Bosch B430 - Plug-in Telephone Communicator Installation Guide

Bosch B430 - Plug-in Telephone Communicator Installation Guide

Also See for B430:

Advertisement

Bosch B430 - Plug-in Telephone Communicator Installation Guide

Overview

Overview
Figure 1.1: Module overview

The B430 Plug-in Telephone Communicator provides communication over the PSTN (Public Switched Telephone Network) by directly connecting the module to the control panel. The module provides a single telephone jack and easily installs into an on-board connector.

You can program, diagnose, and troubleshoot the system from the control panel keypad as well as remotely through RPS.

Callout ― Description
1 ― Module handle and support leg
2 ― Line seize/ring LED
3 ― Test phone pads
4 ― RJ45 phone connector
5 ― Plug-in module retention clip opening
6 ― PCB metal contacts

Install or remove the module

warning NOTICE! Remove all power (AC and battery) before making any connections. Failure to do so might result in personal injury and/or equipment damage.

Install the module

Install the module
Figure 2.1: Module installation

The control panel communicates with and provides power to the module through the plug-in connection. Proper installation results in the necessary electrical and mechanical connection.

Installing the module:

  1. With the module facing the control panel as shown below, insert the support leg into the support hole labeled X.
  2. Align the PCB metal contacts with the on-board connector.
  3. Push the module into place. The retention clip snaps closed and secures the module in place.
Callout ― Description
1 ― Support leg inserted into the control panel support hole labeled X
2 ― PCB metal contacts resting on the on-board connector
3 ― Plug-in module retention clip

Wire the module

Wire the module
Figure 2.2: Wiring the module

Connect one end of a compatible telephone cord to the B430, and connect the other end to an RJ31X or RJ38X phone jack that is connected to the phone line. The module has pads on both sides of the board to connect a telephone test set. Refer to Figure 2.2.

Callout ― Description
1 ― Premises telephone
2 ― Incoming Telco line
3 ― Installer telephone test set
4 ― RJ45 phone connector

Remove the module

To remove an installed module, hold the plug-in module retention clip open with one hand while grasping the top corners of the module support handle with your other hand. Pull the module out.

LED descriptions

The module uses a green LED to indicate when the circuit is on or off the hook or the phone line is ringing. Refer to Table 3.1.

Flash pattern Function
OFF Steady
Standby
ON Steady
Line seize
Flash
__
Ring detect

Table 3.1: Diagnostic LED flash patterns

Configuration

Use Remote Programming Software (RPS) or an SDI2 keypad to program the control panel to use the module for communication.
For programming parameter descriptions, options, and defaults refer to RPS Help or the Program Entry Guide for your control panel.

Certifications

Region Certification
US UL 365 - Police Station Connected Burglar Alarm Units and Systems
UL 636 - Holdup Alarm Units and Systems
UL 864 - Control Units and Accessories for Fire Alarm Systems (Commercial Fire)
UL 985 - Household Fire Warning System Units
UL 1023 - Household Burglar Alarm System Units
UL 1076 - Proprietary Burglar Alarm Units and Systems
UL 1610 - Central Station Burglar Alarm Units
FCC Part 15
FCC Part 68 FCC Registration Number: ESVAL00BB430
Ringer Eq: 0.0B
Canada CAN/ULC S303 - Local Burglar Alarm Units and Systems
CAN/ULC S304 - Signal Receiving Centre and Premise
CAN/ULC S545 - Residential Fire Warning System Control
ICES-003 - Information Technology Equipment (ITE)
ULC-ORD C1023 - Household Burglar Alarm System Units
ULC-ORD C1076 - Proprietary Burglar Alarm Units and System

Specifications

Dimensions 2 in x 3.68 in x 0.60 in
(50 mm x 93.5 mm x 15.25 mm)
Voltage (operating) 12 VDC nominal
Current (maximum) Standby: 24 mA Alarm: 24 mA
Operating temperature +32°F to +120°F (0°C to +49°C)
Relative humidity 5% to 93% at +90°F (+32°C )
Communication speed 2400 baud maximum
Compatibility B9512G/B9512G-E
B8512G/B8512G-E
B5512/B5512E
B4512/B4512E
B3512/B3512E

Copyright
This document is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved.

Trademarks
All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.

Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to the Bosch Security Systems, Inc. website at http://www.boschsecurity.com/datecodes/.

www.boschsecurity.com

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Bosch B430 - Plug-in Telephone Communicator Installation Guide

Advertisement

Need Assistance?

Do you have a question about the B430 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents