Function Of Switches And Connectors (Outdoor Unit) - Mitsubishi Electric PUH-P200MYA Technical & Service Manual

Air-cooled split-type packaged air conditioners
Hide thumbs Also See for PUH-P200MYA:
Table of Contents

Advertisement

[3] Function of switches and connectors (outdoor unit)

(1) Function of switches
1) Function of switches
(Normal mode)
Kind of
Switch
Pole
switch
1
2
SW1
3
CN33
When
4
open
(Normal)
5
DIP SW
6
1
2
SW2
3
4
5
6
Tact SW
SW3
1
DIP SW
SW4
2
1
2
DIP SW
SW5
3
4
2) Switch functions at set mode change
Kind of
Switch
Pole
switch
1
SW1
2
When
3
DIP SW
CN33
4
shorted
(mode
5
switching)
6
*1 Trial run performs trail run processing by input change while stopped. (For details, see the trail run section)
*2 Mode input is entered by SW3 OFF→ON change (___ ↑ ). Press and hold down SW3 for about 2 seconds. The set
mode can be registered according to the outdoor unit setting information on page 31.
Note: After changing the mode by CN33 shorting (mode switching), return to the normal mode by opening CN33.
3) Connector function assignment
Type
Connector
CN31
Connector
CN32
CN33
DIP switch mode switching
Function
None
Abnormality history clear
Refrigerant system
address setting
Self diagnosis
Mode input register
Trial run
Trial run mode switching
Inlet temp. re-reading
3-phase power source
detection
Cooling only switching
Model setting
Function
None
Night mode
Defrosting end switching
Defrosting prohibit time
switching
None
Function
Emergency operation
Function test
Normal mode
SW3 = Unrelated
Operation by switch operation
ON
Clear
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
ON
OFF
OFF
OFF
0
1
2
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
ON
OFF
OFF
OFF
5
6
7
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
ON
OFF
OFF
OFF
10
11
12
→ Shows that Nos. 3, 4, 5 , and 6 of
1 2 3 4 5 6
ON
OFF
SW1 are ON.
15
See pages 29 to 34.
Register
Operate
Heat
Do
Do not
Cooling only
PUH-P250MYA
Set input mode
CN33 = short SW3 = ON*
Operation by switch operation
ON
Night mode
12 °C continuous 2 min-
8 °C continuous 2 min-
utes
utes
Fixed
Operation by open/short
short
Start
Function mode
Mode switching
–28–
Switch effec-
tive timing
OFF
Running or
Normal
stopped
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
OFF
OFF
3
4
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
OFF
OFF
When power
8
9
1 2 3 4 5 6
1 2 3 4 5 6
turned on
ON
ON
OFF
OFF
13
14
Running or
stopped
Normal
stopped
Stop
stopped*
Cool
stopped
Do not
When power
Do
turned on
Heat pump
When power
turned on
PUH-P200MYA
2
Switch effec-
tive timing
OFF
stopped
Normal mode
stopped
Training
stopped
Switch effec-
tive timing
open
Normal
At initialization
At initialization
Normal
Normal
stopped
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Puh-p250mya

Table of Contents