3. Pull the filter frame out of the housing pulling on the strap of the filter frame
Figure 3-4
4. Remove the filter pad.
5. Clean or replace the filter pad.
6. Insert the cleaned or new filter mat in the filter frame.
7. Insert the filter frame in the compartment again.
8. Close the cover and lock it by pushing the catch from right to left with a slotted screwdriver.
FAN597-1 / FAN597-2 fan unit for SCALANCE XR-500
Compact Operating Instructions, 02/2023, A5E03486841-03
Changing the filter pad of a SCALANCE XR552-12M SCALANCE XR528-6M is used
analogously.
Service and maintenance
3.2 Changing the filter pad
.