Disassembly Guide; Indoor Unit - Medium & High Static Ducted Unit - Bosch Climate 5000 Series Service Manual

Ducted type (medium & high static) air conditioner / heat pump
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

Service Manual

8 Disassembly Guide

This part is for reference, the photos may have slight diff erences with
your machine.
8.1 Indoor Unit - Medium & High Static Ducted Unit
8.1.1 How to remove the electrical control box
Step 1: Remove 5 screws to remove the electrical control box cover.
Figure 102
Step 2: Disconnect connectors for fan motor, room temperature sensor
and evaporator temperature sensor.
Figure 103
Step 3: Remove 2 screws to disassemble the electrical control box.
8 0 |
5 screws
room temperature
sensor
and evaporator
temperature sensor
Fan motor
Bosch Climate 5000 Series Ducted Type (Medium & High Static) Air Conditioner / Heat Pump (11.2022)
Figure 104
8.1.2 How to remove the PCB
Step 1: Remove the electrical control box cover by following previous
section.
Step 2: Pull out all the connectors and remove 1 screw to disconnect the
ground wire.
Figure 105
2 screws