NEC NEAX 2400 IPX Manual page 114

Fusion network
Hide thumbs Also See for NEAX 2400 IPX:
Table of Contents

Advertisement

Connection link (for Data)
C_RT: 11
TCL=4
STEP 3: ACTK
Assign the Connection Trunk data for B-ch and D-ch.
Example:
(When using 512kbps (8ch) TS as Connection link)
Connection trunk (B-ch)
C_RT: 10
Connection link (D-ch)
C_RT: 11
C_RT: 11
Note:
Set the switch on the FCH card depending on the transmission speed.
See
"CHAPTER 4
STEP 4: AFCH
Assign the FCCH number for each FCCH.
FCHN: 2 (FCCH number)
STEP 5: AFPC
Assign the FCCS routing data.
FPC: 1 (FPC of the adjacent node)
CRT: 10
STEP 6: ACAN
Assign the CIC number to the connection trunk.
FPC: 1
STEP 7: AFRT
Assign the FCCH Controlled Connection Route data.
FCHN: 2
STEP 8: AFPC
Assign the FCCS routing data.
FPC: 1 (FPC of the adjacent node)FCCH: 1 (with FCCH)
CRT: 10
LSG=13
TK: 1-664
CLENS: LEN for the SDT
TK: 1-8
CLENS: LEN for the FCH
TK: 9-16
CLENS: LEN for the SDT
INSTALLATION" for more information on switch settings.
FCIC: 1-664
CLENS: LEN of the connection trunk
CRT: 10
NDA-24299
Assignment of FCH Related Data
FCHEN: LEN of FCCH
FCCH: 1 (with FCCH)
FCHN: 2
FCHN: 2
DATA PROGRAMMING
CHAPTER 5
Page 99
Revision 1.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents