4.3.4 Component overview Depot Charge Box GEN2
The main components as can be seen with an open front door:
A
SPD (F4) AC Power Supply
B
MCB (F5) AC Power Supply
C
Fuse (F1,F2) DC Circuit
D
SPD (F3) DC Power Circuit
4.4
Technical functioning
4.4.1 Normal operation
Normal positions of the different switches and breakers when the charger is in operation (idle; not charg-
ing):
Power Cabinet
Main switch (A): Vertical ("1")
•
MCB (Q17) AC power supply for ACM (B): up
•
•
RCD (Q13) control (C): up
RCD (Q12) redundant control (D): up
•
Depot Charge Box GEN2
SPD (F2) AC Power Supply: green
•
MCB (F1) AC Power Supply: up
•
•
Fuse (F3,F4) DC Precharge Circuit: not blown
SPD (F5) DC Power Circuit: green
•
4.4.2 Switch the charger system on/off
In case it is necessary to switch off the charger system, this can be done by turning off the main switch
(A in Power Cabinet, see section Component overview Power Cabinet on page 15):
1. Open the front door.
D O C U M E N T N O. : 9 A K K 10 8 4 67 A 6 6 3 5 - E N V 0. 3 | D AT E : 2 0/ 1 2 / 2 0 2 2
H V C - R 1 0 7 / 1 6 0 V 2 E -B U S C H A R G E R - U S E R M A N U A L
PA G E 16 O F 2 0