Electrical Wiring Diagram; Outdoor Unit - Mitsubishi Electric PUH-P200MYA Technical & Service Manual

Air-cooled split-type packaged air conditioners
Hide thumbs Also See for PUH-P200MYA:
Table of Contents

Advertisement

4 ELECTRICAL WIRING DIAGRAM

[1] Outdoor Unit

• Model PUH-P200MYA/P250MYA
MC
(*1)
MF
1
3
1
3
C12
(3P)
(3P)
52C
1 3
5
51C
CNFAN
1
(5P)
CNFC2
F.C.
(6P)
BOARD
52C
6
CNPO
(5P)
CNOUT1
3
5
1
1
3
(5P)
CNOUT2
1
(3P)
F10
3
F20
5
F30
7
CNIN
N.F.BOARD
(7P)
GREEN/YELLOW
F1
F2
TB1
TB3
L1
L2 L3 N PE
S1 S2 S3
PE
CIRCUIT BREAKER
(FIELD SUPPLY)
PUH-P200MYA-EU : 50A
PUH-P250MYA-EU : 60A
POWER SUPPLY
3N~PE
380/400/415V
50HZ
Symbol
Name
F1, F2
FUSE (15A 250VAC CLASS T)
~
F01
F04
FUSE (6.3A 250VAC CLASS F)
~
F10
F30
FUSE (6.3A 250VAC CLASS F)
51C
OVER CURRENT RELAY (COMPRESSOR)
52C
MAGNETIC CONTACTOR (COMPRESSOR)
63L
PRESSURE SWITCH (LOW PRESSURE)
63H1
PRESSURE SWITCH (HIGH PRESSURE)
63H2
PRESSURE SWITCH (FOR CONTROL)
MC
COMPRESSOR MOTOR
MF
FAN MOTOR (OUTDOOR)
TR
TRANSFORMER
X1
AUXILIARY RELAY (FOR 16, 20HP)
LED 1
LED (FOR SERVICE)
~
X01
X05
AUXILIARY RELAY (MAIN BOARD)
CN2,CN20~28
CN3,34,30,3N,3S
CN4,40,51~53,81 CONNECTOR MAIN BOARD
CNFC1, FG, S3
CNMT,VMNT
63H1
63L
CH
SV1
21S4
CNVMNT
51C
CN23
(3P)
1
(3P)
3
CN22
(3P)
1
3
CN21
(3P)
1
3
52C
X04
CN26
(5P)
1
3
5
CN25
(3P)
1
3
CN53
(3P)
1
3
CN52
(6P)
1
3
5
6
CNFC1
(6P)
1
6
CN20
(7P)
L1
7
F01
N
F04
L2
F02
L3
1
F03
X1
PE
3
1
TB8
OUT OUT
IN
IN
INDOOR UNIT
TO INDOOR UNIT
CONNECTING WIRES (*2)
TB4
(POLER)
S1
S2
S3
TH1
TH2
TH3
LEV
2 1
2 1
2 1
CNMNT
CN40
CN2
CN3
CN4
(5P)
(6P)
(2P)
(2P)
(2P)
CN3D
(3P)
(*3)
O
CN3S
(3P)
OFF
4
1
SW5
CN3N
O
O
(3P)
OFF
OFF
1
2
1
6
CN24
SW3
SW4
SW1
(3P)
X03
LED1
O
CN27
OFF
(3P)
1
6
SW2
X01
CN81
X02
(3P)
X05
CN51
(5P)
Transmission
Circuit
DC power
supply
CN34
CN28
CNS3
CNFG
(3P)
(3P)
(3P)
(3P)
3
1
3
3
1
TR
OUTDOOR UNIT CONTROL BOX
Symbol
Name
~
SW1
SW5
SWITCH (MAIN BORD)
21S4
4-WAY VALVE
SV1
SOLENOID VALVE
CH
CRANK CASE HEATER (COMPRESSOR)
LEV
ELECTRINIC EXPANSION VALVE
TH1
TH2
THERMISTOR
TH3
TB1
POWER SOURCE TERMINAL BLOCK
TB3, 4
OUTDOOR/INDOOR CONNECTION TERMINAL BLOCK
TB8
TERMINAL BLOCK (FOR 16, 20HP)
C11, C12
CONNECTOR (FAN MOTOR)
C14
CONNECTOR (63H2)
CAFAN, CNFC2
CONNECTOR (F. C. BOARD)
CNPO
CNOUT1, 2
CONNECTOR (N, F. BOARD)
CNIN
–11–
X1
3
1
63H2
3
2
1
1
C14
(2P)
Note :
1. Be sure to apply earth work to the unit.
(Use the earth terminal of TB1.)
2. The dotted lines show field wiring.
3. Color of earth wire is yellow and green
twisting.
4. This motor (*1) includes auto reset type
internal thermostat.
5. Indoor and outdoor connecting wires
(*2) are made with polarities, make
sure matching wiring and terminal.
6. SW5 (*3) is shown PUH-P250MYA set-
ting.
In case of PUH-P200MYA setting is
shown as below.
1
(*3)
ON
OFF
1
SW5
Caution :
1. To protect compressor from abnormal cur-
rent, over current relays is installed. There-
fore, do not change factory set value of over
current relays.
LIQUID TEMP.
DISCHARGE TEMP.
COND./EVA. TEMP.
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Puh-p250mya

Table of Contents