Package contents
Power supply unit
Power cord (varies by region)
Installation guide
All manuals and user guides at all-guides.com
Overview
The following table provides an overview of the power supply units (PSUs) for
managed switches and the models in which they are supported.
AC OK LED. All PSUs provide one AC OK
PSU Model
Used in Switch
LED. During normal operation, this LED
Model
lights green to indicate that the PSU is
receiving power.
APS150W
M4300-28G
DC OK LED. Model APS150W also provides
M4300-52G
one DC OK LED. During normal operation,
this LED lights green to indicate that the DC
APS250W
M4300-8X8F
outputs are within regulation limits.
M4300-12X12F
M4300-24X24F
APS299W
M4300-16X
APS550W
M4300-28G-POE+
M4300-52G-POE+
APS600W
M4300-96X
M4300-16X
APS750W
M4500-32C
M4500-48XF8C
APS1000W
M4300-28G-POE+
M4300-52G-POE+
M6100-3S
RPS4000v2
APS1200W
M4300-96X
Install an additional power supply unit
In models with more than one power supply bay, you can install an additional
PSU.
1. Pull out the cover plate from the power module bay in which you want to
insert the additional PSU.
2. Insert the additional PSU into the power module bay, and gently push the
PSU into the bay.
CAUTION:
When inserting the PSU, do not use unnecessary force. Doing so
can damage the connectors on the back of the PSU and on the midplane.
3. Connect the end of the power cord to the power receptacle on the PSU.
4. Plug the AC power cord into a power source such as a wall socket or power
strip.
When you apply power, the AC OK LED on the PSU lights. The LED on the
switch for the power supply bay also lights. If these LEDs do not light, make
sure that the power cord is plugged in and that the power source is good.
Replace a power supply unit
In models with more than one PSU, the PSUs are hot-pluggable.
1. If your switch functions with a single PSU only, disconnect the power cord
from the PSU and let the switch power down.
If your switch functions with more than one PSU, you do not need to power
down the switch and you can perform a hot swap.
2. Remove the PSU from the power module bay by moving the orange release
latch to the left and pulling the extraction handle.
3. Insert the replacement PSU into the power module bay, and gently push the
PSU into the bay until the latch locks.
CAUTION:
When inserting the PSU, do not use unnecessary force. Doing so
can damage the connectors on the back of the PSU and on the midplane.
4. Connect the end of the power cord to the power receptacle on the PSU.

Advertisement

loading

Summary of Contents for NETGEAR APS250W

  • Page 1 APS250W M4300-8X8F for Managed Switches outputs are within regulation limits. Replace a power supply unit M4300-12X12F APS150W, APS250W, APS299W, APS550W, APS600W, M4300-24X24F APS750W, APS1000W, and APS1200W APS299W M4300-16X In models with more than one PSU, the PSUs are hot-pluggable. APS550W M4300-28G-POE+ 1.
  • Page 2 (H x W x D) Thank you for purchasing this NETGEAR product. You can visit • APS250W. 1.5 x 2.9 x 7.3 in. (39 x 74 x 185 mm) switch for the power supply bay also lights. If these LEDs do not light, make https://www.netgear.com/support/...

This manual is also suitable for:

Aps150wAps299wAps550wAps600wAps750wAps1000w ... Show all