Samsung HARMAN AMX MU Series Instruction Manual

Samsung HARMAN AMX MU Series Instruction Manual

Automation controllers

Advertisement

Quick Links

Instruction Manual
MU-Series Automation Controllers
pg. 1

Advertisement

Table of Contents
loading

Summary of Contents for Samsung HARMAN AMX MU Series

  • Page 1 Instruction Manual MU-Series Automation Controllers pg. 1...
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS ESD Warning To avoid ESD (Electrostatic Discharge) damage to sensitive components, make sure you are properly grounded before touching any internal materials. When working with any equipment manufactured with electronic devices, proper ESD grounding procedures must be followed to make sure people, products, and tools are as free of static charges as possible.
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS READ these instructions. KEEP these instructions. HEED all warnings. FOLLOW all instructions. DO NOT use this apparatus near water. CLEAN ONLY with dry cloth. DO NOT block any ventilation openings. Install in accordance with the manufacturer's instructions. DO NOT install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  • Page 4 WARNING: To reduce the risk of fire or electrical shock, do not expose this apparatus to rain or moisture. WARNING: No naked flame sources – such as lighted candles – should be placed on the product. CAUTION: To be installed by instructed, or skilled, persons only. WARNING: This product is intended to be operated ONLY from the voltages listed on the back panel or the recommended, or included power supply of the product.
  • Page 5 FCC AND CANADA EMC COMPLIANCE INFORMATION: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 6 ENVIRONMENTAL: 该设备的设计和测试是在海拔 2000 米高度以下进行的, 它只适用在海拔2000 米以下的地区. 在海拔2000 米以 上使用可能会导致潜在的安全隐患. This device is designed and evaluated under the condition of altitude below 2000 meters above sea level; it can only be used in locations below 2000 meters above sea level. Using the device above 2000 meters could result in a potential safety hazard.
  • Page 7 EU COMPLIANCE INFORMATION: Hereby, Harman Professional, Inc. declares that the equipment type MU-1000/1300/2300/3300 is in compliance with the following: European Union Low Voltage Directive 2014/35/EU; European Union EMC Directive 2014/30/EU; European Union Restriction of Hazardous Substances Recast (RoHS2) Directive 2011/65/EU and as amended by 2015/863; full text declaration...
  • Page 8: Table Of Contents

    Table of Contents Contents IMPORTANT SAFETY INSTRUCTIONS TABLE OF CONTENTS WHAT’S NEW? UPPORTS MULTIPLE ARMAN PROTOCOLS NATIVELY ONTROL TANDARD ANGUAGE CRIPTING UPPORT ODULE AND RIVER ESIGN ODULE SUPPORT USB H USB-C P ROGRAM ICSL AN IMPROVEMENTS FEATURES MU-S ERIES ONTROLLER EATURES MU-1000 MU-1000 S...
  • Page 9 FRONT PANEL COMPONENTS ROGRAM USB P ENERAL TATUS ICSLAN LED SERIAL LED RELAYS LED IR/SERIAL LED I/O LED WIRING AND CONNECTIONS VERVIEW ERIAL ORTS RS-232 P ORTS ELAY ORTS I/O P ORTS IR/SERIAL P ICSLAN P ORTS ICSLAN N SING THE ETWORK ICSL ETWORK...
  • Page 10: What's New

    What’s New? Supports multiple Harman protocols natively The MU-series controller speaks HControl, HiQnet, and ICSP right out of the box, allowing seamless integration with existing Harman gear. AMX touch panels, Crown DCi Amplifiers, BSS Contrio keypads and Soundweb London devices are all available to the controller from these communication buses.
  • Page 11: Features

    Features MU-Series Controller Features Name (SKU) Features MU-1000 (AMX-CCC000) PoE Powered (802.3af – standard power) 1 LAN Ethernet port 1 ICSLan Control Network port Small form factor – 1” x 5” x 5” DIN Rail mountable with DIN Rail Clip (AMX-CAC0001) 4 GB DDR3 RAM 8 GB eMMC Storage 2x USB 2.0 Type A Host port...
  • Page 12: Mu-1000 Specifications

    MU-1000 The MU-1000 (AMX-CCC000) has 4 GB of on-board DDR3 RAM, a commercial grade 8GB eMMC non-volatile memory storage chip and an ICSLan control network. It is PoE powered and has a small form factor for easy installation. It features the MUSE scripting engine which supports a variety of standard programming languages to create the business logic for the control system.
  • Page 13 …MU-1000 specifications continued ICSLan Port RJ-45 10/100 BASE-T for Ethernet communication Auto MDI/MDI-X DHCP server Provides isolated control network USB Host Port 2x Type-A USB host port USB Mass Storage – for external logging • FLIRC – IR Receiver for IR hand control input •...
  • Page 14: Mu-1300 Specifications

    MU-1300 The MU-1300 (AMX-CCC013) has 4 GB of on-board DDR3 RAM, a commercial grade 8GB eMMC non-volatile memory storage chip and an ICSLan control network. It is a small form factor for easy installation. It features the MUSE scripting engine which provides a variety of standard programming languages to create the business logic for the control system. A complete list of device specifications is listed below.
  • Page 15 …MU-1300 specifications continued P1 / P2 LED Programmable LEDs available to control scripts Serial TX / RX LED Activity LEDs for each port in each direction. Blinks on activity. IR TX LED Activity LEDs for the IR/Serial port. Blinks on transmission. I/O LED LED indication of I/O Status.
  • Page 16: Mu-2300 Specifications

    MU-2300 The MU-2300 (AMX-CCC023) has 4 GB of on-board DDR3 RAM, a commercial grade 8GB eMMC non-volatile memory storage chip and an ICSLan control network. It is built for installing in an equipment rack. It features the MUSE scripting engine which provides a variety of standard programming languages to create the business logic for the control system. A complete list of device specifications is listed below.
  • Page 17 …MU-2300 Specifications continued Rear Panel Components Power 3.5mm Phoenix 2-pin connector with retention screws for 12vdc input LAN Port RJ-45 10/100 BASE-T for Ethernet communication Auto MDI/MDI-X DHCP Client ICSLan Port RJ-45 10/100 BASE-T for Ethernet communication Auto MDI/MDI-X DHCP server Provides isolated control network RS-232/422/485 Port 1 3.5mm Phoenix 10-pin connector...
  • Page 18: Mu-3300 Specifications

    MU-3300 The MU-3300 (AMX-CCC033) has 4 GB of on-board DDR3 RAM, a commercial grade 8GB eMMC non-volatile memory storage chip and an ICSLan control network. It is built for installation in an equipment rack. It features the MUSE scripting engine which provides a variety of standard programming languages to create the business logic for the control system.
  • Page 19 …MU-3300 Specifications continued Rear Panel Components Power 3.5mm Phoenix 2-pin connector with retention screws for 12vdc input LAN Port RJ-45 10/100 BASE-T for Ethernet communication Auto MDI/MDI-X DHCP Client ICSLan Port RJ-45 10/100 BASE-T for Ethernet communication Auto MDI/MDI-X DHCP server Provides isolated control network RS-232/422/485 Port 1 &...
  • Page 20: Mounting The Controller

    Included Accessories 1x 2-pin 3.5 mm mini-Phoenix PWR connector • 2x 6-pin 3.5 mm mini-Phoenix I/O connectors • • 2x 8-pin 3.5 mm mini-Phoenix Relay connectors • 2x 10-pin 3.5mm mini-Phoenix RS232/422/485 connectors 6x 5-pin 3.5mm mini-Phoenix RS232 connectors • 2x CC-NIRC, IR Emitters (FG10-000-11) •...
  • Page 21: Mounting The Mu-1000 And Mu-1300

    6. Apply power to the unit to complete the installation. Mounting the MU-1000 and MU-1300 Mounting options for the MU-1000 and MU-1300 are as follows: • Rack mounting with an AVB-VSTYLE-RMK-1U, V Style Module Rack Mounting Tray (FG1010-720) • Surface mounting with an AVB-VSTYLE-SURFACE-MNT, V Style Single Module Surface Mount (FG1010-722) DIN Rail mounting with a VSTYLE DIN Rail Clip (AMX-CAC0001) •...
  • Page 22: Icslan Leds

    Green Solid Booted Green Program running Blue Firmware transfer White Locate White ID Button Held (no action) Yellow ID Button Held (Config reset) ID Button Held (Factory reset) ICSLAN LEDs The ICSLAN LEDs light green when there is an active link on the corresponding ICSLAN port. The light toggles off when a data packet is sent or received.
  • Page 23: Wiring And Connections

    Wiring and Connections Overview This chapter provides details, specifications, wiring diagrams, and other important information for all port and connectors available on the MU-series controllers. Serial Ports The MU-series controllers each feature device control serial ports that support either RS-232 or RS-232, RS-422, and RS- 485 communication protocols.
  • Page 24: Relay Ports

    Relay Ports Relay Pinout Signal Function Signal Function Relay 1 Common Relay 1 NO Relay 2 Common Relay 2 NO Relay 3 Common Relay 3 NO Relay 4 Common Relay 4 NO Relay 5 Common Relay 5 NO Relay 6 Common Relay 6 NO Relay 7 Common Relay 7 NO...
  • Page 25: Icslan Ports

    ICSLAN Ports The MU-1000/2300/3300 controllers have two types of Ethernet ports: LAN and ICSLAN. The LAN port is used to connect the controller to an external network, and the ICSLAN ports are used to connect to other AMX equipment or third-party A/V equipment. The ICSLAN ports on all models provide Ethernet Communication to connected AMX Ethernet Equipment in a way that is isolated from the primary LAN connection.
  • Page 26: Id Pushbutton

    1. Strip 0.25 inch (6.35mm) of insulation off all wires. 2. Insert each wire into the appropriate opening on the connector (according to the wiring diagrams and connector types described in this section). 3. Tighten the screws to secure the wire in the connector. Do not tighten the screws excessively, as doing so may strip the threads and damage the connector.
  • Page 27: Led Patterns

    LED Patterns The MU-series features one visible-light tri-color status LED. Color Rate Status Yellow Solid Booting Green Solid Booted Green Program running Blue Firmware transfer White Locate White ID Button Held (no action) Yellow ID Button Held (Config reset) ID Button Held (Factory reset) ©...

Table of Contents