2. controls
Engine switch
To start and stop the engine
Switch position:
OFF: To stop the engine.
ON: To run the engine.
Recoil starter
To start the engine, pull the starter grip lightly resistance is felt, then pull briskly.
NOTICE
Do no allow the starter grip to snap back against the engine.
Return it gently to prevent damage to the starter.
Fuel valve lever
The fuel valve is located between the fuel tank and carburetor. When the valve lever is in the ON position, fuel is allowed to flow
from the fuel tank to the carburetor. Be sure to return the fuel valve lever to the OFF position after stopping the engine.
Choke rod
The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be opened and closed by operating the
choke lever manually. Pull the rod out toward CLOSED to enrich the mixture for cold starting.
Ground terminal
Before using the generator, carry out (or check each time) the connection of the earth terminal with a peg driven
into the ground. Before using the ground terminal, consult a qualified electrician, electrical inspector or local
agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator.
Oil alert system
The oil alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase.
Before the oil level in the crankcase can fall below a safe limit, the Oil Alert system will automatically stop the engine (the engine
switch will remain in the ON position). The Oil Alert system should not take place of checking the oil level before each use.
If engine stops or not restart, check the engine oil level (see page 13) before troubleshooting in other areas.
5