1
12.8 The inlet hose filter and
the valve filter
It could be necessary to clean the filters
when:
• The appliance does not fill with water.
• The appliance fills with the water for a
long time.
2
3.
Put a container below the recess of
the drain pump to collect the water
that flows out.
4.
Press the two levers and pull for-
ward the drainage duct to let the
water flow out.
5.
When the container is full of water,
put the drainage duct back again
and empty the container. Do steps 4
and 5 again and again until no more
water flows out from the drain
pump.
6.
Pull back the drainage duct and turn
the filter to remove it.
7.
Remove fluff and objects from the
pump.
8.
Make sure that the impeller of the
pump can turn. If this does not oc-
cur, contact the service centre.
9.
Clean the filter under the water tap
and put it back in the pump into the
special guides.
10.
Make sure that you tighten correctly
the filter to prevent leakages.
11.
Put the flap back and close the drain
pump door.
• The indicator of button
the display shows the related alarm.
Refer to 'Troubleshooting'.