Panasonic 4318 Technical Description
Panasonic 4318 Technical Description

Panasonic 4318 Technical Description

Combination heat detector
Hide thumbs Also See for 4318:

Advertisement

Quick Links

PANASONIC FIRE ALARM SOLUTIONS
TECHNICAL DESCRIPTION
4318
COMBINATION HEAT DETECTOR

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic 4318

  • Page 1 PANASONIC FIRE ALARM SOLUTIONS TECHNICAL DESCRIPTION 4318 COMBINATION HEAT DETECTOR...
  • Page 2 MEW01961 DATE OF ISSUE: 2016-01-11 REV: DATE OF REVISION: 2021-01-25 Panasonic Fire & Security Europe AB Jungmansgatan 12 SE-211 11 Malmö Sweden Tel: +46 (0)40 697 70 00 Internet: www.panasonic-fire-security.com TECHNICAL DESCRIPTION 4318 • DOCUMENT NUMBER: MEW01961 • REVISION: 2...
  • Page 3: Table Of Contents

    LATCHING ................................. 4 3.1.2 EXTERNAL LED ..............................4 ZONE LINE INPUT ........................5 MOUNTING ....................... 5 INSTALLATION AND WIRING .................. 6 TEST MODE ......................6 TECHNICAL DATA ....................7 APPROVALS ......................8 TECHNICAL DESCRIPTION 4318 • DOCUMENT NUMBER: MEW01961 • REVISION: 2...
  • Page 4: Introduction

    1. INTRODUCTION INTRODUCTION This document describes the combination heat detector, type number 4318. The document contains information about the product and instructions on how to mount and connect it. ABBREVIATIONS c.i.e Control and indicating equipment Light Emitting Diode TECHNICAL DESCRIPTION 4318 • DOCUMENT NUMBER: MEW01961 • REVISION: 2...
  • Page 5: General Description

    The detector's LED and a connected external LED will be lit until the detector is reset via the c.i.e. 3.1.2 EXTERNAL LED One External Indicator (LED) can be connected to the screw terminals E+ and E-: TECHNICAL DESCRIPTION 4318 • DOCUMENT NUMBER: MEW01961 • REVISION: 2...
  • Page 6: Zone Line Input

    The detector is plugged in a base. Place the detector in the base with the detector's "Mark" in the same position as the "Mark" on the base and turn the detector clockwise. TECHNICAL DESCRIPTION 4318 • DOCUMENT NUMBER: MEW01961 • REVISION: 2...
  • Page 7: Installation And Wiring

    For information about how to set a zone in test mode, see Planning Instructions or Operating Instructions. It is possible to use test equipment for testing, for example “SOLO” or “Testfire”. TECHNICAL DESCRIPTION 4318 • DOCUMENT NUMBER: MEW01961 • REVISION: 2...
  • Page 8: Technical Data

    Ingress protection rating IP 51 Size: Ø x H 102 x 39 mm Weight 54 g Available colours 4318 Grey (N8, Munsell colour code) 4318W White (10Y9/0.5, Munsell colour code) TECHNICAL DESCRIPTION 4318 • DOCUMENT NUMBER: MEW01961 • REVISION: 2...
  • Page 9: Approvals

    8. APPROVALS APPROVALS Applicable directive / Approval Applicable standards Notified body EN54-5 No. 0786-CPR-21198 EN54-5 VdS2344 No. G208048 VdS2503 EN61000-6-3 (Emission) Self declaration EN50130-4 (Immunity) RoHS EN50581 Self declaration TECHNICAL DESCRIPTION 4318 • DOCUMENT NUMBER: MEW01961 • REVISION: 2...

Table of Contents