5
8. EACH SETTING AND ADJUSTMENT
8.1 NECESSARY ITEMS TO BE NOTED
After repairing, be sure to check the version of the firmware, and if it is not the latest one,
update to the latest version.
In addition, be sure to reset the unit to the default settings, using Factory Reset mode, before
returning the repaired product to the user.
Perform the corresponding task(s) in the described order after any of the following parts is replaced:
• MAIN UCOM (CDJ1 Assy: IC1002)
• EEPROM (IFPW Assy: IC104)
• Component parts of the JOG dial section
8.2 HOW TO PROGRAM COPY FOR USB CONTROLLER
1. Check that the controller is OFF.
2. While holding the LOOP OUT 1 and VINYL 1 buttons pressed, set the Power switch of the unit to ON.
Note: NEVER release the above-mentioned two buttons while the FUNCTION LED is lit.
3. After making sure that the FUNCTION LED is unlit, set the Power switch of the unit to OFF.
LOOP OUT 1 button : S1227
VINYL 1 button
: S1208
FUNCTION LED
: D1203
Note: If copying fails, the FUNCTION LED will flash at intervals of 0.25 sec.
5
6
• Confirmation of the version of the firmware
• Updating to the latest version of the firmware
• Copying the program for the USB controller
• Updating to the latest version of the firmware
• Copying the program for the USB controller
• JOG dial rotation load adjustment
DDJ-ERGO-V
6
7
7
8
A
B
C
D
E
F
43
8