation after installing two Fig.1 Check the operation after installing one Fig.3 Check operation after installing three Fig.4 Check operation after installing four...
  • Page 44 4. FRAME installation and cable connection ⑫ How to use PROTECTION JIG - Minimize damage to LED modules by attaching them when the waiting time is long or movement is required after installing the cabinet - It is also used when it is necessary to hold the side surface by hand. Fig.2 Fig.1 Jig attachment position LED R&D Lab(VD)
  • Page 45 4. FRAME installation and cable connection ⑫ After assembling two or more ASSY BRACKET P-FRONTs, match each other's Z seams. <Z seam control method> - Use a driver to open the space between the two modules. Push driver Module moving direction Fig1.
  • Page 46 4. FRAME installation and cable connection ⑬ After assembling two or more ASSY BRACKET P-FRONTs, match each other's Z gaps. < Z gap control method > - The concept of pushing up the lower side - Open the distance between the two modules. Figure 1 - Adjust the gap by turning the middle gear using the straight driver.
  • Page 47 4. FRAME installation and cable connection ⑬ LEFT and TOP DECO are assembled first in order to create an environment where SET tilt can be adjusted. 2. TOP DECO Installation 3. Screw coupling 1. LEFT DECO Installation Fig.1 Deco assembling sequence Fig.2 Completion of assembling LED R&D Lab(VD)
  • Page 48 4. FRAME installation and cable connection ⑬ Check if the screen position is correct based on the DECO GAP PAD, and then adjust the screen position. - Adjust the X-axis position based on the DECO position and then adjust the Y-axis position. GAP PAD 0.1mm DECO SIDE...
  • Page 49 4. FRAME installation and cable connection ⑭ Move the headless bolt through the hole of the DECO TOP - The SET tilt can be removed using a headless bolt and the Y-axis can be adjusted to remain horizontal. - After adjustment, separate the LEFT and TOP DECO from the SET. BOLT-ETC (TILT remove) Remove DECO after checking...
  • Page 50 4. FRAME installation and cable connection ⑭ When the ASSY BRACKET P-FRONT installation is complete, fix it with the BRACKET SUPPORT on the left and right sides. - BRACKET-SUPPORT assembly position is generally assembled with top/bottom center 3POINT. (Addable depending on the situation) - After assembling the SCREW-SPECIAL into the BRACKET-SUPPORT, turn it and push the inside.
  • Page 51 Table of contents 1. Product and installation information 2. Preparation of Cabinet installation 3. Wall Mount 4. Frame installation and cable connection 5. Frame Bezel Installation 6. Dehumidification mode guide 7. IP Manual setting Guide ※ Appendix1 - LED MODULE and CIRCUIT replacement method ※...
  • Page 52: Frame Bezel Installation

    5. Frame Bezel Installation ① Install the left and right side bezels first. - Put the FRAME BEZEL SIDE on the left/right side of the CABINET and check if it does not match the screen. - Move the front position according to mismatch and attach it. Check the gap LED R&D Lab(VD)
  • Page 53 5. Frame Bezel Installation ② Install the FRAME BEZEL TOP at the top and screw. M3,L5 M4,L12 - Place the FRAME BEZEL SIDE and FRAME BEZEL TOP/BOTTOM together so that there is no GAP. - The M3 screw enters into TOP/BOTTOM with FRAME BEZEL SIDE, and the M4 screw enters into CABINET. ②.assemble the DECO TOP RIGHT after ①...
  • Page 54 5. Frame Bezel Installation ③ Install FRAME BEZEL BOTTOM at the bottom and screw it. - In the case of the lower part, attach the BEZEL TOP + BEZEL BOTTOM. M3,L5 M4,L12 - When assembling the BEZEL BOTTOM, check the IR SENSOR location and attach it. DECO BOTTOM LEFT DECO BOTTOM RIGHT LED R&D Lab(VD)
  • Page 55: Dehumidification Mode Guide

    Table of contents 1. Product and installation information 2. Preparation of Cabinet installation 3. Wall Mount 4. Frame installation and cable connection 5. Frame Bezel Installation 6. Dehumidification mode guide 7. IP Manual setting Guide ※ Appendix1 - LED MODULE and CIRCUIT replacement method ※...
  • Page 56 This is something that the customer who runs the Dehumidification guide screen should recognize, so please print it out by the installer and deliver it to the customer (user).  If moisture penetrates the LED device, a short circuit in the device may occur in the long term, resulting in a line-type error.
  • Page 57 Dehumidification guide – Manual remote control hidden key A. Definition Dehumidification pattern output start and dehumidification mode end for LED device unit (pixel) dehumidification of LED module are managed. B. Detailed Description 1. In the sleep mode, the hidden key (MUTE → 3 → 7 → 9 → EXIT) enters the dehumidification mode. 2.
  • Page 58 Dehumidification guide – Manual remote control hidden key C. Constraints 1. IR KEY is not processed except for remote control return key while dehumidification mode is in progress 2. During dehumidification mode, AC OFF/ON of the right SYSTEM driver operates according to the "Auto-on" setting value. 3.
  • Page 59 Dehumidification guide - LSM This is something that the customer who runs the screen should recognize, so please print it out by the installer and deliver it to the customer (user).  Installation when dehumidification is required. ※ Do not play or use other content before the instructions on the next page are completed. ※...
  • Page 60 Dehumidification guide – Semi Auto A. Definition The function that allows the product to enter dehumidification mode by turning on the remote control power to the key by grasping the conditions requiring dehumidification B. Detailed Description 1. Factory Option (Control – TheWall Option – Sensor Option – Dehumid Function) 'PWR ON' setting 2.
  • Page 61 Dehumidification guide – Semi Auto C. Constraints 1. IR KEY is not processed except for remote control return key while dehumidification mode is in progress 2. During dehumidification mode, AC OFF/ON of the right SYSTEM driver operates according to the "Auto-on" setting value. 3.
  • Page 62 Dehumidification guide – In use This is something that the customer who runs the screen should recognize, so please print it out by the installer and deliver it to the customer (user).  In-device short circuits due to moisture may also occur during product use. ...
  • Page 63 This is something that the customer who runs the Overcooling condensation screen should recognize, so please print it out by the installer and deliver it to the customer (user).  Condensation may occur when the product surface is cooled too cold compared to the ambient air temperature, or when hot and humid air meets the product surface while the surface is cooled.
  • Page 64 This is something that the customer who runs the Prevention of Condensation by A/C screen should recognize, so please print it out by the installer and deliver it to the customer (user).  Please make sure that the cold wind doesn't directly touch the screen. –...
  • Page 65: Product And Installation Information

    Table of contents 1. Product and installation information 2. Preparation of Cabinet installation 3. Wall Mount 4. Frame installation and cable connection 5. Frame Bezel Installation 6. Dehumidification mode guide 7. IP Manual setting Guide ※ Appendix1 - LED MODULE and CIRCUIT replacement method ※...
  • Page 66: Ip Manual Setting Guide

    7. IP Manual Setting Guide The IAC model Auto IP settings are as follows. (Delivery specification) SYSTEM(SLED) : 192.168.176.50 TCON(Cabinet) : 192.168.176.101 ~ 104 ※ Manual configuration due to IP collision is required when using two or more units using the same network (wired LAN) MAIN(SYSTEM) IP FHD Model TCON IP...
  • Page 67 7. IP Manual Setting Guide ※ Factory mode IP Setting Factory – Control - The Wall Option – MANAGER/NETWORK – SLED IP SETTING SYSTEM(SLED) : 192.168.176.50 -> Write SLED IP toggle when changing TCON(Cabinet) : 192.168.176.101 TCON Group Start IP Configuration Value Sequentially next group + 1 ->...
  • Page 68: Ip Manual Setting Guide

    7. IP Manual Setting Guide ※ Warning Return to Default shipment specification during Factory Reset - SYSTEM(SLED) : 192.168.176.50 - TCON(Cabinet) : 192.168.176.101 ~ 104 LED R&D Lab(VD)
  • Page 69 Thank you.
  • Page 70 Table of contents 1. Product and installation information 2. Preparation of Cabinet installation 3. Wall Mount 4. Frame installation and cable connection 5. Frame Bezel Installation 6. Dehumidification mode guide 7. IP Manual setting Guide ※ Appendix1 - LED MODULE and CIRCUIT replacement method ※...
  • Page 71 Product disassembly method – 1) Screen Desorption 130” MAGNET SCREW ① BEZEL TOP/BOTTOM disassemble : ② BEZEL SIDE disassemble : Magnet desorption ③ BRACKET-SUPPORT disassemble screw disassemble * Decomposition screen storage method Place the EPE PAD on the floor, place the module facing the floor, and assemble the COVER CORNER to prevent damage.
  • Page 72 Disassembly - 2) Docking Station ① Docking Station SMPS SMPS SMPS SMPS AC inlet AC inlet SYSTEM LED R&D Lab(VD)
  • Page 73 Disassembly - 2) Docking Station ② Power Cabling – Harness cable Disassembly Specification Q’ty Code Disassemble the Harness cables connected to the SMPS and the Boards BN39-02838A 1 2 3 BN39-02837A SMPS SMPS SMPS SMPS BN39-02836A AC inlet AC inlet SYSTEM BN39-02309G BN39-02735A...
  • Page 74 Disassembly - 2) Docking Station ② Power Cabling – Harness cable Disassembly Disassemble the Harness cables connected to the SMPS and the Boards Code Specification Q’ty BN39-02839A SMPS BN39-02728A SMPS SMPS SMPS AC inlet AC inlet SYSTE LED R&D Lab(VD)
  • Page 75 Disassembly - 2) Docking Station ③ System Cabling – OCM Cable Disassembly Disassemble the OCM cables connected to System Board Code Specification Q’ty BN39-02743B BN39-02743A SMPS SMPS SMPS SMPS AC inlet AC inlet SYSTEM BN39-02776A LED R&D Lab(VD)
  • Page 76 Disassembly - 2) Docking Station ③ System Cabling – FFC Cable Disassembly Disassemble the FFC cables connected to System Board Code Specification Q’ty Folding,L280,24P BN96-55466A Wrinkle/Straight,L,68P BN96-55465A SMPS SMPS SMPS SMPS AC inlet AC inlet SYSTEM 12 13 LED R&D Lab(VD)
  • Page 77 Disassembly - 2) Docking Station ③ System Cabling – Speaker Cable Disassembly Disassemble the Speaker cables connected to System Board Code Specification Q’ty TV-SPK,IAB,2ch,6ohm,10W BN96-49998H SMPS SMPS SMPS SMPS AC inlet AC inlet SYSTEM LED R&D Lab(VD)
  • Page 78 Disassembly - 2) Docking Station ④ Board and Module Disassembly Disassemble the System, Tray board and Function Module Code Specification Shape Quantity M3 / L5 6001-003016 Total : 10 PWH / ZPC (WHITE) M4 / L6 Total : 2 6001-002610 BH / ZPC (BLACK) M3 / L4 Total : 1...
  • Page 79 Disassembly - 2) Docking Station ⑤ Board Disassembly Disassemble the AC Inlet Board Code Specification Shape Quantity M3 / L5 6001-003016 Total : 8 PWH / ZPC (WHITE) M4 /L6 Total : 2 6001-002789 BH / ZPC (WHITE) 부자재 Code Specification Quantity SMPS...
  • Page 80 Disassembly - 2) Docking Station ⑥ Speaker Disassembly Hook Type : Disassemble without tools LED R&D Lab(VD)
  • Page 81 Disassembly - 2) Docking Station ⑦ SMPS Disassembly Remove the screw 6 points. Code Specification Shape Quantity Remove 1 point of screw on SMPS Bracket-Align M3 / L5 Remove the Bracket-Align PWH / ZPC (WHITE Total : 28 6001-003016 M4 / L6 Total : 12 6001-002610 BH / ZPC (BLACK)
  • Page 82 Disassembly - SMPS ◆ CAUTION : SMPS Discharge Contactable Point : Point that can be touched without the - When contacting or removing SMPS, Use a discharge jig to need for additional discharge check discharge at the two discharging points. Non-Contact Point : Point where touch is not possible without the need for additional discharge...
  • Page 83 Disassembly – 3) Sub Screen ① Sub Screen LED R&D Lab(VD)
  • Page 84 Disassembly – 3) Sub Screen ② TCON, Lower Board Cabling – FFC Cable Disassembly Code Specification Q’ty 15 X 4 BN96- Straight ,L220,51P Total : 60 57481A 6 X 4 BN96- Fold, L190, 51P Total : 24 57485A LED R&D Lab(VD)
  • Page 85 Disassembly – 3) Sub Screen ② TCON, Lower Board Cabling – FFC Cable Disassembly Code Specification Q’ty 3 X 4 BN96- Fold, L370, 51P Total : 12 57482A 3 X 4 BN96- Fold, L420, 51P Total : 12 57483A LED R&D Lab(VD)
  • Page 86 Disassembly – 3) Sub Screen ② TCON, Lower Board Cabling – FFC Cable Disassembly Code Specification Q’ty 2 X 4 BN96- Straight, L240, 68P Total : 8 57484A 1 X 4 BN96- Straight, L240, 96P Total : 4 54937A LED R&D Lab(VD)
  • Page 87 Disassembly – 3) Sub Screen ② TCON, Lower Board Cabling – Harness Cable Disassembly Code Specification Q’ty 9 x 4 BN39-02949A Total : 36 9 X 4 BN39-02951A Total : 36 2 X 4 BN39-02571A Total : 8 LED R&D Lab(VD)
  • Page 88 Disassembly – 3) Sub Screen ④ Tcon, Lower B’d Disassembly Code Specification Shape Quantity M3 / L5 18 x 4 6001-003016 PWH / ZPC (WHITE) Total : 72 LED R&D Lab(VD)
  • Page 89 Product disassembly method – 4) LED module replacement □ Module disassemble ※ Cautions when disassembling modules When replacing the module, make sure to proceed with the AC power cable unplugged. Since this product cannot be serviced from the front, make sure to disassemble the module with the cabinet separated.
  • Page 90 Product disassembly method – 4) LED module replacement □ Module disassemble back Direction of disassemble front Back view Raise about 1mm. ④ Carefully push the modules on both sides in the side direction with your hands based on the ⑤ Based on the module you want to remove, modules you are trying to remove push the module at the top upward from the ⑥...
  • Page 91 Product disassembly method – 4) LED module replacement □ Module disassemble Back view Back view Front view separte pin cable ※ When pushing the module, support the module in front so that there is no excessive tension between the module and the cable. Avoid excessive tension DON`t separate FFC cable Check the cable location of module you...
  • Page 92 Product disassembly method – 4) LED module replacement □ Module assemble If you can`t assemble the module because of weak magnet force, Please follow the step. magnet module magnet Insert driver and push magnet Assemble the new module in the removed module space module LED R&D Lab(VD)
  • Page 93 Product disassembly method – 4) LED module replacement □ Module assemble Assemble the new module in the removed From the module just above the assembled Based on the assembled module, collect the module space module, lower it down in order. modules on both sides in the middle LED R&D Lab(VD)
  • Page 94 Product reassembly method – 1) LED module step control □ Module assembly HOLDER-PCB Assemble the removed HOLDER-PCB material back into the Assemble the cable in the new module. cabinet. (If you have disconnected the board, assemble it back to its original state) ※Caution!: There is a possibility of module departure due to pressing force when assembling cable.
  • Page 95 Product reassembly method – 1) LED module Z step control □ Module Z step control • Clockwise: The direction in which the module appears toward the screen • Counterclockwise: The direction in which the module enters. - Driver or hand rotation Case) Module height is low Module moving direction...
  • Page 96 Reassembly – 2) Sub Screen □ Sub Screen ※ Assembly is the reverse order of Disassembly. ② Assemble FFC ① Assemble TCON, Lower ③ Assemble FFC, Harness ④ Final completion LED R&D Lab(VD)
  • Page 97 Reassembly – 3) Docking Station □ Docking Station ※ Assembly is the reverse order of Disassembly. ④ Assemble the FFC cable and ③ Assemble the Speaker. ① Assemble SMPS, AC inlet ② Assemble System, Tray Harness cable, OCM cable board, Module LED R&D Lab(VD)
  • Page 98 Product reassembly method – 4) Screen attachment □ Screen attachment Hang the top of the FRONT first and then attach the bottom.. Handle fastening method (decomposition method is in reverse order) Handle inserted on the Handle fastening toward Handle fastening side of the frame the top of the screen completed...
  • Page 99 Product reassembly method – 5) screen seam control □ Seam control between sub screens (X) After removing the BEZEL, the gap between SCREENs can be adjusted by using SCREW to adjust the height difference, tilt between SCREENs. LED R&D Lab(VD)
  • Page 100 Product reassembly method – 5) Sub screen seam control □ Seam control between sub screens (X)_2 You can adjust the X-axis step using the structure and drivers between screens. LED R&D Lab(VD)
  • Page 101 Product reassembly method – 5) Sub screen seam control □ Seam control between sub screens (Y) Insert a 3 mm hexagonal wrench into the screw Counterclockwise rotation: Screen downward movement Clockwise rotation: Screen upward movement After removing BEZEL, you can adjust the height difference, tilt between SCREENs with SCREEN top SCREW.
  • Page 102 Product reassembly method – 5) Sub screen seam control □ Seam control between sub screens (Z) Spread between SCREENs and adjust the Z step using DRIVER. LED R&D Lab(VD)
  • Page 103 Table of contents 1. Product and installation information 2. Preparation of Cabinet installation 3. Wall Mount 4. Frame installation and cable connection 5. Frame Bezel Installation 6. Dehumidification mode guide 7. IP Manual setting Guide ※ Appendix1 - LED MODULE and CIRCUIT replacement method ※...
  • Page 104 SVC – System Main / TCON / LED Module Update data on replacement Proceed all data updates in order □ System Main Board - Option ① Type : 130IAC2K Local Set : Set according to the model ② ③ SW Model : IABH ④...
  • Page 105 SVC – System Main / TCON / LED Module Update data on replacement Proceed all data updates in order □ TCON Board Replacing Replace the TCON board with defect -> Follow the guide below and update the data(Factory data, Gamma data) LED R&D Lab(VD)
  • Page 106 SVC – System Main / TCON / LED Module Update data on replacement Proceed all data updates in order □ TCON Board Replacing ① To check the ID Number of TCON Board - Set the SHOW ID ON -> Check the TCON Board ID Number ②...
  • Page 107 Table of contents 1. Product and installation information 2. Preparation of Cabinet installation 3. Wall Mount 4. Frame installation and cable connection 5. Frame Bezel Installation 6. Dehumidification mode guide 7. IP Manual setting Guide ※ Appendix1 - LED MODULE and CIRCUIT replacement method ※...
  • Page 108 Product and installation information Side Link Kit (Side By Side extension kit) VG-IACNS3*** ◆ Model specification - This manual is an installation manual for IAC SIDE LINK KIT Model Product appearance and information IAC series SIDE LINK KIT IAC Series : Package Type / 60Hz Refresh Rate REMARK P1.5 (130”) Maximum Linkable Screens : 4...
  • Page 109 SIDE LINK KIT Assemble Exploded view and Part List ITEM FIGURE 130" ASSY BRACKET P-SIDE LINK KIT BRACKET-FRAME SIDE LINK BRACKET-LINK BRACKET-LINK SHORT SCREW (BH,+,M4,L8) SCREW (FH,+,-,M4,L6) SCREW (FH,+,-,M3,L5) BRACKET-LINK LEAFLET-QUICK SETUP GUIDE LED R&D Lab(VD)
  • Page 110 Frame Installation and Side Link connection ① Join LEAFLET-WALL MOUNT to extended size - Join original LEAFLET-WALL MOUNTs using LEAFLET-LINK side to side (* Same with combine 3 or max 4 screens) SET 1 SET 2 Overlapping and attaching the area marked "SIDE LINK KIT" LED R&D Lab(VD)
  • Page 111 Frame Installation and Side Link connection Install the wall mount on the wall (using joined LEAFLET-WALL MOUNT) ② - Attach the joined LEAFLET to the wall to locate the wall mount Fig.2 using the screw - Check the horizontal state using a laser leveler - Fix the left and right two points to the wall using the included screw.
  • Page 112 Frame Installation and Side Link connection ③ After hanging the ASSY COVER P-REAR, remove the BRACKET-PLATE. - Refer to the existing installation manual and mount the ASSY COVER P-REAR on the installed wall mount Unscrew 2EA to remove. - Remove 3 TOP points and 1 BOT point for each RIGHT/LEFT part. * Refer to the figure below BRACKET-PLATE removing point Figure 2 TOP Part: BRACKET-PLATE Remove each 3EA left and right BRACKET-PLATE removing point...
  • Page 113 Frame Installation and Side Link connection ③-1 Connect ASSY COVER P-REAR using BRACKET-LINK - Connect the ASSY BRACKET P-FRAME of the connection using BRACKET-LINK (FH,M4,L6 screws) Fig.2 Combine ASSY COVER P-REAR L/R TOP side with BRACKET-LINK Fig.1 Install ASSY COVER P-REARs on wall (example) Fig.3 Combine ASSY COVER P-REAR L/R BOT side with BRACKET-LINK SHORT LED R&D Lab(VD)
  • Page 114 Frame Installation and Side Link connection ③-2 Connect the ASSY BRACKET P-FRAME to the BRACKET-FRAME SIDE LINK. - Remove both BRACKET-SHAFT and GASKET-EMI from the connection area after BRACKET-LINK assembly (disposal) - Assemble the T bar-shaped BRACKET-FRAME SIDE LINK on the connection (BH,M4,L8 screws) BRKT-FRAME SIDE LINK BRACKET SHAFT GASKET-EMI...
  • Page 115 Cover-Decoration(BEZEL) Assembly Finish installation with COVER-DECORATION (BEZEL) ④ - After Installation Screens and adjust XY seam and z mismatch, Finish installation with assemble Cover-Deco(BEZEL) - Join COVER-DECO TOP and BOT with BRACKET-LINK (FH,M3,L5 Screws) Fig.1 Install C/DECO Fig.2 Joining C/DECO TOP/BOT Unused C/DECO L/R ->...
  • Page 116 * Wall mount position * Combined Wall mount position - Despite using combined LEAFLET-WALL MOUNT, To check wall mount position exactly, check with below Wall mount position (Standard Tolerance +-1.0 mm) LINK area Screen 1 Screen 2 Fig.1 130” 4 Screens(maximum) Bracket-wall position LED R&D Lab(VD)
  • Page 117 Screen Settings for Side by Side Installation □ Side by Side Configuration Notice ■ If one source equipment is connected and used, use a separate signal distribution equipment or wall controller ※ In order to optimize image sync, it is recommended to synchronize the output sync of the source equipment and use the same fps.
  • Page 118 Screen Settings for Side by Side Installation □ Side by Side Installation Method Install four IAB/IAC sets side by side from side and connect the video source (HDMI) When activating the LED HDR function, 3.5pi stereo cable connection is required to match the brightness between the two sets as shown in the figure below IAB/IAC set 1 IAB/IAC set 2...
  • Page 119 Set up screen when installing Side by Side, Method 1 – Remote Control □ Settings for each SET Remote Control button – Video Wall – Video Wall ‘on’ Remote Control button – Picture - Picture mode – ‘Calibration’ ※ Sync between screens may be twisted when switching to screen mode in expert adjustment mode and video wall mode ON state.
  • Page 120 Set up screen when installing Side by Side, Method 1 – Remote Control □ Settings for each SET (HDR) Remote Control button – Picture – LED HDR – Dynamic Peaking – ‘HIGH’ or ‘MID’ or ‘LOW’ Remote Control button – Picture – LED HDR – Multi-Link HDR Settings – Multi-Link HDR On / Number of Devices / Device ID ※...
  • Page 121 Set up screen when installing Side by Side, Method 1 – Remote Control □ Screen Split Scenario Displays each source from an external device ※ Pre-work : ON the video wall function of the SET (Remote Control button – Video Wall – Video Wall ‘on’) IAB/IAC set 1 IAB/IAC set 2 IAB/IAC set 3...
  • Page 122 Set up screen when installing Side by Side, Method 2 – LSM If there is a SET setting with the same IP □ Settings for each SET in the network, IP conflict may occur ① Setting IP 1) Setting PC - 192.168.176.XXX Fixed IP setting required 3) Ethernet right-click >...
  • Page 123 Set up screen when installing Side by Side, Method 2 – LSM If there is a SET setting with the same IP □ Settings for each SET in the network, IP conflict may occur ① Setting IP 2) Setting SET - Use the remote control to configure the IP according to the scenario below.
  • Page 124 Set up screen when installing Side by Side, Method 2 – LSM If there is a SET setting with the same IP □ Settings for each SET in the network, IP conflict may occur ① Setting IP 2) Setting SET - Ex) Setting IP for 4 SETs Connections ※...
  • Page 125 Set up screen when installing Side by Side, Method 2 – LSM If there is a SET setting with the same IP □ Settings for each SET in the network, IP conflict may occur ② IP connection in LSM Case 1) Write SLED IP Success, Write Cabinet IP Success Case 1 Write SLED IP - Success 2) Model type ‘All In One’...
  • Page 126 Set up screen when installing Side by Side, Method 2 – LSM If there is a SET setting with the same IP □ Settings for each SET in the network, IP conflict may occur ② IP connection in LSM Case 2) Write SLED IP Success, Write Cabinet IP Ready 2) Model type ‘All In One’...
  • Page 127 Set up screen when installing Side by Side, Method 2 – LSM If there is a SET setting with the same IP □ Settings for each SET in the network, IP conflict may occur ② IP connection in LSM Case 3) Select device search function in LSM is used Case 3 If you use the device search function in the 2) Model type ‘All In One’...
  • Page 128 Set up screen when installing Side by Side, Method 2 – LSM □ Settings for each SET ③ Enable Multi Link function by Grouping ※ In LSM, frame lock function and multi link HDR function are set through grouping, but if split output is required by entering the same source into multiple IAB/IAC, the screen position of the videowall needs to be set through OSD.
  • Page 129 Table of contents 1. Product and installation information 2. Preparation of Cabinet installation 3. Wall Mount 4. Frame installation and cable connection 5. Frame Bezel Installation 6. Dehumidification mode guide 7. IP Manual setting Guide ※ Appendix1 - LED MODULE and CIRCUIT replacement method ※...
  • Page 130 LSM Connection – 1) Wired Wired connection IP Address Setting 192 . 168 . 176 . → IAC SET IP ‘50’ is the default setting, During Multi Screen scenario, ID:3 it can be changed. 192 . 168 . 176 . →...
  • Page 131 LSM Connection – 1) Wired LSM Program setting ① Enter IAC SET’s IP > ‘Add’ Click ‘All In One’ ② Set Model type ‘Connect’ Click LED R&D Lab(VD)
  • Page 132 LSM Connection – 2) Wireless 1) Set Factory Setting Wireless connection ① ② ③ ID:3 ID:2 ⑤ ④ 192.168.176.104 192.168.176.103 192.168.176.102 192.168.176.101 WI-FI DIRECT ※ LSM Connection Factory mode -> Control -> The Wall Option -> MANAGER/NETWORK -> LSM CONNECTION LED R&D Lab(VD)
  • Page 133 LSM Connection – 2) Wireless 2) Notebook WI-FI setting 3) LSM Program setting ② Enter IAC SET’s IP > ‘Add’ Click ‘All In One’ ③ Set Model type ‘Connect’ Click ① IAC SET connection in Notebook WI-FI Setting (PW : samsungwall) LED R&D Lab(VD)
  • Page 134 LSM Connection – Control screen when connection is complete < Cabinet unit Control screen > < Whole SET Control screen > LED R&D Lab(VD)
  • Page 135 Table of contents 1. Product and installation information 2. Preparation of Cabinet installation 3. Wall Mount 4. Frame installation and cable connection 5. Frame Bezel Installation 6. Dehumidification mode guide 7. IP Manual setting Guide ※ Appendix1 - LED MODULE and CIRCUIT replacement method ※...
  • Page 136 Appendix. Gradation Calibration - SSA Calibration 종류 Mobile Support specification Support Model : S10/Note10, S20, 21, 22 Series (except basic model of S21, S22) Special Model(Flips etc.) are not supported LED R&D Lab(VD)
  • Page 137 Gradation Calibration - SSA Calibration 종류 Mobile calibration Cal reader Common : Notebook Tripod LAN Cable Preparations Mobile phone WIFI router (of USB-C to LAN gender) AAE / JMU / RAF CS4B / CV4B IFH/IER/IFR/IEA/IFA Support IWA / IWB / IWC / IVC IFH/IER/IFR/IEA/IWJ/IWR/IWA Model (All-in-One) IAB / IAC...
  • Page 138 Gradation Calibration - SSA Mobile Solution IP Address Setting - Module unit 192 . 168 . 176 . → IAC - Color correction after module replacement [ Adjustment target screen ] 192 . 168 . 176 . → notebook ID:3 192 .
  • Page 139 Gradation Calibration - SSA Preparation work MCE2 -. IP configuration of WIFI router and IAC -. Check if the layout of all cabinets is normal in LSM -. Install SSA (Signage Setup Assistant) app Download Play Store – Install SSA (Signage Setup Assistant) LED R&D Lab(VD)
  • Page 140 Gradation Calibration - SSA External network connection guide will be updated in the future. [ Mobile Setting Method ] [ IAC Setting Method ] Connection between IAC and WiFi Direct Factory – Control – The Wall Option – ex) DIRECT-D7Samsung IAC Series MANAGER/NETWORK - LSM WIFI CONNECTION Password : samsungwall →...
  • Page 141 Gradation Calibration - SSA External network connection guide will be updated in the future. 1. When connecting WIFI Direct, only one 4. Press Next when you see the selected model IAC device appears when you click Search 5. Select Select Select model type All In One (※The list of devices connected to the AP is displayed when an external AP is connected.) 2.
  • Page 142 Gradation Calibration - SSA External network connection guide will be updated in the future. 6. If selected as All In One, 4 connected 8. If you check Device Info IAC and press cabinet groups are automatically allocated Next, you can control it like LSM by pressing (If you uncheck Connect with Existing Connection Completed Done Settings, you can manually configure IP.)
  • Page 143 Gradation Calibration - SSA Press the upper right button to select and control test patterns When selecting calibration in All Settings, it can be adjusted the same as LSM. Cabinet unit and module unit can be adjusted. LED R&D Lab(VD)
  • Page 144 Gradation Calibration - SSA Calibration function will be updated when SSA development is completed. Scheduled after September LED R&D Lab(VD)
  • Page 145 Table of contents 1. Product and installation information 2. Preparation of Cabinet installation 3. Wall Mount 4. Frame installation and cable connection 5. Frame Bezel Installation 6. Dehumidification mode guide 7. IP Manual setting Guide ※ Appendix1 - LED MODULE and CIRCUIT replacement method ※...
  • Page 146 Appendix Framelock Mode(Video Wall Mode “ON” + Picture Mode “Calibration”) Supported Timing List(HDMI/DP) LH015IAC (2K) LH016IAB / LH012IAB(2K) LH008IAB(4K) 640x480 59.94Hz 640x480 59.94Hz 640x480 59.94Hz 720x480 59.94Hz 720x480 59.94Hz 720x480 59.94Hz 720x576 50Hz 720x576 50Hz 720x576 50Hz 1280x720 50/60Hz 1280x720 50/60Hz 1280x720 50/60Hz 1280x800 59.810Hz 1280x800 59.810Hz...

This manual is also suitable for:

Lh015iac series

Table of Contents