to instruct others who may use this product. If you loan someone
this product, loan them these instructions also.
■ The machine shall be connected to a circuit protection device
(fuse or circuit breaker).
■ Operate the machine from the front of the control panel.
■ When the machine is in operation, many parts of machine may
cause a high temperature. Use necessary personal protection
equipment such as gloves to avoid injuries resulting from a high
temperature.
■ When using the product with an extension cord, use a 3*1.0 mm
heavy duty extension cord only.
■ This machine is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised
to ensure that they do not play with the machine.

RESIDUAL RISKS

Even when the product is used as prescribed, it is still impossible
to completely eliminate certain residual risk factors. The following
hazards may arise and the operator should pay special attention to
avoid the following:
■ Use the product only for its intended use. Do not alter or modify
the product from the original design or function.
■ Always be aware that misuse and improper handling of the
product can cause injury to yourself and others.
■ Never leave an air compressor unattended with the hose attached
to a tool.
■ Do not continue to use an air compressor or hose which leaks air
or does not function properly.
■ Risk of bursting
– Do not adjust regulator to result in output pressure greater
than marked maximum pressure of attachment.
■ Heat and high temperature are generated while motor and
cylinder are running. Touching exposed metal can result in
serious burns.
– Always keep the air compressor away from the working zones.
■ Injury casued by noise
– Wear ear protection.
■ The gas from air compressor can propel dirt, chips, loose particles
and small objects at high speed. This may result in objects being
thrown into eyes or other possible serious injury.
– Always wear proper personal protective equipment when
operating different tools.
WARNING! Do not remove the NITTO couplers on the product.
Altering the NITTO style couplers which are fixed and sealed on the
product will void your warranty. If you would like to use alternative
style fittings, please use an adaptor for the application.
SPECIFIED CONDITIONS OF USE
This compressor is designed to supply pressurised air only. It must
not be used to compress any other gas. It is designed to operate air
powered tools. The compressor should be operated indoors only.
UNPACKING
Carefully remove the product and any accessories from the box.
WARNING! Inspect the product carefully to make sure no
breakage or damage occurred during shipping. Do not discard the
packing material until you have carefully inspected and satisfactorily
operated the product.
WARNING! If any parts are damaged or missing do not operate
the product until the parts are replaced. Use of the product with
damaged or missing parts could result in serious personal injury.
2
WARNING! Do not attempt to modify the product or create
accessories not recommended for use with the product. Any such
alteration or modification is misuse and could result in a hazardous
condition leading to possible serious personal injury.
Packing list
– Air compressor
– Operator's manual

OPERATION

DANGER! Do not disassemble the Nitto couplers, check valve,
tank drain valves or safety relief valve with air in tank — bleed tank.
WARNING! Always wear eye protection with side shields. Failure
to do so could result in objects being thrown into your eyes resulting
in possible serious injury.
WARNING! Do not attach any tools to the open end of the hose
until start-up has been completed.
WARNING! The solenoid valve releases pressure when the air
compressor reaches the maximum pressure. The LED of the solenoid
valve should light up normally when it is powered on. Keep the
solenoid valve clean, and do not block the vent with debris. User is not
allowed to remove or modify the solenoid nut.
CAUTION! Do not use in an environment that is dusty or
otherwise contaminated. Using the air compressor in this type of
environment may cause damage to the unit.
ATTACHING/DISCONNECTING AIR HOSE
See figure 1.
NOTE:
For
operation
(87 psi) delivery hoses should be fitted with a safety cord, e.g., wire
rope.
1. Make sure the air compressor is off and unplugged.
2. Rotate pressure regulator knob fully counterclockwise.
3. Confirm that the outlet pressure is at zero (0) bar.
4. Attach hose with quick connect air fitting to 6.35 mm (1/4 in.)
quick connect coupler (regulated pressure) on air compressor.
Make sure to push the hose adapter end fully into the coupler
until the sleeve springs forward to lock it in place.
To disconnect an air hose or an air tool:
1. Rotate pressure regulator knob fully counterclockwise.
2. Confirm that the outlet pressure is at zero (0) bar.
3. When disconnecting a hose from quick coupler, always firmly hold
the release end of hose.
4. Pull back on the release sleeve on the quick coupler.
5. With a firm grip, pull out the quick connect air fitting that is
attached to the quick coupler.
7
using
pressures
above
6
bar,
7