Cisco ASR 1004 Quick Start Manual page 34

Cisco systems router user manual
Hide thumbs Also See for ASR 1004:
Table of Contents

Advertisement

Figure 14
Cisco ASR 1004 Router DC Power Supply Terminal Block
1
Ground lug and positive lead wire
Terminal block and positive stud
2
Earth grounding symbol
3
Step 8
Tighten the Kepnut screw (use the screwdriver to tighten the ground screw in the terminal block to a torque of 8 in-lbs
/ 4 per.) and repeat the same steps for the positive ground stud and wire.
Secure the wires coming in from the terminal block so that they cannot be disturbed by casual contact.
Note
Use tie wraps to secure the wires, so that the wires are not pulled from the terminal block by casual contact. Ti-wrap
Step 9
studs are located below the power supply terminal block.
Step 10 Replace the terminal block plastic cover, which slides over the terminal block; then tighten the screws (tighten the screw
to a torque of 5 in-lbs / 1 per.).
34
1
5
4
2
3
4
Washer
Kepnut screw
5

Hide quick links: