Decimal Constant K; Hexadecimal Constant H - Mitsubishi Electric MELDAS 60 Series Programming Manual

Plc programming
Hide thumbs Also See for MELDAS 60 Series:
Table of Contents

Advertisement

5.3.11 Decimal Constant K

(1) The decimal constant can be used in the following ways.
(a) Timer counter setting value: Designate in the range of 1 to 32767.
(b) Pointer No.: 0 to 159
(c) Bit device digit designation: 1 to 8
(d) Basic command, function command, exclusive command value setting
· 16-bit command: -32768 to 32767
· 32-bit command: -2147483648 to 2147483647
(2) The decimal constant is stored in the binary value (binary) in the PLC.

5.3.12 Hexadecimal Constant H

(1) The hexadecimal constant is used to designate the basic command, function command and
exclusive command values.
· 16-bit command: 0 to FFFF
· 32-bit command: 0 to FFFFFFFF
- 22 -