5.1.1. Installing The Cisco FM4200 Mobi ..........29 Environmental Rating And Unit Roles ..........29 Installation Hardware ............... 29 5.1.2. Cisco FM4200 Mobi Status And Link LEDs ........29 Unit And Link Quality Status ............29 Boot Sequence ................30 5.1.3.
Page 4
Device Firmware Reboot ..............32 Resetting The Unit To Factory Settings ..........32 5.1.5. Suitability For Outdoor Installation ..........33 5.2. Connecting The Fluidmesh Cisco FM4200 Mobi To A Network And Antennas ....................34 5.2.1. Terminal Assignments For Power And Data Connectors ....34 M12 A-Coded .................
Cisco Ultra-Reliable Wireless Backhaul FM4200 Mobi 1.1. Water ingress hazard CAUTION In all circumstances where the Cisco FM4200 Mobi will be installed in an outdoor location, it is compulsory to mount the Cisco FM4200 Mobi inside an FM-SHIELD auxiliary mounting kit.
The Cisco FM4200 Mobi radio transceiver Introduction The Cisco FM4200 Mobi is designed to operate in the sub-6 GHz range as a static-mount wireless data link. In non-technical terms, this means it is designed to function as an intermediate radio link between a core wired data network and a sub-network.
3.2. Fluidmesh architecture 3.2.1. Overview Wireless network architectures Depending on the network design and the type of components used, the Cisco FM4200 Mobi can be used to create wireless network architectures, including: • Point-to-point (P2P) links. • Point-to-multipoint (PTMP) sectors.
In a reliable mesh network with an acceptable amount of redundancy, every stream of data packets may reach the base station through any of a variety of paths. The Cisco FM4200 Mobi is designed to act as an 'intelligent router' that is able to forward packets coming from other Fluidmesh components in real time, based on an optimal, software- determined path.
3.3. Fluidmesh Network Addressing 3.3.1. Bridge IP addressing If needed, the Cisco FM4200 Mobi can be operated in Bridge mode. This creates a single point-to-point connection between two network segments. A simplified example of a Bridge mode connection is shown in...
Fluidmesh radio transceivers Fluidmesh data link layer (layer 2) addressing allows you to configure each Cisco FM4200 Mobi transceiver unit, and each IP device connected to the unit, according to the IP address class used in the private LAN to which the Mesh End unit is connected.
Connecting and configuring an Ethernet edge device Ethernet edge devices such as IP cameras and Wi-Fi access points can be connected to the Ethernet ports of the Cisco FM4200 Mobi. Such edge devices must be configured using the IP subnet scheme defined for the broadcast domain.
Installation hardware Metal clamps are supplied as part of the installation package, to allow mounting of the unit on utility poles. Refer to the Cisco FM4200 Mobi installation instructions for details. 5.1.2. Cisco FM4200 Mobi Status and link LEDs...
5.1.3. Supplying power to the Cisco FM4200 Mobi CAUTION When connecting the Cisco FM4200 Mobi to a power supply, be sure to follow the instructions in this section at all times. Failure to follow these instructions may result in irreparable damage to the unit and/or other connected hardware, and will also invalidate the product warranty.
Cisco Ultra-Reliable Wireless Backhaul FM4200 Mobi The Cisco FM4200 Mobi can be provided with power using the following methods: • A standard IEEE 802.3af Power-over-Ethernet (PoE) connection (for example, from a compatible network switch). • A compatible 48 Vdc passive PoE injector conforming to either IEEE 802.3af...
Backhaul FM4200 Mobi 5.1.4. Rebooting the firmware and resetting the unit to factory defaults The Cisco FM4200 Mobi hardware can be rebooted and reset to factory default condition using the procedures in this section. IMPORTANT The following procedure shows how to do a 'hard' (device firmware) reboot.
• The administrator user name and password will both be reset to admin. 5.1.5. Suitability for outdoor installation The Cisco FM4200 Mobi was specifically designed for installation in harsh outdoor environments. Under operating conditions, the unit is completely sealed, and is capable of high-performance operation in outdoor environments, and under severe conditions such as water spray, salt, and extreme fluctuations in cold and heat.
Cisco Ultra-Reliable Wireless Backhaul FM4200 Mobi 5.2. Connecting the Fluidmesh Cisco FM4200 Mobi to a network and antennas 5.2.1. Terminal assignments for power and data connectors IMPORTANT Always use outdoor-rated, RF-shielded Ethernet cables when connecting the Power and LAN ports of a Fluidmesh hardware device to external hardware.
• Terminal 8 of M12A (Green wire) to terminal 4 of M12X. M12 X-coded M12 X-coded connectors are used on all Fluidmesh Cisco 4200-series and Cisco 4500-series units manufactured after September 2016. When splicing a male M12 X-coded connector to one end of an Ethernet...
“Connecting LAN cables to the unit” (page 38). When the Cisco FM4200 Mobi is mounted in its final location, connect the unit to a 48V DC IN power supply by doing the following steps: Only use a power cable that terminates in an M12A connector to connect the power source to the unit.
48V DC IN power supply to the unit as shown in “Connecting a DC IN power source to the unit” (page 37). When the Cisco FM4200 Mobi is mounted in its final location, connect the unit to LAN connection(s) and/or a PoE power supply by doing the following steps: Only use a shielded CAT5/6 cable that terminates in an M12X connector to connect any LAN cable to the unit.
Following the instructions in this section will also ensure that the FM4200 Mobi is well prepared for any ingress-protection testing. Radio antennas are connected to the Cisco FM4200 Mobi using quick- disconnect sub-miniature version A (QMA) connectors. WARNING Before activating the unit, make sure that all RF feeds are securely connected to an appropriate antenna.
CONFIGURATOR INTERFACE Fluidmesh radio devices that are capable of operating as part of a mesh network, including the Cisco FM4200 Mobi, are shipped from the factory in Mesh Point mode. All Fluidmesh radio transceiver devices are shipped with IP address 192.168.0.10, and Netmask 255.255.255.0.
7.1. Software and hardware prerequisites To access the Configurator graphical user interface (GUI) and use the Configurator to program the Cisco FM4200 Mobi, you need the following: • A desktop, laptop or tablet computer equipped with: • Any current web browser. For a list of compatible web browsers, refer to the Supported web browsers table in “Using the Fluidmesh Partner Portal”...
(Internet access) 7.2.1. Initial configuration with the unit in Provisioning Mode The Cisco FM4200 Mobi cannot be operated without entering some basic configuration settings. These settings allow the unit to connect to a local network and communicate with the network hardware.
Page 52
• If you want to change the connection settings, but keep the current configuration, change the settings as shown in “General settings” (page 59). If the Cisco FM4200 Mobi is in Provisioning Mode: • The RACER™ dialog will be shown (Figure 14 (page 52)).
Page 53
NOTE DHCP is disabled when the unit leaves Provisioning Mode. Make sure that the Cisco FM4200 Mobi is connected to a local network that supports DHCP. If the unit connects successfully to the internet and to the Partners Portal, the RACER™ Cloud connection info Status will be...
Changing the Prodigy version IMPORTANT Prodigy version selection is only available if the Cisco FM4200 Mobi is set to Mesh Point mode or Mesh End mode. If the unit is set to Bridge mode, the Prodigy Version selector will not be available.
7.4.2. Wireless settings Modifying the wireless settings IMPORTANT If the Cisco FM4200 Mobi was purchased in the USA or Canada, the Country selection is set to the country of purchase, and the Country: drop-down will be disabled. The WIRELESS RADIO window contains controls to change the following settings: •...
IP addresses. If connectivity is lost between the unit and any of the saved IP addresses, an option can also be set to automatically reboot the Cisco FM4200 Mobi. As well as being a fail-safe mechanism to monitor network...
FM-QUADRO for mesh network-capable devices IMPORTANT The FM-QUADRO tool is only available if the Cisco FM4200 Mobi is set to Mesh End mode or Bridge mode. If the unit is set to Mesh Point mode, the -FMQuadro™ menu option will not be available.
7.6.4. Pass lists and Block lists IMPORTANT The Pass list or Block list feature is only available if the Cisco FM4200 Mobi is set to Mesh Point mode or Mesh End mode mode. If the unit is set to Bridge mode, the –pass list / block list menu option will not be available.
Save the SNMP settings by clicking the Save button. Alternatively, clear the settings by clicking the Reset button. 7.6.7. Wireless access point configuration All FM1200 Volo, Cisco 3200-series and Cisco 4200-series radio transceivers equipped with firmware version 6.5 and above have a built-in wireless access point (AP).
Page 108
Cisco Ultra-Reliable Wireless Backhaul FM4200 Mobi To enable the wireless AP feature on the Cisco FM4200 Mobi, do the steps that follow: 1. Make sure the FM-AP software plug-in is installed on the radio unit. For instructions on how to install the FM-AP plug-in, refer to “Plug-in management procedures”...
• Wi-Fi capability. • A current version of Mozilla Firefox or Google Chrome. To connect wirelessly to the Cisco FM4200 Mobi for configuration and maintenance, do the following steps: 1. On your computer or other wireless interface device, use the Wi- Fi connection dialog to connect to the radio unit using the radio unit's WLAN SSID and WLAN passphrase.
Page 112
Backhaul FM4200 Mobi IMPORTANT The RADIUS feature is only available if the Cisco FM4200 Mobi is set to Mesh Point mode or Mesh End mode. If the unit is set to Bridge mode, the -radius menu option will not be available.
Reset button. 7.6.10. L2TP configuration IMPORTANT The L2TP configuration option is only available if the Cisco FM4200 Mobi is set to Mesh Point mode or Mesh End mode. If the unit is set to Bridge mode, the -l2tp configuration menu option will not be available.
L2TP configuration, refer to the Fluidmesh Networks L2TPv3 Configuration Manual. 7.6.11. VLAN settings VLAN configuration The VLAN SETTINGS window contains controls to connect the Cisco FM4200 Mobi to one or more virtual local area networks (VLANs) that are part of the local wireless network. IMPORTANT The VLAN feature must be enabled using a software plug-in (Fluidmesh part number FM-VLAN).
7.6.12. Fluidity settings IMPORTANT The Fluidity tool is only available if the Cisco FM4200 Mobi is set to Mesh Point mode or Mesh End mode. If the unit is set to Bridge mode, the -Fluidity™ menu option will not be available.
The MISC SETTINGS window contains controls to change the following settings: • The device name, as used to identify the Cisco FM4200 Mobi within the FMQuadro network map and to other Fluidmesh utilities. • The operation of the physical Reset button on the unit.
Reset button. 7.7.3. Overwriting and upgrading the unit firmware The FIRMWARE UPGRADE window contains controls to overwrite the device firmware of the Cisco FM4200 Mobi, or upgrade the firmware to the latest available version. CAUTION Overwriting the firmware of any electronic device must be done with great care, and always contains an element of risk.
• The configuration will be applied, and the unit will reboot. 7.7.7. Resetting the unit to factory defaults The reset factory default window contains controls that allow you to restore the Cisco FM4200 Mobi to its default factory settings (in other words, to do a 'hard reset'). IMPORTANT...
Cisco Ultra-Reliable Wireless Backhaul FM4200 Mobi Rebooting the unit The reboot window contains controls that allow you to reboot the Cisco FM4200 Mobi (in other words, to re-start the unit's operating system). To reboot the unit, do the following steps: Click the -reboot link under MANAGEMENT SETTINGS in the left-hand settings menu.
Backhaul FM4200 Mobi 7.7.9. Viewing the end-user license agreement The License Agreement window contains the Fluidmesh end-user license agreement for the Cisco FM4200 Mobi, its firmware and control software. To view the terms and conditions of the license agreement, click the License Agreement link under MANAGEMENT SETTINGS in the left- hand settings menu.
Backhaul FM4200 Mobi 8. SOFTWARE PLUG-INS 8.1. Available plug-ins Like other Fluidmesh radio transceivers, the Cisco FM4200 Mobi is able to take advantage of plug-in software upgrades that add features and enhance the performance of the unit. The following table lists all available software plug-ins for all Fluidmesh hardware devices, their specific functions, and their plug-in part numbers.
Page 148
Not available TITAN Available Not available Available Not available UNII2 Not available Not available Available Not available Table 8. Device plug-in compatibility (FM Cisco 3200-series to FM 4800) Plugin FM Cisco FM 4800 FM3200 FM3500 FM4200 FM4500 Base Endo Fiber...
Page 166
EC Declaration of Conformity Fluidmesh Networks, Inc. declares under its sole responsibility that the Cisco FM4200 Mobi is compliant with the following directives, and has been designed and manufactured to the following specifications: EN 61000-6-1; EN 61000-6-2; EN 61000-6-3; EN 61000-6-4;...
Page 169
Cisco Ultra-Reliable Wireless Backhaul FM4200 Mobi information. In no event shall Cisco Systems be held liable for any incidental, consequential or special damages, whether based on tort, contract or otherwise, arising out of or in connection with this manual, the software or other information contained herein, or use thereof.
Agreement, will be prosecuted to the maximum extent allowable under law. 14.2. Notice This is an agreement between you and Fluidmesh, a division of Cisco (hereafter known as 'Fluidmesh'). You must read and agree to the terms of this firmware license agreement (hereafter known as the 'agreement') before any Fluidmesh firmware can be downloaded, installed or used.
Cisco Ultra-Reliable Wireless Backhaul FM4200 Mobi (f) remove any Cisco or Fluidmesh copyright notice, or Cisco or Fluidmesh branding from the Fluidmesh Firmware or modify any user interface of the Fluidmesh Firmware or Fluidmesh Device. Fluidmesh Devices must be properly installed and they are sold for installation by a professional installer only.