Dimensional drawings:
Installation:
1
4
The product contains bracket for wall mounting and spacers for ceiling mounting.
Step 1: Program the loop address (using a hand-held programmer) before any
installation cables are connected.
Dismantle the luminaire by sliding the mounting part as shown in picture.
Fasten the mounting part (with screws from within) to either wall bracket
(supplied), ceiling (with or without supplied spacers), pendulum, wire or
flag bracket.
Pass the loop cables through the cable glands. Connect the loop
Step 2:
cables to terminal blocks, observe correct polarity.
Tighten the cable tie around the cables.
Connect the battery pack. NB: Do not connect the battery pack before
Step 3:
commissioning of the Delta DA Quad loop is imminent.
Step 4: Carefully slide the sign in place.
Slide the two aluminium parts carefully together.
Step 5:
Fasten the two screws (included) as shown in picture.
Step 6:
Fasten the two screws (included) as shown in picture.
Step 7:
The function of the luminaire must be programmed in Delta DA Quad
Step 8:
using FireWin Explorer.
Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway
ExiLED LP
Surface mounted
2
5
3
6
7
Note: In case of loop power
disconnection for a period of more
than one month, the battery must be
disconnected.
GB

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell ExiLED LP

  • Page 1 The function of the luminaire must be programmed in Delta DA Quad Step 8: than one month, the battery must be using FireWin Explorer. disconnected. Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway...
  • Page 2: Technical Description

    EN60598-2-22, EN54-17:2006, EN54-18:2006 IP40 Expected battery lifetime 4 years The ExiLED LP is a self-contained LED exit sign with selftest function. The selftests are initiated from the DA Quad. Selftest functions Every 15 days the luminaire will perform an emergency operation test, this will light the exit sign for approx.
  • Page 3 Merk: Dersom sløyfe- Nødlysets funksjon må programmeres i Delta DA Quad ved bruk av Pkt. 8: spenningen skal frakobles FireWin Explorer. for lengre perioder enn en måned, må batteriet frakobles. Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway...
  • Page 4: Teknisk Beskrivelse

    Klassifisering: EN60598-2-22, EN54-17:2006, EN54-18:2006 IP40 Forventet batterilevetid 4 år ExiLED LP er et desentralisert LED markeringslys med selvtestfunksjon. Selvtestene igangsettes fra DA Quad. Selvtestfunksjoner Hver 15. dag gjennomfører nødlysarmaturen en kort selvtest av nødlysfunksjonen, dette vil belyse skiltet i ca. 60 sekunder med strøm fra batteripakken.
  • Page 5: Installation

    Steg 7: Fäst dom två övre skruvarna (medföljer), se fig 7. period än en månad, skall Steg 8: Nödbelysningens funktion måste programmeras i Delta DA Quad, använd FireWin Explorer. batteriet frånkopplas. Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway...
  • Page 6: Teknisk Beskrivning

    EN60598-2-22, EN54-17:2006, EN54-18:2006 IP40 Förväntad batterilivslängd är 4 år ExiLED LP är en decentraliserad vägledande markering med LED ljuskälla och självtestsystem . Självtestsystemet styrs från DA Quad. Självtestsystemet Var 15:e dag genomför armaturen ett kort självtest av nödljusfunktionen. Testet pågår under ca 60 sekunder med ström från batteriet.
  • Page 7 Kiinnitä valaisin päädystä kuvan 6 mukaisesti. akusto mikäli valaisin ei ole Kiinnitä valaisin toisesta päädystä kuvan 7 mukaisesti liitettynä jännitteelliseen Valaisimen toiminta Delta DA Quad keskuksen suursilmukkaan määritellään FireWin Explorer konfigurointiohjelmalla. suursilmukkaan kuukauteen. Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway...
  • Page 8 Maks 85 % Luokitus: EN60598-2-22, EN54-17:2006, EN54-18:2006 IP40 Akuston odotettu toimintaikä 4 vuotta ExiLED LP on LED yksikkövalaisin jossa on itsetestausominaisuus. Yksikkötestit aktivoidaan Delta DA Quad keskuksesta. Testitoiminnot Turvavalotesti suoritetaan 15 päivän välein, poistumisopastetta valaistaan 60 sekunnin ajan määritellyllä valonvoimakkuudella.