Overview Of The Electrical Interfaces; Basic" Sensor Technology Version; Premium" And "Premium M12" Sensor Technology Versions - Bosch Rexroth CytroPac Operating Instructions Manual

Hydraulic power unit
Hide thumbs Also See for Rexroth CytroPac:
Table of Contents

Advertisement

36/80
CytroPac | Assembly
Bosch Rexroth AG, Edition 07.2022, RE 51055-B
7�5 Overview of the electrical interfaces
Fig� 15: Overview of the electrical interfaces
1 Filling level and temperature sensor
2 Filter contamination sensor 100 %
3 Filter contamination sensor 75 %
4 16X1
1)
: (M12 x 1) sensor evaluation,
wired at the plant
5 12X1: Feed-in/voltage supply
7�5�1 "Basic" sensor technology version
The "Basic" sensor technology version is equipped with the following connections:
• Port 12X1: Feed-in/voltage supply
• Port 15X1: 24 V interface (M12 x 1, 8-pole)
• Port 14X1: Mini USB service interface
• Port 22X1
3)
: STO interface
7�5�2 "Premium" and "Premium M12" sensor technology versions
The "Premium" and "Premium M12" sensor technology versions are also equipped
with the following connections:
• Port 16X1
: (M12 x 1) sensor evaluation, wired at the plant
1)
• Port 21X1
2)
: Multi-Ethernet interface, network input
• Port 21X2
2)
: Multi-Ethernet interface, network input
1)
For the "Premium" and "Premium M12" expansion stages, the sensors are factory-wired
and connected via a cable set to port 16X1.
2)
The "Premium" and "Premium M12" configurations differ only in the device socket used,
see Fig. 25.
3)
Optionally available
6 21X1
1)
: Multi-Ethernet interface
7 21X2
2)
: Multi-Ethernet interface
8 22X1
3)
: STO interface
9 15X1: 24 V interface
(M12 x 1, 8-pole)
10 14X1: Mini USB service interface

Advertisement

Table of Contents
loading