• AFTER REPAIRING THE UNIT, PERFORM THE FOLLOWING STEPS BEFORE RETURNING TO CUSTOMER.
1.
Open tray.
2.
While pressing the DISPLAY button, press the Z button, the x button, and the . button in that order.
3.
Check to make sure that the STANDBY indicator lights up and remove the AC cord from its socket.
4.
Insert cushion in tray and close tray manually. (See figure below.)
cushion
tray
5.
Fix tray into place with tape in two places. (See figure below.)
tape
4