Honeywell SmartLine STT850 Quick Start Manual page 6

Temperature transmitter
Hide thumbs Also See for SmartLine STT850:
Table of Contents

Advertisement

A3. Hazardous Locations Certifications
MSG TABLE
TYPE OF
III/ AGENCY
PROTECTION
Explosion proof,
Certificate:
FM16US0157X:
Class I, Division 1,
Groups A, B, C, D;
Dust Ignition Proof:
Class II, III, Division 1,
Groups E, F, G; T6..T5
Class 1, Zone 1, AEx db
IIC T6..T5 Gb
Zone 21, AEx tb IIIC T
o
95
C Db
Intrinsically Safe,
Certificate:
FM16US0157X:
Class I, II, III, Division 1,
Groups A, B, C,
D, E, F, G; T4
A/ FM
Class I Zone 0 AEx ia IIC
Approvals
T4 Ga
TM
(USA)
FISCO Field Device
(Only for FF Option)
Class I Zone 0 AEx ia IIC
T4 Ga
Non-Incendive,
Certificate:
FM16US0157X:
Class I, Division 2,
Groups A, B, C, D; T4
Class I Zone 2 AEx nA
IIC T4 Gc
Class I Zone 2 AEx ic IIC
T4 Gc
Enclosure: Type 4X/
IP66/ IP67
Standards:
FM 3600:2018; ANSI/ ISA 60079-0: 2013 ; FM 3615:2018; ANSI/ ISA 60079-1 :
2015 ; FM 3616: 2011; ANSI/ ISA 60079-31: 2015 ; FM 3610:2010; ANSI/ ISA
60079-11: 2014; FM 3810 : 2018 ; FM 3611:2004; ANSI/ ISA 60079-15 : 2012;
FM 3810: 2005 ; NEMA 250: 2003; ANSI/ IEC 60529: 2004
COMM
Electrical
Ambient
OPTION
Parameters
Temperature
o
T95
C, T5: Ta=
o
o
4-20 mA/
-50
C to 85
C
o
DE/HART/
T6: Ta= -50
C
Note 1
o
FF/
to 65
C
PROFIBUS
o
o
-50
C to 70
C
4-20 mA/
FISCO:
DE/HART
o
o
Note 2
-50
C to 45
C
/FF/
PROFIBUS
4-20 mA/
Note 1
o
o
DE/HART
-50
C to 85
C
/FF/
"ic" Note 2
PROFIBUS
ALL
ALL
ALL
STT850/750 Quick Start Guide
Explosion proof, Certificate:
2689056:
Class I, Division 1, Groups A,
B, C, D;
Dust Ignition Proof:
Class II, Division 1, Groups E,
F, G; Class III, Division 1 ;T4
Class I Zone 1 AEx db IIC
T6..T5 Gb
o
Zone 21 AEx tb IIIC T 95
C Db
Ex db IIC T6..T5 Gb
o
Ex tb IIIC T 95
C Db
Intrinsically Safe, Certificate:
2689056:
Class I, II, III, Division 1,
Groups A, B, C, D, E, F, G; T4
Class I Zone 0 AEx ia IIC T4 Ga
Class I Zone 2Ex ic IIC T4 Gc
Ex ia IIC T4 Ga
Ex ic IIC T4 GcFISCO Field
Device (Only for FF Option)
Class I Zone 0 AEx ia IIC T4 Ga
Class I Zone 2Ex ic IIC T4 Gc
B/ CSA-
Ex ia IIC T4 Ga
Canada
Ex ic IIC T4 Gc
Non-Incendive, Certificate:
2689056:
Class I, Division 2, Groups A,
B, C, D; T4
Class I Zone 2 AEx nA IIC T4
Gc
Ex nA IIC T4 Gc
Enclosure: Type 4X/ IP66/
IP67
Standards:
CSA C22.2 No. 0-10; CSA 22.2 No. 25-1966 (reaffirmed 2009); CSA C22.2 No.
30-M1986 (reaffirmed 2012); CSA C22.2 No. 94-M91; CSA C22.2 No.61010-1:
2012; CSA-C22.2No.157-92 (reaffirmed 2016); C22.2 No. 213-2017; C22.2 No.
60529-2016; C22.2 No. CSA 60079-0:2015; C22.2 No. 60079-1: 2016; C22.2 No.
60079-11: 2014; C22.2 No. 60079-15: 2012; C22.2 No. 60079-31: 2015;
ANSI/ ISA12.12.01-2017; ANSI/ ISA 60079-0 (12.00.01): 2013; ANSI/ UL60079-1:
2015; ANSI/ ISA 60079-11(12.02.01) : 2012; ANSI/ ISA 60079-15(12.12.02) : 2012;
ANSI/ ISA 60079-31: 2015; FM Class 3615: Aug 2006; FM Class 3616: Dec 2011;
ANSI/ IEC 60529: Edition 2.1; ANSI/ UL 913: 2015; ANSI/UL 61010-1: 2016;
UL 50: Ed 11
o
T 95
C , T5: Ta=
o
o
-50
C to 85
C
4-20 mA/
o
Note 1
T6: Ta= -50
C to
DE/HART/FF
o
65
C
o
o
-50
C to 70
C
4-20 mA/
Note 2
FISCO:
DE/HART/FF
o
o
-50
C to 45
C
4-20 mA/
o
o
Note 1
-50
C to 85
C
DE/HART/FF
ALL
ALL
ALL
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartline stt750