Troubleshooting - Husqvarna DE 110i H Operator's Manual

Hide thumbs Also See for DE 110i H:
Table of Contents

Advertisement

Available languages

Available languages

2. Attach the dust cap (A) and pull out the HEPA filter.
Put it into a clean plastic bag (C).
A
B
Troubleshooting schedule
Problem
The motor stops immediately af-
ter start or does not start.
22
C

Troubleshooting

Cause
There is no power.
There is a fault with the battery.
The green LED flashes on the battery.
The HEPA filter is damaged or not installed.
There is a short circuit in the product.
Too high voltage in power supply.
Too high ambient temperature.
Fan is broken or disconnected.
3. Discard the plastic bag correctly. Refer to local
regulations.
4. Install a new HEPA filter. Make sure that the HEPA
filter is pushed to the end position.
5. Install the HEPA filter cover and tighten the 6
screws.
Solution
Connect the battery to the prod-
uct.
Do a check of the battery or re-
place the battery if necessary.
Let an approved service agent
repair the product.
Low battery voltage. Charge the
battery.
Replace or install the HEPA fil-
ter.
Let an approved service agent
repair the product.
Make sure that correct power
supply is used.
Make sure that the ambient
temperature is in specified
range when you use the prod-
uct.
Let an approved service agent
repair the product.
1618 - 006 - 01.06.2023

Advertisement

Table of Contents
loading

This manual is also suitable for:

De 120 h pace