Specifications

Item
Power supply
LoRa
Ethernet
4G LTE
Wi-Fi
Bluetooth
Storage
USB connector
NFC reader
SIM
Key/button
LED
Working
temperature &
Humidity
HCH
Specification
DC power supply, 12~24V/0.5A or USB Type-C input: 5V2A
Note: For USB Type C input, not support the adaptors with battery fast
charging protocol such as PD/QC/AFC etc.
LoRa Private network
868/915MHz ISM band
Network Capacity:
1 Central Hub + typical 32 devices (60s interval, 24STD+ 8RTR)
l
Max Capacity: 64 max. (120s interval, 56STD+ 8RTR)
l
1 Router(RTR mode) support max 16 end devices(STD mode)
l
Network Hops
Max. 2 hops. (End device to Router to Central Hub.)
l
Range/ distance
Up to 1km (external to external antenna, line of sight.)
l
Note:
STD: work as a standard end device.
l
RTR: work as a Router can bypass end device data.
l
10/100M adaptive/Central Hub setting/WAN
LTE FDD, CAT-4; Mini-PCIE interface; GPS (Reserved)
IEEE 802.11n, 2.4 GHz; BLE & Wi-Fi combine module.
BLE 5.0 (HW reserved); BLE & Wi-Fi combine module.
Micro-SD card, 32GB memory; For local datalog
USB Type C, backup Power input. Reserved for vehicle application by car
power adaptor. See Power Supply item.
13.56 MHz, HW reserved.
1.8V/3.0V, plug-in card; Mini(Standard) card, 2FF. SIM card must be at
least a 4GB datacard.
Power button: On/Off;
Reset buttons: Hot reset <5s; factory reset ≥5s
Power/RF/LAN/Wi-Fi/LTE: Green
Fault: Red
-4° to 140° F (-20° to 60°C);
20%-90% RH, non-condensing