5.3.8 Index Registers Z

(1) The index registers are used as ornaments for the device (T, C, D, R).
159
165
(2) The index register has a 1-point 16-bit configuration, and can be read and written in 16-bit units.
(3) The data stored in the index register is cleared when the power is turned OFF.
(4) Values that can be stored: Decimal -32768 to 32767
(Note) The CRT display of the index registers Z is as shown below.
MOV
K3
MOV K4X0 D5Z0
Hexadecimal 0 to FFFF
MOV
K3
K4
MOV
X0
- 19 -
5. Explanation of Devices
Z0
D5Z0 Indicates D (5+Z) = D8
Z0
Z0
D5