SINGLE
Technical
Data Book
for America
(R410A, HP)
Model :

Advertisement

Table of Contents
loading

Summary of Contents for Samsung Slim Duct CNH LDB Series

  • Page 1 SINGLE Technical Data Book for America (R410A, HP) Model :...
  • Page 2 History Version Modification Date Remark...
  • Page 3: Features And Benefits

    - World-class energy efficiency Maintain optimal comfort and control with energy and cost-efficient technologies Featuring a suite of energy-optimizing technologies, Samsung CAC Single delivers top-class energy efficiency to support business in saving costs and the environment. Quick, efficient heating and cooling Smart inverter technology offers powerful, quick cooling and heating with minimal electricity consumption, which means real cost savings and less energy waste.
  • Page 4 CAC Single outdoor units offer a selection of pipe directions. The internal pipe connection ports allow four different pipe Samsung is dedicated to supporting comfortable living directions, supporting a neater, more organized-looking unit and working environments based on the strength of upon installation.
  • Page 5 Nomenclature US Code Model Name...
  • Page 6 Nomenclature Indoor Unit Model Name Buyer (1) Classification (5) Product Notation (2) Capacity X1,000 Btu/h (3 digits) (3) Version (6) Feature (4) Product Type Flagship Standard Outdoor Unit Deluxe Premium (7) Rating Voltage (8) Mode...
  • Page 7: Outdoor Unit

    Nomenclature Outdoor Unit Model Name Buyer (1) Classification (5) Feature1 (2) Capacity (6) Feature2 x 1000 Btu/h (3 digits) (3) Version (7) Rating Voltage (4) Product Type Outdoor Unit (NASA) (8) Mode Cooling Only(R410A) Cooling Only(R22)
  • Page 8: Indoor Unit

    Line-up Indoor unit Capacity ( kBtu/h) Model Outdoor Unit Capacity ( kBtu/h) Model 1Phase...
  • Page 9 Contents...
  • Page 10 1. Specification 2. Summary Table 3. Capacity Table 4. Dimensional Drawing 5. Center of Gravity 6. Electrical Wiring Diagram 7. Sound Data 8. Fan Characteristics...
  • Page 11 Features & Benefits Rear Side Air Inlet Bottom Side Air Inlet Suction Duct Suction Duct...
  • Page 12: Specification

    1. Specification 1. Specification...
  • Page 13 1. Specification NOTE Specification may be subject to change without prior notice. Performances are based on the following test conditions. Select wire size based on the value of MCA Sound pressure level is obtained in an anechoic room. - Sound pressure level is a relative value, depending on the distance and acoustic environment. - Sound pressure level may differ depending on operation condition.
  • Page 14: Summary Table

    2. Summary Table 2. Summary Table Performance Characteristics Capacity Airflow Sound Pressure Level Sound Power Level Model Code Weight Fan Speed (Cooling/Heating) Cooling Heating (dBA) (dBA) (lbs) (CFM) (Btu/h) (Btu/h) Max. Std. Min. Max. Std. Min. Max. Std. Min. NOTE Electric Characteristics Model Outdoor Unit...
  • Page 15: Capacity Table

    3. Capacity Table 3. Capacity Table Cooling Heating NOTE The performance table shows the average value of each conditions.
  • Page 16 3. Capacity Table Cooling Heating NOTE The performance table shows the average value of each conditions.
  • Page 17 3. Capacity Table Cooling Heating NOTE The performance table shows the average value of each conditions.
  • Page 18: Dimensional Drawing

    4. Dimensional Drawing 7 X 100 = 700 Name Description Refrigerant Liquid Pipe Refrigerant Gas Pipe Condensate Drain Power & Comm. Wiring Conduits Supply Air Flange Return Air Flange Hook...
  • Page 19 4. Dimensional Drawing 1006 1145 9 X 100 = 900 1100 Name Description Refrigerant Liquid Pipe Refrigerant Gas Pipe Condensate Drain Power & Comm. Wiring Conduits Supply Air Flange Return Air Flange Hook...
  • Page 20 5 5 . . C C ent enter er of Gr of Gra a vity vity Model...
  • Page 21 6 6 . . El Electric ectrical al Wiring Diagr Wiring Diagram NOTE This wiring diagram applies only to the Indoor unit. Symbols show as follow : blk: black, red: red, blu: blue, wht: white, yel: yellow, brn: brown, sky: skyblue: grn: green For connection wiring indoor-outdoor transmission F1-F2, indoor-wired remote controller transmission F3-F4.
  • Page 22: Sound Pressure Level

    7 7 . . S S ound D ound Data Sound Pressure level Model Discharge Suction Duct Duct 1.5m Microphone NC Curve NOTE Specifications may be subject to change without prior notice. - Sound pressure level is obtained in an anechoic room. - Sound pressure level is a relative value, depending on the distance and acoustic environment.
  • Page 23: Sound Data

    7. Sound Data Sound Power level NOTE Model Specifications may be subject to change without prior notice - Sound power level is an absolute value that a sound source generates. - dBA = A-weighted sound power level. - Reference power : 1pW. - Measured according to ISO 3741.
  • Page 24 8. 8. F F an Char an Charact acteristics eristics 1) AC009BNLDCH Option Code Option Code External Static Pressure(in External Static Pressure(in 1C3FC-1C5407-271A23-370000 0.06< 1C3FC-1C546B-271A23-370000 Upper limit of HIGH external Upper limit of static pressure HIGH external Lower limit of Lower limit of static pressure external...
  • Page 25 8. 8. F F an Char an Charact acteristics eristics 2) AC012BNLDCH Option Code Option Code External Static Pressure(in External Static Pressure(in 01C3FC-1C54BC-272328-370000 0.06< 01C3FC-1C55F0-272328-370000 Upper limit of HIGH Upper limit of external HIGH external static pressure Lower limit of static pressure Lower limit of external...
  • Page 26 8. 8. F F an Char an Charact acteristics eristics 3) AC018BNLDCH Option Code Option Code External Static Pressure(in External Static Pressure(in 01C3FC-1C54FB-23343C-370000 0.06< 01C3FC-1C583D-23343C-370000 HIGH Upper limit of HIGH Upper limit of external external static pressure Lower limit of static pressure Lower limit of external...
  • Page 27: Outdoor Units

    Outdoor Units 1. Summary Table 2. Dimensional Drawing 5. Sound Data 6. Capacity Correction 7. Operation Range 8. Piping Diagram...
  • Page 28 1 1 . . S S ummary ummary T Tabl able e Outdoor Units Performance Characteristics Sound Pressure Level (dBA) Sound Power Capacity Net Size Net Weight Airflow Model Code (WxHxD inch) (lbs) (CFM) Level (dBA) Cooling Heating ,000 ,000 ,000 NOTE Sound power level is based on cooling operation.
  • Page 29 2. Dimensional Drawing Outdoor Units Name Description Refrigerant gas pipe Refrigerant liquid pipe Drain Hole...
  • Page 30 2. Dimensional D awing Outdoor Units Name Description Refrigerant liquid pipe Refrigerant gas pipe Drain hole...
  • Page 31 3 3 . . C C ent enter er of Gr of Gra a vity vity Outdoor Units...
  • Page 32: Electrical Wiring Diagram

    4. Electrical Wiring Diagram Outdoor Units MAIN PCB INVERTER PCB M-BLDC BLDC Motor EMI PCB OLP-TEMP Thermistor OLP NOTE This wiring diagram applies only to the outdoor unit. For connection wiring indoor-outdoor transmission F1-F2, outdoor-outdoor transmission OF1-OF2, refer to the installation manual.
  • Page 33 4 4 . . El Electric ectrical al Wiring Diagr Wiring Diagram Outdoor Units MAIN PCB INVERTER PCB M-BLDC BLDC Motor EMI PCB OLP-TEMP Thermistor OLP NOTE This wiring diagram applies only to the outdoor unit. For connection wiring indoor-outdoor transmission F1-F2, outdoor-outdoor transmission OF1-OF2, refer to the installation manual.
  • Page 34 5 5 . . S S ound D ound Data Outdoor Units Sound Pressure level Model Cooling Heating Microphone 1.5m Front NC Curve NOTE Specifications may be subject to change without prior notice. - Sound pressure level is obtained in an anechoic room. - Sound pressure level is a relative value, depending on the distance and acoustic environment.
  • Page 35 5. Sound Data Outdoor Units Sound Power level NOTE Model Specifications may be subject to change without prior notice - Sound power level is an absolute value that a sound source generates. - dBA = A-weighted sound power level. - Reference power : 1pW. - Measured according to ISO 3741.
  • Page 36: Capacity Correction

    6. Capacity Correction Outdoor Units Cooling Pipe Length (ft) 32.8 49.2 65.6 49.2 0.93 0.95 32.8 0.98 0.95 0.93 16.4 1.00 0.93 0.98 0.95 0.98 1.00 0.95 0.93 0.97 -16.4 1.00 0.95 0.93 -32.8 0.95 0.94 0.92 -49.2 0.93 0.91 Heating Pipe Length (ft) 32.8...
  • Page 37 6. Capacity Correction Outdoor Units Cooling Pipe Length (ft) 32.8 49.2 65.6 82.0 98.4 114.8 131.2 147.6 164.0 98.4 0.94 0.93 0.92 0.91 0.90 82.0 0.96 0.94 0.93 0.92 0.91 0.90 65.6 0.97 0.96 0.94 0.93 0.92 0.91 0.90 49.2 0.98 0.97 0.96...
  • Page 38 7 7 . . Oper Operation Range ation Range Outdoor Units Mode Indoor temperature Outdoor temperature Indoor humidity Cooling 80% or less 80% or less Drying Heating NOTE The assumed installation conditions are follows - The pipe length(including elbow) is 7.5m(24.6ft). - The level difference is 0 m.
  • Page 39: Piping Diagram

    8. Piping Diagram Outdoor Units OUTDOOR UNIT INDOOR UNIT Thermistor- Thermistor- IDU Heat Exchanger Mid Heat (T_IM) Exchanger (T_II) Service Valve- Heat Exchanger - Pipe Indoor unit (SV_G) (HX_ID) Thermistor- Indoor Room (T_IR) Outdoor Fan Motor1 (OFM1) Electronic Indoor Fan Motor Expansion Valve- (IFM) Main...
  • Page 40 8. Piping Diagram Outdoor Units OUTDOOR UNIT INDOOR UNIT Thermistor- Thermistor- IDU Heat Exchanger Mid Heat (T_IM) Exchanger (T_II) Service Valve- Heat Exchanger - Pipe Indoor unit (SV_G) (HX_ID) Thermistor- Indoor Room (T_IR) Outdoor Fan Motor1 (OFM1) Electronic Indoor Fan Motor Expansion Valve- (IFM) Main...
  • Page 41: Installation

    Installation Duct Spacing requirements Construction Standard for Inspection opening ceiling. a. Height is more than 1.64ft (0.5m): Only “B” [Inspection for PBA] is applied. 0.79 inch (20 mm) or more 0.79 inch (20 mm) or more Unit Width(W) "B"=19.69 inch (500 mm) "A"=W+3.94 inch (100 mm) •...
  • Page 42: Installing The Indoor Unit

    Installation Duct Installing the indoor unit 4 Screw eight nuts to the suspension bolts making space for hanging the indoor unit. When deciding on the location of the air conditioner with the NOTE owner, the following restrictions must be taken into account •...
  • Page 43: Installing The Drain Hose And Drain Pipe

    Installation Duct Installing the drain hose and drain pipe With the drain pump Push the supplied drain hose as far as possible over the drain The drain pipe should be installed within 11.81inch(300mm) to socket. 21.65inch(550mm) from the flexible hose and then lift down 2 Tighten the metal clamp as shown in the picture.
  • Page 44: Connecting The Power And Communication Cables

    Installation Duct Connecting the power and AC***BNLDCH communication cables Indoor Unit CAUTION L(L1) N(L2) • Always remember to connect the refrigerant pipes before performing the electric connections. When disconnecting the system, always disconnect the electric cables before disconnecting the refrigerant pipes. Cable clamp CAUTION •...
  • Page 45 Installation Duct AC***BNLDCH AC power: M4 screw Communication: M3.5 screw 0.40(10.1) 0.45(11.4) 0.41(10.3) 0.54(13.8) Unit : inch(mm) Tightening torque lbf·ft (kgf • cm) M3.5 0.58 to 0.87 (8.0 to 12.0) 0.87 to 1.30 (12.0 to 18.0) • Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord.
  • Page 46: Choosing The Installation Location

    Protection wall Stereo Computer etc Outdoor Unit 7.87 inch(200mm) Air Guide Duct (This product is not provided by Samsung) CAUTION • Depending on the condition of the power supply, unstable power or voltage may cause malfunction of parts or control system (example: on a boat or places...
  • Page 47 • Check the condition of the product periodically. – Check the installation site every 3 months and perform anti-corrosion treatment such as R-Pro supplied by SAMSUNG (Code : MOK-220SA) or 34.65 (880) 1.93 (49) commercial water repellent grease and wax, etc., based on the product condition.
  • Page 48 Installation Minimum clearances for the outdoor unit When installing 1 outdoor unit 11.81 23.62 23.62 (600) 23.62 (600) Unit : inch (mm) (300) or more or more (600) or more or more 11.81 (300) or more 11.81 (300) or more 78.74 (2000) 11.81 23.62...
  • Page 49: Fixing The Outdoor Unit In Place

    Installation Moving the outdoor unit with wire rope AC018BXADCH [Unit : inch(mm)] Anchor bolt hole 1 Before carrying the outdoor unit, fasten two wire ropes of 26.25 ft (8m) or longer, as shown in the figure. 2 To prevent damages or scratches effectively, insert a piece of cloth between the outdoor unit and the ropes.
  • Page 50: Connecting The Power Cables, Communication Cable, And Controllers

    Installation CAUTION • AC BXADCH – Drill conduit holes on the side cabinet. (knock • Make sure that the wall can support the weights of the out holes) rack and the outdoor unit. • Install the rack close to the column as much as possible. •...
  • Page 51 Installation Main power Communication cable 2 Insert the cables through the conduits, and then fix the cable Outdoor-to-indoor power cable conduits to the conduit plate with the lock nuts. MCCB Earthing 3 Apply silicone to the end of the hose to prevent rain from entering the hose.
  • Page 52 Installation Connecting the main power cable When using ELB for AC009BXADCH, AC012BXADCH (1-phase) Power Supply Electrical component box MCCB 2(N) 1(L) Communication Outdoor to indoor Main power cable power cable cable The appearance of the unit may be different from the picture Indoor Unit depending on the model.
  • Page 53 Installation CAUTION Main power terminal block specifications • You should connect the power cable into the power • AC 018BXADCH (1-phase) cable terminal and fasten it with a clamp. [Unit : inch(mm)] • The unbalanced power must be maintained within 2% Communication: of supply rating.
  • Page 54 Installation Single phase Model Outdoor Indoor Rated input current of Power Source the power Outdoor Indoor conversion equipment FAN1(A) FAN2(A) FAN(A) AC009BN1DCH 0.26 15.0 AC009BNHDCH 2.10 10.9 15.0 AC009BXADCH AC009BNJDCH 0.42 0.49 15.0 AC009BNLDCH 1.06 15.0 AC009BNNDCH 0.30 15.0 AC012BN1DCH 0.26 15.0 AC012BNHDCH...
  • Page 55 Installation Silence mode controller wiring diagram with NOTE External controller • RLA is based on AHRI 210/240 cooling standard condition [Indoor temp. : 26.7 °C / 80 °F(DB) / 19.46 °C / • 67 °F(WB), Outdoor temp. : 35 °C / 95 °F(DB)] •...
  • Page 56 Installation Connecting the outdoor-to-indoor power cable NOTE and the communication cable • Lay the electrical wiring so that the front cover does not rise up when doing wiring work and attach the front cover securely. • • Ground wire for the indoor unit and outdoor unit connection cable must be clamped to a soft copper tin-plated eyelet terminal with M4 screw hole(NOT SUPPLIED WITH UNIT ACCESSORIES).
  • Page 57 Installation Nominal Nominal dimensions dimensions Standard Standard Standard Min. Min. Max. Standard Min. Allowance Allowance Allowance Allowance for cable for screw dimension dimension dimension dimension [mm(inch)] [mm(inch)] [mm(inch)] [mm(inch)] [mm2(inch2)] [mm(inch)] [mm(inch)] [mm(inch)] [mm(inch)] (inch)] (inch)] (inch)] [mm(inch)] (inch)] +0.2 (+0.007) 4(3/8) 9.5(3/8) 20 (3/4) 4.3 (3/16)
  • Page 58 Installation Outdoor-to-indoor power and communication cables specifications • Indoor unit : Duct(AC***BNL***, AC***BNH***) Indoor power supply Power supply Max/Min (V) Indoor power cable 0.0023 inch 1 , 208-230V , 60Hz ±10% (1.5mm ), 3 wires Communication cable 0.0012 inch (0.75mm ), 2 wires •...
  • Page 59 Samsung Electronics Co., LTD.