Overview
Note
Note
Note
Note
Note
• Fan trays (three) (N9K-C9504-FAN) or (N9k-9504-FAN2) in slots FAN 1 to FAN 3 (numbered from
left to right on the chassis)
• Power supplies (up to two with the combined power mode, up to three with n+1 power redundancy mode,
or up to four with the n+n power redundancy mode) in slots PS 1 to PS 4 (numbered from left to right
on the chassis)
The fabric modules must be installed in specific slots as follows (installing
fabric modules in other slots can cause a module mismatch condition):
• For three modules, they must be in slots FM 2, FM 4, and FM 6
• For four modules, they must be in slots FM2, FM 3, FM 4, and FM 6
• For five modules, they can be in slots FM 1, FM 2, FM 3, FM 4, and
FM 6. Alternatively, they can be in Slots FM 2, FM 3, FM 4, FM 5,
and FM 6.
• For five FM-E or FM-E2 modules, they must be in Slots FM 2, FM 3,
FM 4, FM 5, and FM 6
• For six modules, they are in slots FM 1, FM 2, FM 3, FM 4, FM 5,
and FM 6
All of the fabric modules in a modular switch must be of the same type.
When using FM-G fabric modules, any empty slots should be filled with
FAN-PWR modules (N9K-C9504-FAN-PWR)
When using N9K-C9504-FM or N9K-C9504-FM-E fabric modules, any
empty slots should be filled with N9K-C9504-FM-CV.
For more information about Line card and fabric module compatibility, see
the
Cisco Nexus 9500 Platform Line Cards and Fabric Modules Data Sheet
• Cisco Nexus 9500 Series 3-kW AC power supply (N9K-PAC-3000W-B)
• Cisco Nexus 9500 Series 3-kW Universal AC/DC power supply (N9K-PUV-3000W-B)
• Cisco Nexus 9500 Series 3.15-kW Dual Input Universal AC/DC power supply
(N9K-PUV2-3000W-B)
• Cisco Nexus 9500 Series 3-kW (-48 V) DC power supply (N9K-PDC-3000W-B)
Cisco Nexus 9504 NX-OS Mode Switch Hardware Installation Guide
Overview
3