8) Serial Port Configuration

This page is used to select a communi-
cation protocol among listed ones.
(1) Serial Port Selection
Administrator selects a serial port to
set. DX-VS1UE has three serial ports.
Serial#1 and Serial#2 are RS232-C
interface ports, and Serial#3 is a
RS422/RS485 interface port.
(2) Select Attached Device
Administrator selects a communication protocol that an attached external de-
vice satisfies among listed protocols.
Manual Setting
If you can't find protocol for your external device in the list, you can define the protocol by selecting
"manual setting" and setting values to control parameters and pan/tilt/zoom commands. For detailed
information, refer to the "PTZ Command for Manual Script" explained at the next page.
※ Although this machine is equipped with two or more communication protocols that control
pan/tilt/zoom cameras of other companies, operation to all the cameras of other companies
and Pan/tilt/zoom operation are not guaranteed. In addition, it has not answered the inquiry
about combination with the camera etc. of other companies.
(3) Control Parameters
You can also set control parameters such as "Baud Rate", "Stop Bits", "Data Bits", and "Parity
Check" according to the setting of the connected digital recorder or external camera.