Honeywell NOTIFIER FCM-1A Installation And Maintenance Instructions

Honeywell NOTIFIER FCM-1A Installation And Maintenance Instructions

Supervised control module

Advertisement

Quick Links

INSTALLATION AND MAINTENANCE INSTRUCTIONS
FCM-1A Supervised Control Module
SPECIFICATIONS
Normal Operating Voltage:
Maximum Current Draw:
Average Operating Current:
Maximum Line Loss on NAC (Notification Appliance Circuit)/
SOC (Signaling Output Circuit):
External Supply Voltage (between Terminals T10 and T11)
Maximum (NAC/SOC):
Maximum (Speakers):
Drain on External Supply:
Max NAC/SOC Current Ratings:
Temperature Range:
Humidity:
Dimensions:
Accessories:
POWER INPUT/OUTPUT RATINGS
CURRENT RATING
2 A
3 A
2 A
0.46 A
0.7 A
0.9 A
0.5 A
0.3 A
BEFORE INSTALLING
This information is included as a quick reference installation guide. Refer to
the control panel installation manual for detailed system information. If the
modules will be installed in an existing operational system, inform the opera-
tor and local authority that the system will be temporarily out of service. Dis-
connect power to the control panel before installing the modules.
NOTICE: This manual should be left with the owner/user of this equipment.
GENERAL DESCRIPTION
FCM-1A Supervised Control Modules are intended for use in intelligent, two-
wire systems, where the individual address of each module is selected using
the built-in rotary switches. This module is used to switch an external power
supply, which can be a listed, regulated, supervised, power-limited DC power
supply or an audio amplifier (up to 80 VRMS), to notification appliances. It
also supervises the wiring to the connected loads and reports their status
to the panel as NORMAL, OPEN, or SHORT CIRCUIT. The FCM-1A has
two pairs of output termination points available for fault-tolerant wiring and a
panel-controlled LED indicator. This module can be used to replace a CMX-2
module that has been configured for supervised wiring operation.
COMPATIBILITY REQUIREMENTS
To ensure proper operation, this module shall be connected to a compatible
NOTIFIER system control panels only (list available from NOTIFIER).
MOUNTING
The FCM-1A mounts directly to 4-inch square electrical boxes. (See
Figure 2A.) The box must have a minimum depth of 2
Surface mounted electrical boxes (SMB500 Series) are available. The module
can also mount to the DNRA / DNRW duct housing.
15 to 32 VDC
6.5 mA (LED on)
375µA (LED flashing - in group poll mode); 350µA (LED flashing - in direct poll mode);
485µA Max. (LED flashing, NAC/SOC shorted)
4 VDC
Regulated 24 VDC
70.7 V RMS, 50 W
1.7 mA Maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply
For DCLB (class B) wiring system, the current rating is 3A; For DCLA (class A) wiring system, the current rating is 2A
32°F to 120°F (0°C to 49°C)
10% to 93% Non-condensing
4.675" H x 4.275" W x 1.4" D (119 mm H x 108 mm W x 36 mm D)
Mounts to a 4" square (102 mm) by 2
SMB500 Series Electrical Box; CB500 Barrier
MAXIMUM VOLTAGE
25 VAC
30 VDC
30 VDC
30 VDC
70.7 VAC
125 VDC
125 VAC
125 VAC
1
/
inches (54 mm).
8
1
/
" (54 mm) deep box.
8
LOAD DESCRIPTION
PF = 0.35
Resistive
Resistive, NAC/SOC, and Door Holder
(L/R = 20ms)
PF = 0.35
Resistive
PF = 0.75
PF = 0.35
WIRING
NOTE: All wiring must conform to applicable local codes, ordinances, and
regulations. The CB500 Module Barrier must be used to meet ULC require-
ments for the separation of extra-low-voltage and low-voltage terminals and
wiring. The barrier must be inserted into a 4" × 4" × 2
× 54 mm) junction box, and the control module must be placed into the bar-
rier and attached to the junction box. (See Figure 2A.) The extra-low-voltage
wiring must be placed into the isolated quadrant of the module barrier. (See
Figure 2B.)
1.
Install module wiring in accordance with the job drawings and appropri-
ate wiring diagrams.
2.
Set the address on the module per job drawings.
3.
Secure module to electrical box (supplied by installer). (See Figure 2A.)
Wire should be stripped to the appropriate length (recommended strip length
is
1
/
" to
3
/
") (6 mm to 10 mm). Exposed conductor should be secured under
4
8
the clamping plate and should not protrude beyond the terminal block area.
CAUTION: Do not loop wire under terminals. Break wire run to provide super-
vision of connections.
IMPORTANT: When using the FCM-1A for audio applications, remove
Jumper (J1) and discard. The Jumper is located on the back as shown in
Figure 1B.
J1 must be removed whenever power supply monitoring feature is not required.
1
12 Clintonville Road
Northford, CT 06472-1653
Phone: 203.484.7161
APPLICATION
Non-coded
Non-coded
Coded
Non-coded
Non-coded
Non-coded
Non-coded
Non-coded
1
/
" (102 mm × 102 mm
8
I56-3187-003
4/20/2023

Advertisement

loading

Summary of Contents for Honeywell NOTIFIER FCM-1A

  • Page 1 INSTALLATION AND MAINTENANCE INSTRUCTIONS 12 Clintonville Road FCM-1A Supervised Control Module Northford, CT 06472-1653 Phone: 203.484.7161 SPECIFICATIONS Normal Operating Voltage: 15 to 32 VDC Maximum Current Draw: 6.5 mA (LED on) Average Operating Current: 375µA (LED flashing - in group poll mode); 350µA (LED flashing - in direct poll mode); 485µA Max.
  • Page 2 FIGURE 1A. CONTROLS AND FIGURE 1B. JUMPER LOCATION FIGURE 2A. MODULE MOUNTING FIGURE 2B INDICATORS WITH BARRIER C1059-00 C0910-00 C1070-00 FIGURE 3. TYPICAL NOTIFICATION APPLIANCE CIRCUIT CONFIGURATION, DCLB (NFPA CLASS B) 24 VDC CIRCUIT Connect modules to listed Do not loop wire on Terminals 10 & 11. compatible control panels only.
  • Page 3 FIGURE 4. TYPICAL FAULT TOLERANT NOTIFICATION APPLIANCE CIRCUIT CONFIGURATION, DCLA (NFPA CLASS A) 24 VDC CIRCUIT Connect modules to listed Do not loop wire on Terminals 10 & 11. compatible control panels only. Break wire run to provide supervision of connections. 24 VDC NAC/SOC output —...
  • Page 4 FlashScan ® , NOTIFIER ® , System Sensor ® , and Honeywell ® are registered trademarks of Honeywell International, Inc. I56-3187-003 ©2023 NOTIFIER. 4/20/2023...