Inspection; Warning Devices - Bosch Rexroth CytroPac Operating Instructions Manual

Hydraulic power unit
Hide thumbs Also See for Rexroth CytroPac:
Table of Contents

Advertisement

58/80
CytroPac | Maintenance and repair
Bosch Rexroth AG, Edition 07.2022, RE 51055-B
10�2 Inspection
Bosch Rexroth recommends documenting the inspection results
• so that considering functionality and economy, the inspection and maintenance
intervals can be adjusted to the actual operating conditions.
• by comparing the documented values, you can identify faults at an early point in
time.
▶ Before any inspection work, clean the hydraulic power unit as necessary.
▶ Carry out the following visual inspections for clearly apparent defects:
– Illegible notices or warning signs
– Leakage
– Loose and/or missing parts
– Indications of external force effects
10�3 Warning devices
The hydraulic power unit is equipped with an LED strip for status indication in the
"Premium" and "Premium M12" configurations:
• Normal operation: LED strip illuminated in green
• Standby:
LED strip flashes green
• Warning:
LED strip illuminated in green and flashing yellow
• Error:
LED strip illuminated in red and flashing yellow
For a detailed description of the flashing codes, see the commissioning
instructions 51055-IB in the chapter "Status LED".
The error message can be read out precisely via the Mini-USB service interface
and IndraWorks Ds or the higher-level control.