3. FUNCTION  
The machine is designed for vacuuming and separating dry, non-combustible dust with an
3
explosion limit value of >0.1mg/m
.
The dust extractor is started by the green button on the electrical cabinet, it is stopped by pressing the red button
that is located directly below the start button.
Note:
If the red lamp between the red and green buttons light up. There is a phase error. Switching two of the phases
will solve this issue. This is a safety measure to ensure that the pump doesn't start to blow air instead.
Dust-laden air is then sucked through the inlet valve at high speed via the suction hose. The air is slowed down
by the cyclone and coarse dust particles are separated out, partly by centrifugal force and partly by gravity. Air
and finer particles then pass through the double filter system where separation is made. The machine is designed
for filter cleaning by reverse air pulse.
The separated dust accumulates in the cyclone until the machine is switched off, when it drops through the
bottom flap into the plastic bag. The filter cleaning process is not completed before it is clear that the dust inside
the tank has fallen down into the collection bag. In some extreme cases the adhesive ability of the dust must be
broken manually. This can be done by hitting the dust through the bag or tapping the tank using i.e. a rubber
hammer.