Group
Parameter
Discharge
Exponent
Reynolds
Coefficient_
r1
Coefficient of
discharge
Reynolds
Cd
Coefficient_
r2
Upper limit
Reynolds
Num_
RnMax
Lower limit
Reynolds
Num_
RnMin
Page 174
Values
0.75
0.5
SMV800 Series HART/DE Option User's Manual
Description
Applicable when Algorithm
Options = SMV3000
Equation Model = Dynamic.
Based on the selected Primary
element, this is auto calculated.
Coefficient of Discharge in the
Flow equation is calculated
using Discharge Exponent,
Reynolds Coefficinet_r1 and
Reynolds Coefficinet_r2.
Based on the selected Primary
element, this is auto calculated.
Applicable when Algorithm
Options = SMV3000 Equation
Model = Dynamic
Based on the selected Primary
element, this is auto calculated.
Applicable when Algorithm
Options = SMV3000 Equation
Model = Dynamic
Upper limit for Reynolds
number. Applicable when
Algorithm Options = ASME 1989
algorithms, Equation Model =
Dynamic
Lower limit for Reynolds
number. Applicable when
Algorithm Options = ASME 1989
algorithms and Equation Model
= Dynamic
Revision 6.0