1.2

Safety precautions

Fitting & Retrofitting
▶ Risk of fire!
Exercise due care when soldering and welding.
▶ This storage tank must only be fitted or refitted by a
competent installer.
Operation
▶ In order to ensure trouble-free operation, read
these instructions carefully.
▶ Risk of scalding!
During operation of this storage tank temperatures
over 60 °C can occur.
Servicing
▶ Only original spare parts must be used with this
appliance.
Installing the buffer tank
The buffer tank should be installed on a flat floor
surface. Ensure that the bottom of the tank is fully in
contact with the floor. Care should be taken not to
damage the metal casing of the tank.
Ensure that the floor is dry and the outside of the
buffer tank cannot get wet during its lifetime. The
insulation will be damaged if left in contact with water.
If the buffer tank cannot be mounted on a flat floor
surface (for example if the tank is mounted on a wall
frame) the tank must first be placed on top of a
suitable metal plate. The bottom of the tank must be
fully in contact with the metal plate and completely
cover the tank bottom.
BT 50 HP – 6 720 821 241 (2017/09)
2

Product information

2.1

Use

The storage tank is designed to act as a buffer for the heating system and
is ideally suited to heat pump applications.
WARNING:
▶ Do not use the storage tank in conjunction with
permeable pipe work.
2.2

Intended use

The storage tank must only be filled with heating water and must only be
used in sealed heating systems which are designed for use with heat
pumps. Any other use is an infringement of use for intended purpose.
Any damage that may result is excluded from liability.
Not for use as a method of potable hot water (Domestic Hot Water)
storage.
2.3

Scope for delivery

5
Fig. 1
Primary water storage tank
[1]
V
/ V
1
2
[2]
Sensor cable retaining clip
[3]
R
/ R
1
2
[4]
Sensor pocket (for flow temperature sensor)
[5]
Insulation
The sensor pocket is for the installation of the heat pump
temperature sensor.
Product information
33