Download Print this page

Advertisement

Quick Links

AquaStation
Chilled
the
Instruction Book - Suits all LWA300 Models

Advertisement

loading

Summary of Contents for Breville AquaStation Chilled

  • Page 1 AquaStation Chilled ™ Instruction Book - Suits all LWA300 Models...
  • Page 2: Table Of Contents

    Filter performance SAFETY FIRST may vary based on local water conditions. IMPORTANT At Breville we are very safety conscious. We design and SAFEGUARDS manufacture consumer products with the safety of you,...
  • Page 3 • The AquaStation™ Chilled is not in use and before must be used only with the cleaning and storing. Breville filter supplied or replacement product code • Do not remove the water tank LWA063. from the power base during operation.
  • Page 4 • Any procedure not listed in • This appliance is for household this instruction book should use only. Do not use this be performed at an authorised appliance for anything other Breville Service Centre. than its intended use. Do not...
  • Page 5 • Any maintenance other than Do not use outdoors. Misuse cleaning should be performed may cause injury at an authorised Breville Service Centre • This appliance can be used by children aged from 8 years • It is recommended to regularly and above and persons with inspect the appliance.
  • Page 6 • Cleaning and user maintenance BREVILLE ASSIST™ PLUG shall not be made by children • Your Breville appliance comes without supervision. with a unique Assist™ Plug, conveniently designed with a SPECIFIC INSTRUCTIONS finger hole in the power plug FOR WATER FILTER for easy and safe removal from •...
  • Page 7: Components

    20cm cup clearance height with tray in place, 23cm height if drip tray removed I. Detachable magnetic drip tray J. Removable tray grill for cleaning K. Non-marking, non-slip feet Not Shown • Breville Assist™ Plug • Drain Plug & Cap (Located underneath unit)
  • Page 8 Control Panel 15ºC 10ºC AMBIENT START/STOP FILTER 5ºC RESET Water droplet light flashes 3 times then illuminates white when ready or when dispensing water. The light extinguishes when START | STOP READY in standby mode. 5°C, 10°C & 15°C Light illuminates against the selected cold temperature.
  • Page 9 NOTES • Cold water temperature settings are measured in the chilling chamber not the dispensed temperature at the spout or in the cup. • When dispensing ambient water, if START/ STOP is not pressed to stop water flow, dispensing will automatically stop after 60 seconds.
  • Page 10: Features

    *The filter change alert is set at 90 days or approximately 200L of water, whichever CHILLED? comes first, with performance based on typical The Breville AquaStation™ Chilled when used municipal drinking water quality, however, with the Activ360™ 4-stage fast flow water water quality may vary considerably from one...
  • Page 11 BPA Free* All parts that come into direct contact with water are made from BPA Free* materials * Breville makes its BPA Free claim for this product based on independent laboratory testing performed for all the food contact plastic materials of the product per EU Commission regulation No 10/2011.
  • Page 12: Assembly

    Discard the collected water. • Do not wash the filter or insert into the 5. Repeat steps 3-5 until all the water in the water tank until ‘Flushing the Breville tank has been dispensed. The unit will stop AquaStation’ and ‘Preparing the Activ360 dispensing when the water level is too low Filter’...
  • Page 13 NEW FILTER SHAKE FILTER NEW FILTER SHAKE FILTER SHAKE FILTER FILTER RESET 1. Lift the water tank from the unit, remove the FILTER RESET lid and set aside. Lifting by the ring, remove AMBIENT the filter cartridge from the filter holder and discard any remaining water inside the water tank.
  • Page 14 • The filter is not washable. NOTE • Use only the original Breville filter For replacement water filters, visit Breville.com specifically intended for use with the or contact Breville Customer Service.
  • Page 15: Operation

    Operation OPERATING YOUR NOTE AQUASTATION CHILLED Discard any filtered water that has been left 1. Ensure the water tank is in place and that sitting for several days or more. This will the water filter cartridge is correctly fitted ensure you have cleaner, great-tasting water.
  • Page 16 NOTE NOTE If the START/STOP button is not pressed If the START/STOP button is not pressed a second time to stop, dispensing will a second time to stop, dispensing will automatically stop after 60 seconds. automatically stop after 60 seconds. NOTE NOTE Always ensure the correct sized cup/glass is...
  • Page 17: Care, Cleaning & Storage

    4. Replace the rubber plug (refer to figure c) and screw the plastic drain plug cap back NOTE on (refer to figure d). For Breville's Stainless Steel Cleaner & Polish, visit Breville.com or contact Breville Customer Service. CLEANING THE WATER SPOUT...
  • Page 18 CLEANING THE DRIP TRAY The drip tray should be removed, emptied and cleaned after each use. Empty the tray before removing the top grill and cleaning. 1. Remove the drip tray from the unit and discard any water. 2. Separate the top grill from the drip tray. 3.
  • Page 19: Troubleshooting

    Change the filter if required, turn Indicator light flashing reset has not been actioned the FUNCTION dial to “FILTER RESET” and press the START/ STOP button once to reset. If you cannot remedy problems by using the troubleshooting chart above, contact Breville Customer Service.
  • Page 20 Web: www.breville.com Breville, the Breville logo, AquaStation and Activ360 are trademarks of Breville Pty Ltd. All other brands may be trademarks of their respective owners. Breville's products are distributed in New Zealand under licence A.B.N. 98 000 092 928. Approved by the appropriate electrical supply authorities.

This manual is also suitable for:

Aquastation lwa300