TECHNICAL DATA
Rated voltage
Working pressure max
Operating temperature max
Residual solution in tank max
Gross mass (empty)
Gross mass (full)
Flow rate
Brass nozzle
Scatter
Stream
Plastic nozzle
Scatter
Tank capacity
Size of filler strainer mesh
A-weighted emission sound pressure level at the operator's position
BATTERY AND CHARGER
Model
ABS1858B
Battery pack
Charger
L1815R, L1815G, L1820R, L1825R, L1830R, L1830RHD,
L1830R-X5, L1840R, L1850R, L1850R-X5, L1860R,
Compatible
L1860RHD, L1860R-X5, L1860B, L1890R, L1890RHD,
battery packs
L1820S, L1820SHD, A18FB2, L1840S, A18B4,
L1840SHD, A18FB4, L1850SHD, A18FB5
Compatible
BL18S, BL18DPS, BL18DP2-X5, BL1218, BLK1218,
chargers
REPLACEMENT PARTS
Wand with nozzles
Hose and trigger assembly
Basket filter and O-ring
Pickup tube
INTENDED USE
The backpack sprayer is intended for outdoor or indoor use in a well-
ventilated area.
The product should be used only in domestic application by adults who have
received adequate training on the hazards and preventative measures to be
taken while using the product.
The product is designed for spraying consumer-grade home and garden
chemicals, such as disinfectants, insecticides, fungicides, weed killers, and
fertilizers. The product may also be used to water plants.
Do not use the product for any other purpose.
WARNING! If the product is used for herbicide or insecticide applications,
do not repurpose it for use with disinfectants. Obtain a second unit of the
product for dedicated use with disinfectants only.
BACKPACK SPRAYER
ADVBPS14
-
A18FB4
-
BL18S
BL18DP-X5, AL1218G, AL18G
313253001
564941001
313531001
314217001
GENERAL PRODUCT SAFETY WARNINGS
WARNING! Read all safety warnings, instructions, illustrations and
specifications provided with this power tool. Failure to follow all instructions
listed below may result in electric shock, fire, and/or serious injury.
Save all warnings and instruction for future reference.
The term "power tool" in the warnings refers to your mains-operated (corded)
product or battery-operated (cordless) product.
WORK AREA SAFETY
Keep work area clean and well lit. Cluttered or dark areas invite accidents.
Do not operate power tools in explosive atmospheres, such as in the
presence of flammable liquids, gases or dust. Power tools create sparks
which may ignite the dust or fumes.
Keep children and bystanders away while operating a power tool.
Distractions can cause you to lose control.
ELECTRICAL SAFETY
Power tool plugs must match the outlet. Never modify the plug in any
way. Do not use any adapter plugs with earthed (grounded) power tools.
Unmodified plugs and matching outlets will reduce risk of electric shock.
Avoid body contact with earthed or grounded surfaces, such as pipes,
radiators, ranges and refrigerators. There is an increased risk of electric
shock if your body is earthed or grounded.
Do not expose power tools to rain or wet conditions. Water entering a
power tool will increase the risk of electric shock.
Do not abuse the cord. Never use the cord for carrying, pulling or
unplugging the power tool. Keep cord away from heat, oil, sharp edges or
moving parts. Damaged or entangled cords increase the risk of electric shock.
When operating a power tool outdoors, use an extension cord suitable
for outdoor use. Use of a cord suitable for outdoor use reduces the risk of
electric shock.
If operating a power tool in a damp location is unavoidable, use a residual
current device (RCD) protected supply. Use of an RCD reduces the risk of
electric shock.
PERSONAL SAFETY
Stay alert, watch what you are doing and use common sense when
operating a power tool. Do not use a power tool while you are tired
or under the influence of drugs, alcohol or medication. A moment of
inattention while operating power tools may result in serious personal injury.
Use personal protective equipment. Always wear eye protection.
Protective equipment such as a dust mask, non-skid safety shoes, hard hat
or hearing protection used for appropriate conditions will reduce personal
injuries.
35
ABS1858B/ADVBPS14
18 V / 58 V d.c.
90PSI / 6.2 bar (static pressure)
40° C
<0.25 L
6.2 kg (without battery)
23 kg
0.5-1.0 L/min at 2.4-5.3 bar
0.7-1.5 L/min at 0.8-2.5 bar
0.7-1.4 L/min at 1.2-3.9 bar
15 L / 4 gal.
1.3 mm
70 dB(A)
35