OPERATION

Do not disassemble check valve, tank drain valves or safety relief
valve with air in tank — bleed tank.
Always wear eye protection with side shields. Failure to do so could
result in objects being thrown into your eyes resulting in possible
serious injury.
Do not attach any tools to the open end of the hose until start-up
has been completed.
CAUTION
Do not use in an environment that is dusty or otherwise
contaminated. Using the air compressor in this type of environment
may cause damage to the unit.
TRANSPORTING THE AIR COMPRESSOR
See figure 6a.
The air compressor should be moved as instructed. This will help
you avoid damaging the wheel or the air compressor by rolling it over
items in its path.
Ensure the air compressor is unplugged and the power cord is
secured from free movement.
To move the air compressor:
1. Grasp the front handle firmly with two hands.
2. Lift the air compressor toward you. Make sure the compressor is
balanced on the wheels.
3. Push the unit along to the desired location.
4. Lower the air compressor until it sits securely on a flat surface.
To transport the air compressor up or down stairs:
See figure 6b.
1. Grasp the front handle and rear handle firmly. Lift the unit into a
safe and comfortable carrying position.
NOTE: Use good lifting techniques and get help if needed.
2. With proper footing and balance, carry the unit one step at a time.
3. Use care in transporting the unit down or up stairs to avoid
damage to the stairs, damage to unit and personal injury. Pay
extra attention to the drain valve which is under the tank during
transportation, to avoid any damage.
4. Lower the air compressor until it sits securely on a flat surface.
ATTACHING/DISCONNECTING AIR HOSE
See figure 7.
NOTE:
For
operation
using
(102 psi) delivery hoses should be fitted with a safety cord, e.g., wire
rope.
1. Make sure the air compressor is off and unplugged.
2. Rotate pressure regulator knob fully counterclockwise.
3. Rotate pressure regulator locking ring fully counterclockwise.
DANGER
WARNING
WARNING
pressures
above
7
4. Confirm that the outlet pressure is at zero (0) bar.
5. Attach hose with quick connect air fitting to 6.35 mm (1/4 in.)
quick connect coupler (regulated pressure) on air compressor.
Make sure to push the hose adapter end fully into the coupler
until the sleeve springs forward to lock it in place.
To disconnect an air hose or an air tool:
1. Rotate pressure regulator knob fully counterclockwise.
2. Confirm that the outlet pressure is at zero (0) bar.
3. When disconnecting a hose from 6.35 mm (1/4 in.) quick coupler,
always firmly hold release end of hose.
4. Pull back on the release sleeve on the 6.35 mm
(1/4 in.) quick coupler.
5. With a firm grip, pull out the quick connect air fitting that is
attached to the quick coupler.
TURNING THE AIR COMPRESSOR ON/OFF
See figure 9.
1.
With the air compressor plugged in, pull the power switch to the
ON position to power the compressor on.
2. To turn the air compressor off, push the power switch to the OFF
position.
NOTE: When the compressor is in the ON position, the air
compressor will automatically turn on when the designated tank
air pressure drops below the preset pressure limit. It will also shut
off again when the desired pressure is reached.
Never exceed the air tool's pressure rating as recommended by
the manufacturer. When using this air compressor as an inflation
device, always follow the maximum inflation guidelines stated by
the manufacturer of the item being inflated.
Always ensure the switch is in the OFF (O) position and the
regulator pressure gauge reads zero before changing air tools or
disconnecting the hose from the air outlet. Failure to do so could
result in possible serious personal injury.

USING THE AIR COMPRESSOR

See figure 8 - 9.
1. Ensure power switch is in the OFF (O) position and air compressor
is unplugged.
2. If not already installed, attach hose to compressor as previously
instructed.
3. Attach 6.35 mm (1/4 in.) quick connect air fitting to accessory or
tool you intend to use.
4. Insert the other end of the quick connect air fitting to the quick
coupler (regulated pressure) on the open end of hose.
5. Connect the power cord to the power supply.
6. Turn the switch ON ( l ).
7. Rotate pressure regulator knob to desired line pressure. Turning
the knob clockwise increases air pressure at the outlet; turning
counterclockwise reduces air pressure at the outlet.
bar,
8. Rotate pressure regulator locking ring fully counterclockwise to
lock the air pressure.
9. Following all safety precautions in this manual and the
manufacturer's instructions in the air tool manual, you may now
proceed to use your air-powered tool.