Download Print this page

Advertisement

SINGLE
Technical
Data Book
Duct for America
(R410A, HP)
Model : Slim Duct - CNH**LDB (AC***BNLDCH/AA), CXH**ADB (AC***BXADCH/AA)
Duct S - CNH**HDB (AC***BNHDCH/AA), CXH**ADB (AC***BXADCH/AA)

Advertisement

loading

Summary of Contents for Samsung Slim Duct-CNH LDB

  • Page 1 SINGLE Technical Data Book Duct for America (R410A, HP) Model : Slim Duct - CNH**LDB (AC***BNLDCH/AA), CXH**ADB (AC***BXADCH/AA) Duct S - CNH**HDB (AC***BNHDCH/AA), CXH**ADB (AC***BXADCH/AA)
  • Page 2 History Version Modification Date Remark Ver.1.0 21. 10. 30 Released 2021 CAC Duct for North America Ver.1.1 Modified the Features & Benefits page 21. 11. 22 Ver.1.2 22. 12. 12 Modified the some data in specification page.
  • Page 3 - World-class energy efficiency Maintain optimal comfort and control with energy and cost-efficient technologies Featuring a suite of energy-optimizing technologies, Samsung CAC Single delivers top-class energy efficiency to support business in saving costs and the environment. Quick, efficient heating and cooling Smart inverter technology offers powerful, quick cooling and heating with minimal electricity consumption, which means real cost savings and less energy waste.
  • Page 4 CAC Single outdoor units offer a selection of pipe directions. The internal pipe connection ports allow four different pipe Samsung is dedicated to supporting comfortable living and working environments based on the strength of directions, supporting a neater, more organized-looking unit upon installation.
  • Page 5 Nomenclature US Code Model Name (1) Classification (5-2) Feature1 (Outdoor Unit) Inv+Side+General Temp Inv+Side+Low Temp Inv+Side+Tropical Temp Inv+Top+Tropical Temp (2) Product Type Indoor Unit (6) Feature Outdoor Unit Flagship Standard (3) Mode Deluxe Universal Premium Cooling Only Heat Pump (7) Version (4) Capacity 2022 X1,000 Btu/h (2 digits)
  • Page 6 Nomenclature Indoor Unit Model Name Buyer (1) Classification (5) Product Notation 1 Way Cassette / Wind-Free 1Way Cassette (Wind-Free) 4 Way Cassette (600x600) (Wind-Free) 4 Way Cassette 360 Cassette (2) Capacity Slim Duct X1,000 Btu/h (3 digits) HSP Duct Ceiling Console AR9500 (Wall Mounted) (3) Version...
  • Page 7 Nomenclature Outdoor Unit Model Name Buyer (1) Classification (5) Feature1 Inv+Side+General Temp Inv+Side+Low Temp Inv+Side+Tropical Temp Inv+Top+Tropical Temp (2) Capacity (6) Feature2 x 1000 Btu/h (3 digits) Flagship Standard Deluxe (3) Version Premium 2022 (7) Rating Voltage 1Φ, 208~230V, 60Hz 3Φ, 400V, 60Hz (4) Product Type Indoor Unit (NASA)
  • Page 8 Line-up Indoor unit Capacity ( kBtu/h) Model Slim Duct Capacity ( kBtu/h) Model 9/12 18/24/30 36/42/48 Duct S Outdoor Unit Capacity ( kBtu/h) Model 1Phase Capacity ( kBtu/h) Model 1Phase...
  • Page 9 Contents Slim Duct Duct S Outdoor Units Installation...
  • Page 10 Slim Duct 1. Specification 2. Summary Table 3. Capacity Table 4. Dimensional Drawing 5. Center of Gravity 6. Electrical Wiring Diagram 7. Sound Data 8. Fan Characteristics...
  • Page 11 750mm and gives benefit of easy installation. Temper any environment with industry-best lightweight design and optimized airflow The new Samsung Slim Duct visually blends into the ceiling while providing powerful cool and warm airflow. It’s also easy to install and maintain in any interior regardless of the surrounding environment with its compact size and weight—the lightest in the industry.
  • Page 12 1. Specification 1. Specification Slim Duct Indoor Unit AC009BNLDCH/AA AC012BNLDCH/AA AC018BNLDCH/AA Model Name Outdoor Unit AC009BXADCH/AA AC012BXADCH/AA AC018BXADCH/AA Indoor Unit CNH09LDB CNH12LDB CNH18LDB US Code Outdoor Unit CXH09ADB CXH12ADB CXH18ADB Mode Heat Pump Heat Pump Heat Pump 0.88 / 2.64 / 3.81 0.94 / 3.52 / 4.10 1.61 / 5.28 / 6.45 Cooling...
  • Page 13 1. Specification Slim Duct Indoor Unit AC009BNLDCH/AA AC012BNLDCH/AA AC018BNLDCH/AA Model Name Outdoor Unit AC009BXADCH/AA AC012BXADCH/AA AC018BXADCH/AA Indoor Unit CNH09LDB CNH12LDB CNH18LDB US Code Outdoor Unit CXH09ADB CXH12ADB CXH18ADB Material Casing Steel Steel Steel Control Infrared remote control AR-EH04U AR-EH04U AR-EH04U System Wired remote control MWR-WG00UN / MWR-SH11UN...
  • Page 14 2. Summary Table 2. Summary Table Slim Duct Performance Characteristics Capacity Airflow Sound Pressure Level Sound Power Level Model Code Weight Fan Speed (Cooling/Heating) Cooling Heating (dBA) (dBA) (lbs) (CFM) (Btu/h) (Btu/h) Max. High 13,000 283 / 283 16,000 CNH09LDB Std.
  • Page 15 3. Capacity Table 3. Capacity Table Slim Duct (1) CNH09LDB(AC009BNLDCH/AA) + CXH09ADB (AC009BXADCH/AA) Cooling TC : Total Capacity, SHC : Sensible Heat Capacity, PI : Power Input Indoor Temperature (℉, DB / WB) Outdoor 68 / 57 72 / 61 77 / 64 80 / 67 82 / 70...
  • Page 16 3. Capacity Table Slim Duct (2) CNH12LDB(AC012BNLDCH/AA) + CXH12ADB (AC012BXADCH/AA) Cooling TC : Total Capacity, SHC : Sensible Heat Capacity, PI : Power Input Indoor Temperature (℉, DB / WB) Outdoor 68 / 57 72 / 61 77 / 64 80 / 67 82 / 70 86 / 72...
  • Page 17 3. Capacity Table Slim Duct (3) CNH18LDB(AC018BNLDCH/AA) + CXH18ADB (AC018BXADCH/AA) Cooling TC : Total Capacity, SHC : Sensible Heat Capacity, PI : Power Input Indoor Temperature (℉, DB / WB) Outdoor 68 / 57 72 / 61 77 / 64 80 / 67 82 / 70 86 / 72...
  • Page 18 4. Dimensional Drawing Slim Duct CNH09LDB(AC009BNLDCH/AA), CNH12LDB(AC012BNLDCH/AA) Units : mm [inches] ④ 134(5-1/4) 766(30-3/16) 20(13/16) (3-1/16) 13(1/2) (1-5/8) (4-15/16) (1-3/8) (5-3/4) (6-1/8) (5-1/8) (5-1/2) 275(10-13/16) 176(6-15/16) 275(10-13/16) (1-5/16) 778(30-5/8) 806(31-3/4) ⑥ ⑦ 945(37-3/16) 7 X 100(3-15/16) = 700(27-9/16) 742(29-3/16) 900(35-7/16) ⑤...
  • Page 19 4. Dimensional Drawing Slim Duct CNH18LDB(AC018BNLDCH/AA) Units : mm [inches] ④ 134(5-1/4) 966(38-1/16) 20(13/16) (3-1/16) 323(12-11/16) 213(8-3/8) (1-5/8) (1/2) (8-9/16) (1-3/8) (2-3/4) (2-13/16) 275(10-13/16) 130(5-1/8) 275(10-13/16) 275(10-13/16) (5/16) 978(38-1/2) 1006(39-5/8) ⑥ ⑦ 1145(45-1/16) 9 X 100(3-15/16) = 900(35-7/16) 942(37-1/16) 1100(43-5/16) ⑤...
  • Page 20 5 5 . . C C ent enter er of Gr of Gra a vity vity Slim Duct Units : mm [inches] Model CNH09/12LDB(AC009/012BNLDCH/AA) 233 [9-3/16] 436 [17-3/16] 100 [3-15/16] 240 [9-7/16] 540 [21-1/4] 100 [3-15/16] CNH18LDB(AC018BNLDCH/AA)
  • Page 21 6 6 . . El Electric ectrical al Wiring Diagr Wiring Diagram Slim Duct MAIN PBA Printed circuit board(MAIN) Electronic Expansion Valve ROOM (10K) Thermistor ROOM in (10K) EXT_CONTROL EXTERNAL CONTROL EVA-IN (10K) Thermistor EVA IN(10K) EVA-OUT (10K) Thermistor EVA OUT(10K) M-BLDC BLDC Motor NOTE...
  • Page 22 7 7 . . S S ound D ound Data Slim Duct Sound Pressure level Unit: dB(A) Model High Discharge Suction CNH09LDB(AC009BNLDCH/AA) Duct Duct CNH12LDB(AC012BNLDCH/AA) 1.5m CNH18LDB(AC018BNLDCH/AA) Microphone • NC Curve 2) CNH12LDB(AC012BNLDCH/AA) 1) CNH09LDB(AC009BNLDCH/AA) 3) CNH18LDB(AC018BNLDCH/AA) NOTE • Specifications may be subject to change without prior notice. - Sound pressure level is obtained in an anechoic room.
  • Page 23 7. Sound Data Slim Duct Sound Power level Unit: dB(A) NOTE Model Cooling • Specifications may be subject to change without prior notice CNH09LDB(AC009BNLDCH/AA) - Sound power level is an absolute value that a sound source generates. CNH12LDB(AC012BNLDCH/AA) - dBA = A-weighted sound power level. CNH18LDB(AC018BNLDCH/AA) - Reference power : 1pW.
  • Page 24 8. 8. F F an Char an Charact acteristics eristics Slim Duct 1) AC009BNLDCH External Static Pressure(inWg) Option Code External Static Pressure(inWg) Option Code 0.01≤ P ≤0.06 01C3FC-1C5407-271A23-370000 0.06<P ≤0.1 01C3FC-1C546B-271A23-370000 Upper limit of HIGH external Upper limit of static pressure HIGH external Lower limit of...
  • Page 25 8. 8. F F an Char an Charact acteristics eristics Slim Duct 2) AC012BNLDCH External Static Pressure(inWg) Option Code External Static Pressure(inWg) Option Code 0.01≤ P ≤0.06 01C3FC-1C54BC-272328-370000 0.06<P ≤0.1 01C3FC-1C55F0-272328-370000 Upper limit of HIGH Upper limit of external HIGH external static pressure Lower limit of...
  • Page 26 8. 8. F F an Char an Charact acteristics eristics Slim Duct 3) AC018BNLDCH External Static Pressure(inWg) Option Code External Static Pressure(inWg) Option Code 0.01≤ P ≤0.06 01C3FC-1C54FB-23343C-370000 0.06<P ≤0.1 01C3FC-1C583D-23343C-370000 HIGH Upper limit of HIGH Upper limit of external external static pressure Lower limit of...
  • Page 27 Duct S 1. Specification 2. Summary Table 3. Capacity Table 4. Dimensional Drawing 5. Center of Gravity 6. Electrical Wiring Diagram 7. Sound Data 8. Temperature and air flow distribution...
  • Page 28 Smart pressure control Overview Samsung Ducted Type units feature a smart pressure Samsung Ducted Type air conditioning units are a smart control system. This system adjusts the fan speed based solution for low-maintenance, consistent cooling and on the external static pressure (ESP), delivering consistent heating performance in any environment.
  • Page 29 1. Specification 1. Specification Duct S Indoor Unit AC009BNHDCH/AA AC012BNHDCH/AA AC018BNHDCH/AA Model Name Outdoor Unit AC009BXADCH/AA AC012BXADCH/AA AC018BXADCH/AA Indoor Unit CNH09HDB CNH12HDB CNH18HDB US Code Outdoor Unit CXH09ADB CXH12ADB CXH18ADB Mode Heat Pump Heat Pump Heat Pump 0.97 / 2.64 / 4.10 1.03 / 3.52 / 4.40 1.76 / 5.28 / 7.03 Cooling...
  • Page 30 1. Specification Duct S Indoor Unit AC009BNHDCH/AA AC012BNHDCH/AA AC018BNHDCH/AA Model Name Outdoor Unit AC009BXADCH/AA AC012BXADCH/AA AC018BXADCH/AA Indoor Unit CNH09HDB CNH12HDB CNH18HDB US Code Outdoor Unit CXH09ADB CXH12ADB CXH18ADB Material Casing Steel Steel Steel Control Infrared remote control AR-EH04U AR-EH04U AR-EH04U System Wired remote control MWR-WG00UN / MWR-SH11UN MWR-WG00UN / MWR-SH11UN MWR-WG00UN / MWR-SH11UN...
  • Page 31 1. Specification Duct S Indoor Unit AC024BNHDCH/AA AC030BNHDCH/AA AC036BNHDCH/AA Model Name Outdoor Unit AC024BXADCH/AA AC030BXADCH/AA AC036BXADCH/AA Indoor Unit CNH24HDB CNH30HDB CNH36HDB US Code Outdoor Unit CXH24ADB CXH30ADB CXH36ADB Mode Heat Pump Heat Pump Heat Pump 2.46 / 7.03 / 9.38 2.52 / 8.79 / 9.96 3.37 / 10.55 / 12.90 Cooling...
  • Page 32 1. Specification Duct S Indoor Unit AC024BNHDCH/AA AC030BNHDCH/AA AC036BNHDCH/AA Model Name Outdoor Unit AC024BXADCH/AA AC030BXADCH/AA AC036BXADCH/AA Indoor Unit CNH24HDB CNH30HDB CNH36HDB US Code Outdoor Unit CXH24ADB CXH30ADB CXH36ADB Material Casing Steel Steel Steel Control Infrared remote control AR-EH04U AR-EH04U AR-EH04U System Wired remote control MWR-WG00UN / MWR-SH11UN MWR-WG00UN / MWR-SH11UN MWR-WG00UN / MWR-SH11UN...
  • Page 33 1. Specification Duct S Indoor Unit AC042BNHDCH/AA AC048BNHDCH/AA Model Name Outdoor Unit AC042BXADCH/AA AC048BXADCH/AA Indoor Unit CNH42HDB CNH48HDB US Code Outdoor Unit CXH42ADB CXH48ADB Mode Heat Pump Heat Pump 3.52 / 12.31 / 13.48 3.66 / 14.07 / 14.95 Cooling Btu/h 12,000 / 42,000 / 46,000 12,500 / 48,000 / 51,000...
  • Page 34 1. Specification Duct S Indoor Unit AC042BNHDCH/AA AC048BNHDCH/AA Model Name Outdoor Unit AC042BXADCH/AA AC048BXADCH/AA Indoor Unit CNH42HDB CNH48HDB US Code Outdoor Unit CXH42ADB CXH48ADB Material Casing Steel Steel Control Infrared remote control AR-EH04U AR-EH04U System Wired remote control MWR-WG00UN / MWR-SH11UN MWR-WG00UN / MWR-SH11UN Indoor Drain Pump...
  • Page 35 2. Summary Table 2. Summary Table Duct S Performance Characteristics Capacity Airflow Sound Pressure Level Sound Power Level Model Code Weight Fan Speed (Cooling/Heating) Cooling Heating (dBA) (dBA) (lbs) (CFM) (Btu/h) (Btu/h) Max. High 14,000 15,000 297 / 297 CNH09HDB Std.
  • Page 36 3 3 . . C C apacity apacity T Tabl able e Duct S (1) CNH09HDB(AC009BNHDCH/AA) + CXH09ADB (AC009BXADCH/AA) Cooling TC : Total Capacity, SHC : Sensible Heat Capacity, PI : Power Input Indoor Temperature (℉, DB / WB) Outdoor 68 / 57 72 / 61 77 / 64...
  • Page 37 3. Capacity Table Duct S (2) CNH12HDB(AC012BNHDCH/AA) + CXH12ADB (AC012BXADCH/AA) Cooling TC : Total Capacity, SHC : Sensible Heat Capacity, PI : Power Input Indoor Temperature (℉, DB / WB) Outdoor 68 / 57 72 / 61 77 / 64 80 / 67 82 / 70 86 / 72...
  • Page 38 3. Capacity Table 3. Capacity Table Duct S (3) CNH18HDB(AC018BNHDCH/AA) + CXH18ADB (AC018BXADCH/AA) Cooling TC : Total Capacity, SHC : Sensible Heat Capacity, PI : Power Input Indoor Temperature (℉, DB / WB) Outdoor 68 / 57 72 / 61 77 / 64 80 / 67 82 / 70...
  • Page 39 3. Capacity Table Duct S (4) CNH24HDB(AC024BNHDCH/AA) + CXH24ADB (AC024BXADCH/AA) Cooling TC : Total Capacity, SHC : Sensible Heat Capacity, PI : Power Input Indoor Temperature (℉, DB / WB) Outdoor 68 / 57 72 / 61 77 / 64 80 / 67 82 / 70 86 / 72...
  • Page 40 3. Capacity Table Duct S (5) CNH30HDB(AC030BNHDCH/AA) + CXH30ADB (AC030BXADCH/AA) Cooling TC : Total Capacity, SHC : Sensible Heat Capacity, PI : Power Input Indoor Temperature (℉, DB / WB) Outdoor 68 / 57 72 / 61 77 / 64 80 / 67 82 / 70 86 / 72...
  • Page 41 3. Capacity Table Duct S (6) CNH36HDB(AC036BNHDCH/AA) + CXH36ADB (AC036BXADCH/AA) Cooling TC : Total Capacity, SHC : Sensible Heat Capacity, PI : Power Input Indoor Temperature (℉, DB / WB) Outdoor 68 / 57 72 / 61 77 / 64 80 / 67 82 / 70 86 / 72...
  • Page 42 3. Capacity Table Duct S (7) CNH42HDB(AC042BNHDCH/AA) + CXH42ADB (AC042BXADCH/AA) Cooling TC : Total Capacity, SHC : Sensible Heat Capacity, PI : Power Input Indoor Temperature (℉, DB / WB) Outdoor 68 / 57 72 / 61 77 / 64 80 / 67 82 / 70 86 / 72...
  • Page 43 3. Capacity Table Duct S (8) CNH48HDB(AC048BNHDCH/AA) + CXH48ADB (AC048BXADCH/AA) Cooling TC : Total Capacity, SHC : Sensible Heat Capacity, PI : Power Input Indoor Temperature (℉, DB / WB) Outdoor 68 / 57 72 / 61 77 / 64 80 / 67 82 / 70 86 / 72...
  • Page 44 4. Dimensional Drawing 4. Dimensional Drawing Duct S CNH09HDB (AC009BNHDCH/AA), CNH12HDB (AC012BNHDCH/AA) Units : mm (inches) Name Description Liquid pipe connection Φ6.35 mm(1/4") Gas pipe connection Φ9.52 mm(3/8") Drain pipe connection 3/4"[OD26.67mm(1.05")] Power supply connection Air discharge flange Air suction flange Hook M8~M10...
  • Page 45 4. Dimensional Drawing Duct S CNH18HDB (AC018BNHDCH/AA), CNH24HDB (AC024BNHDCH/AA), CNH30HDB (AC030BNHDCH/AA) Units : mm (inches) Description Name CNH18HDB (AC018BNHDCH/AA) CNH24HDB (AC024BNHDCH/AA) CNH30HDB (AC030BNHDCH/AA) Liquid pipe connection Φ6.35 mm(1/4") Φ9.52 mm(3/8") Gas pipe connection Φ12.7 mm(1/2") Φ15.88 mm(5/8") Drain pipe connection 3/4"[OD26.67mm(1.05")] Power supply connection Air discharge flange...
  • Page 46 4 4 . . Dimensional Dr Dimensional Dra a wing wing Duct S CNH36HDB (AC036BNHDCH/AA), CNH42HDB (AC042BNHDCH/AA), CNH48HDB (AC048BNHDCH/AA) Units : mm (inches) Name Description Liquid pipe connection Φ9.52 mm(3/8") Gas pipe connection Φ15.88 mm(5/8") Drain pipe connection 3/4"[OD26.67mm(1.05")] Power supply connection Air discharge flange Air suction flange Hook...
  • Page 47 5 5 . . C C ent enter er of Gr of Gra a vity vity Duct S Units : mm [inches] Model CNH09HDB (AC009BNHDCH/AA) 125 [4-15/16] CNH12HDB (AC012BNHDCH/AA) [27-9/16] [14] [35-7/16] [15-15/16] [9-15/16] CNH18HDB (AC018BNHDCH/AA) 1250 CNH24HDB (AC024BNHDCH/AA) 125 [4-15/16] [27-9/16] [10-7/16] [49-3/16]...
  • Page 48 6 6 . . El Electric ectrical al Wiring Diagr Wiring Diagram Duct S MAIN PBA Printed circuit board(MAIN) Electronic Expansion Valve ROOM (10K) Thermistor ROOM in (10K) EXT_CONTROL EXTERNAL CONTROL EVA-IN (10K) Thermistor EVA IN(10K) EVA-OUT (10K) Thermistor EVA OUT(10K) M-BLDC BLDC Motor DISCHARGE(10K) Thermistor DISCHARGE...
  • Page 49 7 7 . . S S ound D ound Data Duct S Sound Pressure level Unit: dB(A) Model High Discharge Suction Duct Duct CNH09HDB (AC009BNHDCH/AA) CNH12HDB (AC012BNHDCH/AA) CNH18HDB (AC018BNHDCH/AA) CNH24HDB (AC024BNHDCH/AA) Microphone • NC Curve 1) CNH09HDB (AC009BNHDCH/AA) 2) CNH12HDB (AC012BNHDCH/AA) NC 60 NC 60 High...
  • Page 50 7 7 . . S S ound D ound Data Duct S Sound Pressure level Unit: dB(A) Model High Discharge Suction Duct Duct CNH30HDB (AC030BNHDCH/AA) CNH36HDB (AC036BNHDCH/AA) CNH42HDB (AC042BNHDCH/AA) CNH48HDB (AC048BNHDCH/AA) Microphone • NC Curve 2) CNH36HDB (AC036BNHDCH/AA) 1) CNH30HDB (AC030BNHDCH/AA) 3) CNH42HDB (AC042BNHDCH/AA) 4) CNH48HDB (AC048BNHDCH/AA) NOTE...
  • Page 51 7. Sound Data Duct S Sound Power level Unit: dB(A) NOTE Model Cooling • Specifications may be subject to change without prior notice CNH09HDB (AC009BNHDCH/AA) - Sound power level is an absolute value that a sound source generates. CNH12HDB (AC012BNHDCH/AA) - dBA = A-weighted sound power level.
  • Page 52 7 7 . . S S ound D ound Data Duct S Sound Power level Unit: dB(A) NOTE Model Cooling • Specifications may be subject to change without prior notice CNH30HDB (AC030BNHDCH/AA) - Sound power level is an absolute value that a sound source generates.
  • Page 53 8. Temperature and air flow distribution Duct S CNH09HDB (AC009BNHDCH/AA) Option Code Option Code External Static Pressure(inWg) External Static Pressure(inWg) 0.1≤ P ≤0.2 01B3FC-1C50D3-271A23-370000 0.2< P ≤0.3 01B3FC-1C5466-271A23-370000 Upper limit of external static pressure HIGH HIGH Upper limit of external static pressure Lower limit of external...
  • Page 54 8. Temperature and air flow distribution 8. Temperature and air flow distribution Duct S CNH12HDB (AC012BNHDCH/AA) External Static Pressure(inWg) Option Code External Static Pressure(inWg) Option Code 0.1≤ P ≤0.2 01B3FC-1C5404-272328-370000 0.2< P ≤0.3 01B3FC-1C5477-272328-370000 Upper limit of external HIGH Upper limit of static pressure external static pressure...
  • Page 55 8. Temperature and air flow distribution Duct S CNH18HDB (AC018BNHDCH/AA) External Static Pressure(inWg) Option Code External Static Pressure(inWg) Option Code 0.1≤ P ≤0.2 01B3FC-1C5416-2F343C-370020 0.2< P ≤0.3 01B3FC-1C547A-2F343C-370020 Upper limit of external static pressure Upper limit of HIGH external static pressure HIGH Lower limit of Lower limit of...
  • Page 56 8. Temperature and air flow distribution Duct S CNH18HDB (AC018BNHDCH/AA) External Static Pressure(inWg) Option Code 0.7< P ≤0.8 01B3FC-1C5E50-2F343C-370020 Upper limit of external static pressure HIGH Lower limit of external static pressure 1000 1100 Air Flow Rate [CFM]...
  • Page 57 8. Temperature and air flow distribution Duct S CNH24HDB (AC024BNHDCH/AA) External Static Pressure(inWg) Option Code External Static Pressure(inWg) Option Code 0.1≤ P ≤0.2 01B3FC-1C542A-27484F-370020 0.2< P ≤0.3 01B3FC-1C548E-27484F-370020 Upper limit of external HIGH static pressure Upper limit of external Lower limit of static pressure HIGH external...
  • Page 58 8. Temperature and air flow distribution Duct S CNH24HDB (AC024BNHDCH/AA) Option Code External Static Pressure(inWg) 0.7< P ≤0.8 01B3FC-1C5D5F-27484F-370020 Upper limit of external static pressure HIGH Lower limit of external static pressure 1000 1100 1200 Air Flow Rate [CFM]...
  • Page 59 8. Temperature and air flow distribution Duct S CNH30HDB (AC030BNHDCH/AA) Option Code Option Code External Static Pressure(inWg) External Static Pressure(inWg) 0.1≤ P ≤0.2 01B3FC-1C547B-275A5E-370020 0.2< P ≤0.3 01B3FC-1C54DE-275A5E-370020 Upper limit of HIGH external static pressure Upper limit of HIGH external static pressure Lower limit of Lower limit of...
  • Page 60 8. Temperature and air flow distribution Duct S CNH30HDB (AC030BNHDCH/AA) Option Code External Static Pressure(inWg) 0.7< P ≤0.8 01B3FC-1C5D3E-275A5E-370020 Upper limit of HIGH external static pressure Lower limit of external static pressure 1000 1100 1200 13 00 Air Flow Rate [CFM]...
  • Page 61 8. Temperature and air flow distribution Duct S CNH36HDB (AC036BNHDCH/AA) External Static Pressure(inWg) Option Code External Static Pressure(inWg) Option Code 2.5≤ P ≤5 01B3FC-1C5439-276975-370045 5< P ≤7.5 01B3FC-1C548C-276975-370045 Upper limit of external HIGH static pressure Upper limit of external HIGH static pressure Lower limit of external...
  • Page 62 8. Temperature and air flow distribution Duct S CNH36HDB (AC036BNHDCH/AA) External Static Pressure(inWg) Option Code 17.5< P ≤20 01B3FC-1C59A6-276975-370045 Upper limit of external HIGH static pressure Lower limit of external static pressure 1000 1100 1200 1300 1400 1500 1600 Air Flow Rate [CFM]...
  • Page 63 8. Temperature and air flow distribution Duct S CNH42HDB (AC042BNHDCH/AA) Option Code Option Code External Static Pressure(inWg) External Static Pressure(inWg) 2.5≤ P ≤5 01B3FC-1C5449-277D8A-370045 5< P ≤7.5 01B3FC-1C549C-277D8A-370045 Upper limit of external HIGH static pressure Upper limit of HIGH external static pressure Lower limit of Lower limit of...
  • Page 64 8. Temperature and air flow distribution Duct S CNH42HDB (AC042BNHDCH/AA) External Static Pressure(inWg) Option Code 17.5< P ≤20 01B3FC-1C59B6-277D8A-370045 Upper limit external HIGH static pressure Lower limit of external static pressure 1000 1100 1200 1300 1400 1500 1600 1700 Air Flow Rate [CFM]...
  • Page 65 8. Temperature and air flow distribution Duct S CNH48HDB (AC048BNHDCH/AA) External Static Pressure(inWg) Option Code External Static Pressure(inWg) Option Code 2.5≤ P ≤5 01B3FC-1C545A-278C9B-370045 5< P ≤7.5 01B3FC-1C54AD-278C9B-370045 Upper limit of external HIGH static pressure Upper limit of external HIGH static pressure Lower limit of external...
  • Page 66 8. Temperature and air flow distribution Duct S CNH48HDB (AC048BNHDCH/AA) Option Code External Static Pressure(inWg) 17.5< P ≤20 01B3FC-1C59C7-278C9B-370045 Upper limit of external HIGH static pressure Lower limit of external static pressure 1000 1100 1200 1300 1400 1500 1600 1700 Air Flow Rate [CFM]...
  • Page 67: Table Of Contents

    Outdoor Units 1. Summary Table 2. Dimensional Drawing 3. Center of Gravity 4. Electrical Wiring Diagram 5. Sound Data 6. Capacity Correction 7. Operation Range 8. Piping Diagram...
  • Page 68: Summary Table

    1. Summary Table 1. Summary Table Outdoor Units Performance Characteristics Capacity Sound Pressure Level (dBA) Sound Power Net Size Net Weight Airflow Model Code (Btu/h) (WxHxD inch) (lbs) (CFM) Level (dBA) Cooling Heating 9,000 CXH09ADB (AC009BXADCH/AA) 31.10 x 21.57 x 11.22 74.3 1,059 12,000...
  • Page 69: Dimensional Drawing

    2. Dimensional Drawing Outdoor Units CXH09ADB (AC009BXADCH/AA), CXH12ADB (AC012BXADCH/AA) Units : mm [inches] 601.7 (23-3/4) (11-1/4) (31-1/8) (4-15/16) (5-7/8) 601.7 (3-9/16) (23-3/4) (14-3/16) Name Description Refrigerant gas pipe Φ 9.52mm(3/8") Refrigerant liquid pipe Φ 6.35mm(1/4") Drain Hole...
  • Page 70 2. Dimensional D awing Outdoor Units CXH18ADB (AC018BXADCH/AA) Units : mm [inches] Name Description Refrigerant liquid pipe Φ 12.7mm(1/2") Refrigerant gas pipe Φ 6.35mm(1/4") Drain hole...
  • Page 71 2. Dimensional Drawing 2. Dimensional Drawing Outdoor Units CXH24ADB (AC024BXADCH/AA), CXH30ADB (AC030BXADCH/AA) Units : mm [inches] [22-7/8] Description Name CXH24ADB (AC024BXADCH/AA) CXH30ADB (AC030BXADCH/AA) Refrigerant liquid pipe Φ 6.35mm(1/4") Φ 9.52mm(3/8") Refrigerant gas pipe Φ 15.88mm(5/8") Piping intake knockout hole Front / Side / Rear / Bottom Power wiring conduit Front / Side / Rear , Φ...
  • Page 72 2. Dimensional Drawing Outdoor Units CXH36ADB (AC036BXADCH/AA), CXH42ADB (AC042BXADCH/AA), CXH48ADB (AC048BXADCH/AA) Units : mm [inches] [22-7/8] Name Description Refrigerant liquid pipe Φ 9.52mm(3/8") Refrigerant gas pipe Φ 15.88mm(5/8") Piping intake knockout hole Front / Side / Rear / Bottom Power wiring conduit Front / Side / Rear , Φ...
  • Page 73: Center Of Gravity

    3. Center of Gravity Outdoor Units CXH09ADB (AC009BXADCH/AA), CXH12ADB (AC012BXADCH/AA) Units : mm [inches] [9-1/8 [6-1/2] The position of foundation bolt CXH18ADB (AC018BXADCH/AA) Units : mm [inches]...
  • Page 74 3. Center of Gravity 3. Center of Gravity Outdoor Units CXH24ADB (AC024BXADCH/AA), CXH30ADB (AC030BXADCH/AA) Units : mm [inches] CXH36ADB (AC036BXADCH/AA), CXH42ADB (AC042BXADCH/AA), CXH48ADB (AC048BXADCH/AA) Units : mm [inches]...
  • Page 75 4. Electrical Wiring Diagram Outdoor Units CXH09ADB (AC009BXADCH/AA), CXH12ADB (AC012BXADCH/AA) MAIN PCB Printed circuit board(MAIN) Electronic Expansion Valve INVERTER PCB Printed circuit board(INVERTER) M-BLDC BLDC Motor EMI PCB Printed circuit board(EMI) OLP-TEMP Thermistor OLP NOTE • This wiring diagram applies only to the outdoor unit. •...
  • Page 76 4. Electrical Wiring Diagram 4. Electrical Wiring Diagram Outdoor Units CXH18ADB (AC018BXADCH/AA) MAIN PCB Printed circuit board(MAIN) Electronic Expansion Valve INVERTER PCB Printed circuit board(INVERTER) M-BLDC BLDC Motor EMI PCB Printed circuit board(EMI) OLP-TEMP Thermistor OLP NOTE • This wiring diagram applies only to the outdoor unit. •...
  • Page 77: Electrical Wiring Diagram

    4. Electrical Wiring Diagram Outdoor Units CXH24ADB (AC024BXADCH/AA), CXH30ADB (AC030BXADCH/AA), CXH36ADB (AC036BXADCH/AA) CXH42ADB (AC042BXADCH/AA), CXH48ADB (AC048BXADCH/AA) BLDC Brushless DC Motor COMP CHECK Outdoor COMP Operating Check 4WAY 4way Valve ERROR CHECK Outdoor Error Check NOTE • This wiring diagram applies only to the outdoor unit. •...
  • Page 78: Sound Data

    5. Sound Data 5. Sound Data Outdoor Units Sound Pressure level Unit: dB(A) Model Cooling Heating Microphone CXH09ADB (AC009BXADCH/AA) CXH12ADB (AC012BXADCH/AA) 1.5m CXH18ADB (AC018BXADCH/AA) Front CXH24ADB (AC024BXADCH/AA) • NC Curve 2) CXH12ADB (AC012BXADCH/AA) 1) CXH09ADB (AC009BXADCH/AA) 3) CXH18ADB (AC018BXADCH/AA) 4) CXH24ADB (AC024BXADCH/AA) NOTE •...
  • Page 79 5. Sound Data Outdoor Units Sound Pressure level Unit: dB(A) Model Cooling Heating Microphone CXH30ADB (AC030BXADCH/AA) CXH36ADB (AC036BXADCH/AA) 1.5m CXH42ADB (AC042BXADCH/AA) Front CXH48ADB (AC048BXADCH/AA) • NC Curve 2) CXH36ADB (AC036BXADCH/AA) 1) CXH30ADB (AC030BXADCH/AA) 3) CXH42ADB (AC042BXADCH/AA) 4) CXH48ADB (AC048BXADCH/AA) NOTE •...
  • Page 80 5 5 . . S S ound D ound Data Outdoor Units Sound Power level Unit: dB(A) NOTE Model Cooling • Specifications may be subject to change without prior notice CXH09ADB (AC009BXADCH/AA) - Sound power level is an absolute value that a sound source generates.
  • Page 81 5 5 . . S S ound D ound Data Outdoor Units Sound Power level Unit: dB(A) NOTE Model Cooling • Specifications may be subject to change without prior notice CXH30ADB (AC030BXADCH/AA) - Sound power level is an absolute value that a sound source generates.
  • Page 82: Capacity Correction

    6. Capacity Correction Outdoor Units CNH09LDB(AC009BNLDCH/AA)+CXH09ADB(AC009BXADCH/AA) CNH12LDB(AC012BNLDCH/AA)+CXH12ADB(AC012BXADCH/AA) CNH09HDB(AC009BNHDCH/AA)+CXH09ADB(AC009BXADCH/AA) CNH12HDB(AC012BNHDCH/AA)+CXH12ADB(AC012BXADCH/AA) Cooling Pipe Length (ft) 32.8 49.2 65.6 24.6 49.2 0.95 0.93 32.8 0.98 0.95 0.93 16.4 1.00 0.98 0.95 0.93 0.98 1.00 0.95 0.93 0.97 -16.4 1.00 0.95 0.93 0.95 -32.8 0.94 0.92 -49.2...
  • Page 83 6. Capacity Correction Outdoor Units CNH18LDB(AC018BNLDCH/AA)+CXH18ADB(AC018BXADCH/AA) CNH18HDB(AC018BNHDCH/AA)+CXH18ADB(AC018BXADCH/AA) CNH24HDB(AC024BNHDCH/AA)+CXH24ADB(AC024BXADCH/AA) CNH30HDB(AC030BNHDCH/AA)+CXH30ADB(AC030BXADCH/AA) Cooling Pipe Length (ft) 24.6 32.8 49.2 65.6 82.0 98.4 114.8 131.2 147.6 164.0 98.4 0.94 0.93 0.92 0.91 0.90 82.0 0.96 0.94 0.93 0.92 0.91 0.90 65.6 0.97 0.96 0.94 0.93 0.92 0.91...
  • Page 84 6. Capacity Correction Outdoor Units CNH36HDB(AC036BNHDCH/AA)+CXH36ADB(AC036BXADCH/AA) CNH42HDB(AC042BNHDCH/AA)+CXH42ADB(AC042BXADCH/AA) CNH48HDB(AC048BNHDCH/AA)+CXH48ADB(AC048BXADCH/AA) Cooling Pipe Length (ft) 16.4 32.8 49.2 65.6 82.0 98.4 114.8 131.2 147.6 164.0 180.4 196.9 213.3 229.7 246.1 98.4 0.96 0.95 0.94 0.93 0.92 0.91 0.91 0.90 0.89 0.88 82.0 0.97 0.96 0.95 0.94...
  • Page 85: Operation Range

    7 7 . . Oper Operation Range ation Range Outdoor Units Mode Indoor temperature Outdoor temperature Indoor humidity 18℃ to 32℃ -18℃ to 50℃ Cooling 80% or less (64℉ to 90℉) (0℉ to 122℉) 18℃ to 32℃ -18℃ to 50℃ Drying (64℉...
  • Page 86: Piping Diagram

    8. Piping Diagram Outdoor Units CNH09LDB(AC009BNLDCH/AA)+CXH09ADB(AC009BXADCH/AA) CNH12LDB(AC012BNLDCH/AA)+CXH12ADB(AC012BXADCH/AA) CNH09HDB(AC009HNLDCH/AA)+CXH09ADB(AC009BXADCH/AA) CNH12HDB(AC012HNLDCH/AA)+CXH12ADB(AC012BXADCH/AA) OUTDOOR UNIT INDOOR UNIT Thermistor- Thermistor- IDU Heat Exchanger Mid Heat (T_IM) Exchanger (T_II) Service Valve- Heat Exchanger - Pipe Indoor unit (SV_G) (HX_ID) Thermistor- Indoor Room (T_IR) Outdoor Fan Motor1 (OFM1) Electronic Indoor Fan Motor Expansion Valve-...
  • Page 87 8. Piping Diagram Outdoor Units CNH18LDB(AC018BNLDCH/AA)+CXH18ADB(AC018BXADCH/AA) CNH18HDB(AC018BNHDCH/AA)+CXH18ADB(AC018BXADCH/AA) OUTDOOR UNIT INDOOR UNIT Thermistor- Thermistor- IDU Heat Exchanger Mid Heat (T_IM) Exchanger (T_II) Service Valve- Heat Exchanger - Pipe Indoor unit (SV_G) (HX_ID) Thermistor- Indoor Room (T_IR) Outdoor Fan Motor1 (OFM1) Electronic Indoor Fan Motor Expansion Valve- (IFM)
  • Page 88 8. Piping Diagram Outdoor Units CNH24HDB(AC024BNHDCH/AA)+CXH24ADB(AC024BXADCH/AA) CNH30HDB(AC030BNHDCH/AA)+CXH30ADB(AC030BXADCH/AA) OUTDOOR UNIT INDOOR UNIT Thermistor- Thermistor- IDU Heat Exchanger Mid Heat (T_IM) Exchanger (T_II) Service Valve- Heat Exchanger - Pipe Indoor unit (SV_G) (HX_ID) Thermistor- Indoor Room (T_IR) Outdoor Fan Motor1 (OFM1) Electronic Indoor Fan Motor Expansion Valve- (IFM)
  • Page 89 8. Piping Diagram Outdoor Units CNH36HDB(AC036BNHDCH/AA)+CXH36ADB(AC036BXADCH/AA) CNH42HDB(AC042BNHDCH/AA)+CXH42ADB(AC042BXADCH/AA) CNH48HDB(AC048BNHDCH/AA)+CXH48ADB(AC048BXADCH/AA) OUTDOOR UNIT INDOOR UNIT Thermistor- Thermistor- IDU Heat Exchanger Mid Heat (T_IM) Exchanger (T_II) Service Valve- Heat Exchanger - Gas Pipe Indoor unit (SV_G) (HX_ID) Thermistor- Indoor Room (T_IR) Outdoor Fan Motor1 (OFM2) Outdoor Fan Motor1 (OFM1) Electronic Indoor Fan Motor...
  • Page 90 Installation Duct Spacing requirements Space requirements for installation & service. Construction Standard for Inspection opening An inspection opening is required for service and unit replacement. 1) If the ceiling is a grid type, an inspection opening is not required. 2) If the ceiling is plaster board, an inspection opening is required. The size of the opening will vary based on the height inside the ceiling.
  • Page 91 Installation Duct Installing the indoor unit 4 Screw eight nuts to the suspension bolts making space for hanging the indoor unit. When deciding on the location of the air conditioner with the NOTE owner, the following restrictions must be taken into account •...
  • Page 92 Installation Duct Installing the drain hose and drain pipe With the drain pump Push the supplied drain hose as far as possible over the drain The drain pipe should be installed within 11.81inch(300mm) to socket. 21.65inch(550mm) from the flexible hose and then lift down 2 Tighten the metal clamp as shown in the picture.
  • Page 93 Installation Duct Connecting the power and AC***BNHDCH communication cables Indoor Unit CAUTION F1 F2 • Always remember to connect the refrigerant pipes before performing the electric connections. When disconnecting the system, always disconnect the electric cables before disconnecting the refrigerant pipes. Cable clamp CAUTION •...
  • Page 94 Installation Duct AC***BNHDCH Communication: M3.5 screw AC power: M4 screw 0.35(9) 0.50(12.6) 0.30(7.5) 0.39(9.8) Unit : inch(mm) Tightening torque lbf·ft (kgf • cm) M3.5 0.58 to 0.87 (8.0 to 12.0) 0.87 to 1.30 (12.0 to 18.0) • Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord.
  • Page 95 Protection wall Stereo Computer etc Outdoor Unit 7.87 inch(200mm) Air Guide Duct (This product is not provided by Samsung) CAUTION • Depending on the condition of the power supply, unstable power or voltage may cause malfunction of parts or control system (example: on a boat or places...
  • Page 96 • Check the condition of the product periodically. – Check the installation site every 3 months and perform anti-corrosion treatment such as R-Pro supplied by SAMSUNG (Code : MOK-220SA) or 34.65 (880) 1.93 (49) commercial water repellent grease and wax, etc., C Type based on the product condition.
  • Page 97 Installation Outdoor Units Minimum clearances for the outdoor unit When installing 1 outdoor unit 11.81 23.62 23.62 (600) 23.62 (600) Unit : inch (mm) (300) or more or more (600) or more or more 11.81 (300) or more 11.81 (300) or more 78.74 (2000) 11.81 23.62...
  • Page 98 Installation Outdoor Units Moving the outdoor unit with wire rope AC018BXADCH [Unit : inch(mm)] Anchor bolt hole 1 Before carrying the outdoor unit, fasten two wire ropes of 26.25 ft (8m) or longer, as shown in the figure. 2 To prevent damages or scratches effectively, insert a piece of cloth between the outdoor unit and the ropes.
  • Page 99 Installation Outdoor Units CAUTION • AC018BXADCH • Make sure that the wall can support the weights of the rack and the outdoor unit. – Drill conduit holes on the side cabinet. (knock out holes) • Install the rack close to the column as much as possible. •...
  • Page 100 Installation Outdoor Units Main power 2 Insert the cables through the conduits, and then fix the Communication cable cable Outdoor-to-indoor power cable conduits to the conduit plate with the lock nuts. MCCB Earthing 3 Apply silicone to the end of the hose to prevent rain from entering the hose.
  • Page 101 Installation Outdoor Units Connecting the main power cable When using ELB for AC018BXADCH (1-phase) Power Supply Electrical component box MCCB 2(N) 1(L) Cable clamp Cable tie Communication Outdoor to indoor Main power cable power cable cable The appearance of the unit may be different from the picture Indoor Unit depending on the model.
  • Page 102 Installation Outdoor Units • AC024/030/036/042/048BXADCH (1-phase) CAUTION [Unit : inch(mm)] • You should connect the power cable into the power cable terminal and fasten it with a clamp. AC power : Communication : M4 screw • The unbalanced power must be maintained within 2% M4 screw of supply rating.
  • Page 103 Installation Outdoor Units Single phase Model Outdoor Indoor Rated input current of Power Source the power Outdoor Indoor conversion equipment FAN1(A) FAN2(A) FAN(A) AC009BN1DCH 0.26 AC009BNHDCH 2.10 AC009BXADCH AC009BNJDCH 0.42 0.49 10.9 15.0 AC009BNLDCH 1.06 AC009BNNDCH 0.30 208~230V/60Hz AC012BN1DCH 0.26 AC012BNHDCH 2.10 10.9...
  • Page 104 Installation Outdoor Units Silence mode controller wiring diagram with NOTE External controller • RLA is based on AHRI 210/240 cooling standard condition [Indoor temp. : 26.7 °C / 80 °F(DB) / 19.46 °C / • AC009/012/018BXADCH 67 °F(WB), Outdoor temp. : 35 °C / 95 °F(DB)] •...
  • Page 105 Installation Outdoor Units Connecting the outdoor-to-indoor power cable • AC024/030/036/042/048BXADCH and the communication cable • AC009/012BXADCH Indoor Unit Indoor Unit Outdoor Unit F1 F2 1(L) 2(N) L N 1(L) 2(N) L F1 F2 Cable tie Communication Main power cable Outdoor to indoor cable power cable NOTE...
  • Page 106 Installation Outdoor Units Nominal Nominal dimensions dimensions Standard Standard Standard Min. Min. Max. Standard Min. Allowance Allowance Allowance Allowance for cable for screw dimension dimension dimension dimension [mm(inch)] [mm(inch)] [mm(inch)] [mm(inch)] [mm2(inch2)] [mm(inch)] [mm(inch)] [mm(inch)] [mm(inch)] (inch)] (inch)] (inch)] [mm(inch)] (inch)] +0.2 (+0.007) 4(3/8)
  • Page 107 Installation Outdoor Units Outdoor-to-indoor power and communication cables specifications • Indoor unit : Duct(AC***BNL***, AC***BNH***) Indoor power supply Power supply Max/Min (V) Indoor power cable 0.0023 inch²↑ 1Φ, 208-230V~, 60Hz ±10% (1.5mm ↑), 3 w ires Communication cable 0.0012 inch²↑ (0.75mm ↑), 2 wires • Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord.
  • Page 108 2022. 12 Ver.1.2 Samsung Electronics Co., LTD. Head Office (Suwon Korea) 129, Samsung-Ro, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea 16677 Website : www.samsung.com, https://partnerhub.samsung.com Email : airconditioner@samsung.com Images and data in this book may subject to change without prior notice.