Testing; Removing The Filter Cover & Filter; Front Cover Removal; Control Box Removal - GE ASH220NCDWA Service Manual

Ductless multi-split heat pump
Hide thumbs Also See for ASH220NCDWA:
Table of Contents

Advertisement

Removing the Filter Cover & Filter
1. Slide the side latches up to unlock the cover and pull
forward about an inch then lift up.
2. The filter is very flexible and can be grabbed at any location
and removed.

Front Cover Removal

1. Remove the 4 screws that are at the corners of the air
intake opening. Gently open the horizontal louver. Lift up
the top edge of the front cover and then pull forward.

Control Box Removal

1. Remove the screw from the right side of the box cover.
2. Lift up the panel that contains the diagnostic port, wifi
module and ambient sensor. And remove the box cover.
H-4

Testing

Topic Title
3. Unplug the three connectors for the fan motor, upper
louver and bottom damper.
4. Remove the ground screw.
5. Remove the mounting screw for the box.
6. The box can now be removed.

Board Replacement

1. Follow the instructions for removing the control box.
2. Remove the cover screw from the bottom of the box, then
remove cover.
CONSOLE TECHNICAL OVERVIEW

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents