Siemens SIMATIC NET FAN597-1 Compact Operating Instructions

Industrial ethernet switches

Advertisement

Quick Links

SIMATIC NET
Industrial Ethernet switches
FAN597-1 / FAN597-2 fan unit for
SCALANCE XR-500
Compact Operating Instructions
02/2023
A5E03486841-03
Introduction
Description
Service and maintenance
Technical specifications
Dimension drawings
Approvals
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET FAN597-1

  • Page 1 Introduction Description Service and maintenance SIMATIC NET Technical specifications Industrial Ethernet switches FAN597-1 / FAN597-2 fan unit for Dimension drawings SCALANCE XR-500 Approvals Compact Operating Instructions 02/2023 A5E03486841-03...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction ............................5 Security information ......................5 Description............................. 7 Product characteristics ......................7 Unpacking and checking ...................... 7 Service and maintenance ........................9 Changing the fan unit ......................9 Changing the filter pad....................... 11 Technical specifications ........................15 Dimension drawings ..........................
  • Page 4 Table of contents FAN597-1 / FAN597-2 fan unit for SCALANCE XR-500 Compact Operating Instructions, 02/2023, A5E03486841-03...
  • Page 5: Introduction

    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure...
  • Page 6 Introduction 1.1 Security information Device defective If a fault develops, send the device to your SIEMENS representative for repair. Repairs on-site are not possible. Recycling and disposal The products are low in pollutants, can be recycled and meet the requirements of the WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment.
  • Page 7: Description

    Description Product characteristics Fan unit Type Properties Article number FAN597-1 For SCALANCE XR552-12M 6GK5 597-1AA00-8AA0 FAN597-2 For SCALANCE XR528-6M 6GK5 597-2AA00-8AA0 Note Replacing the filter pad To replace the filter pad, use the material Viledon P 15/150 G2 EN 779. The dimensions of the filter pad are as follows: •...
  • Page 8 2. Check all the parts for transport damage. If the consignment is incomplete or if there is damage to the exterior, contact your supplier or your local Siemens office. FAN597-1 / FAN597-2 fan unit for SCALANCE XR-500 Compact Operating Instructions, 02/2023, A5E03486841-03...
  • Page 9: Service And Maintenance

    Service and maintenance Changing the fan unit The following devices have a fan unit: • SCALANCE XR528-6M • SCALANCE XR552-12M NOTICE Operation of the SCALANCE XR-500 only with fan unit Use a SCALANCE X-500 only with a correctly fitted fan unit. Operating without the fan is not possible and would damage the device! You can, however, replace the fan unit during operation.
  • Page 10 3.1 Changing the fan unit Procedure Follow the steps below to replace the fan unit: 1. Unlock the door in the housing by pushing the catch to the right with a slotted ① screwdriver SIEMENS LOCKED OPEN LOCKED OPEN Figure 3-1 Opening the housing of a SCALANCE XR552-12M. SCALANCE XR528-6M is used analogously.
  • Page 11: Changing The Filter Pad

    Service and maintenance 3.2 Changing the filter pad ④ 4. Disconnect the fan unit and the filter frame Figure 3-2 Changing the fan of a SCALANCE XR552-12M SCALANCE XR528-6M is used analogously. 5. Push the new fan unit into the slot along the guide rails. 6.
  • Page 12 Procedure Follow the steps below to replace the filter pad: 1. Unlock the door in the housing by pushing the catch to the right with a slotted ① screwdriver SIEMENS LOCKED OPEN LOCKED OPEN Figure 3-3 Opening the housing of a SCALANCE XR552-12M. SCALANCE XR528-6M is used analogously.
  • Page 13 Service and maintenance 3.2 Changing the filter pad ③ 3. Pull the filter frame out of the housing pulling on the strap of the filter frame Figure 3-4 Changing the filter pad of a SCALANCE XR552-12M SCALANCE XR528-6M is used analogously. 4. Remove the filter pad. 5.
  • Page 14 Service and maintenance 3.2 Changing the filter pad FAN597-1 / FAN597-2 fan unit for SCALANCE XR-500 Compact Operating Instructions, 02/2023, A5E03486841-03...
  • Page 15: Technical Specifications

    Technical specifications Device variants The following technical specifications apply to the following device: • FAN597-1 fan unit • FAN597-2 fan unit Electrical connections Power supply 3-pin plug-in connector Fan control 3-pin plug-in connector Construction   FAN597-1 FAN597-2 Dimensions of the housing without 273 x 130 x 38 274 x 86 x 38 handle and module guide in mm...
  • Page 16 Technical specifications Maximum relative humidity in operation at 25 °C < 95 % no condensation Operating altitude above sea level depending on • 2000 m at max. 56 °C ambient temperature • 3000 m at max. 50 °C FAN597-1 / FAN597-2 fan unit for SCALANCE XR-500 Compact Operating Instructions, 02/2023, A5E03486841-03...
  • Page 17: Dimension Drawings

    Dimension drawings FAN597-1 View from the front, top, and side Dimensions are specified in mm. FAN597-1 / FAN597-2 fan unit for SCALANCE XR-500 Compact Operating Instructions, 02/2023, A5E03486841-03...
  • Page 18: Fan597-2

    Dimension drawings 5.2 FAN597-2 FAN597-2 View from the front, top, and side Dimensions are specified in mm. FAN597-1 / FAN597-2 fan unit for SCALANCE XR-500 Compact Operating Instructions, 02/2023, A5E03486841-03...
  • Page 19: Approvals

    Approvals The SIMATIC NET products described in these Operating Instructions have the approvals listed below. Note Issued approvals on the type plate of the device The specified approvals apply only when the corresponding mark is printed on the product. You can check which of the following approvals have been granted for your product by the markings on the type plate.
  • Page 20 EC L174, 01/07/2011, pages 88-110 You will find the EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15248/ cert).
  • Page 21: Index

    Index Door in housing, 10, 12 Fan unit, 7, 9 Filter frame, 10, 13 Filter pad, 10, 12 FAN597-1 / FAN597-2 fan unit for SCALANCE XR-500 Compact Operating Instructions, 02/2023, A5E03486841-03...