Important Safety Information

Operating Instructions

The Controls on Your Zoneline
Care of Product

Installation Instructions

Important Electrical Safety
Adjustments and Auxiliary Controls
Helpful Information
Things That Are Normal
If Something Goes Wrong
Before You Call For Service
GE Service Numbers
Warranty
GE Answer Center
800.626.2000
GE Appliances
49-7359
Zoneline
Owner's Manual
®
Zoneline Series
Heat Pump Model 3200
Heat/Cool Model 2200
®
3
4
10
19
20

Advertisement

Table of Contents
loading

Summary of Contents for GE Zoneline 3200

  • Page 1: Important Safety Information

    The Controls on Your Zoneline Care of Product Installation Instructions Important Electrical Safety Adjustments and Auxiliary Controls Helpful Information Things That Are Normal If Something Goes Wrong Before You Call For Service GE Service Numbers Warranty ® GE Answer Center 800.626.2000 GE Appliances 49-7359...
  • Page 2: Before Using

    Toll-free customer service Help us numbers are included in the back Read this manual. It contains of this manual. Or call the GE help you ® instructions to help you use and Answer Center at 800.626.2000,...
  • Page 3 IMPORTANT SAFETY INFORMATION READ ALL SAFETY INFORMATION BEFORE USING • This Zoneline must be properly • Unplug or disconnect the installed in accordance with the Zoneline at the fuse box or Installation Instructions before it circuit breaker before making is used. See pages 10-12. any repairs.
  • Page 4: Mode Control

    Operating Instructions TEMP CONTROLS MODE CONTROLS controls HIGH STOP on your HEAT COOL HIGH HIGH Zoneline HEAT COOL Temp Control Mode Control The temp control is used to maintain the HIGH COOL and LOW COOL provide cooling with room temperature. The compressor will cycle different fan speeds.
  • Page 5: Ventilation Control

    Energy Tip Keep the vent control at CLOSE . The room air will be filtered and circulated. Louver screws Louver screws Remove the room cabinet and flip the louvers to change the air direction. Vent control Ventilation Control Air Direction The ventilation control lever is located at the To adjust the air direction, remove the room lower left side of the Zoneline unit, behind the...
  • Page 6 Operating Instructions Other Zoneline features About Your Heat Pump There is a three minute minimum Heat pumps can save money by 3200 Series only removing heat from the outside compressor run time at any setting air—even when the outside to prevent short cycling. temperature is below freezing—...
  • Page 7 Auxiliary Controls The auxiliary controls are located behind the room cabinet on the front of the unit control box. The factory settings will be in the DOWN position. The owner is responsible for checking switches and ensuring they are in the desired position.
  • Page 8: Care And Cleaning

    Zoneline should be checked regularly. If they are clogged with dirt or soot they may be profes- sionally steam cleaned, a service available through your GE service outlet. You will need to remove the chassis to inspect the coils Coils...
  • Page 9 Replacement filters are available from your salesperson, GE dealer, GE Service and Parts Center or authorized Customer Care® servicers.
  • Page 10: Read Carefully

    Installation Instructions Read carefully If you have any questions, call the GE Answer Center at 800.626.2000. Replacing an Existing Unit? • Any vertical deflectors in the existing rear grille should be removed to decrease condenser air recirculation which can cause the unit to Check the “Essential...
  • Page 11 Important Electrical Safety—Read Carefully Installer: Leave these instructions with the Zoneline. Owner: Keep these instructions for future use. Important Notes • Follow the National Electrical Code (NEC) or CAUTION: local codes and ordinances. • Do not use an extension cord with this unit. •...
  • Page 12 Installation Instructions How to Connect 1 Remove the room cabinet. 3 See the special instructions below for applicable supply voltages. 2 Connect to electrical power. 4 Reinstall the room cabinet. 230/208 Volt Electrical Supply All wiring, including installation of the receptacle, must be in accordance with the NEC and local codes, ordinances and regulations.
  • Page 13 Junction relief box cover A Electrical subbase kits are available to provide a flexible enclosure for direct connection. Branch Circuit and Chassis Proper GE Slot in Amperage Rating Subbase Kit junction box Junction box RAK204E15 RAK204E20 3 Measure 6 down the cord from the strain...
  • Page 14 Installation Instructions Use the round knockout at the bottom of the 8 Reinstall the junction box by engaging the tab junction box to attach conduit coming from at the lower rear, aligning the screw hole at the the branch circuit. Remove the knockout, top and driving the one screw until secure.
  • Page 15 This chassis is designed to be installed in a with the case. GE plastic or an insulated steel wall case. This minimizes condensation from forming on the 2 Remove the corrugated stiffener and the room side of the case.
  • Page 16 Installation Instructions Install the Unit into the Wall Case Slide the unit into the wall case and secure with four screws through the unit flange holes. If an insulated wall case is needed, see Install the Wall Case and Exterior Grille section on the previous page.
  • Page 17 Low Voltage Connectors & Auxiliary Controls NOTE: The owner is responsible for checking all switches and ensuring they are set in the desired setting. Electric Heat Option—Model 3200 Series only The Electric Heat Option switch #1 increases To set the Electric Heat Option, move switch to the Zoneline air temperature by using electric the ON (up) position.
  • Page 18 Installation Instructions Remote Control/Wall Thermostat (Class 2) To operate the Remote Control/Wall Thermostat (Class 2) switch #3, you must use an Optional Interface Module kit. See the 1 2 3 4 5 6 Installation Instructions with accessory kit DOWN RAK0IM. Auxiliary Controls Central Desk Control (Load Shedding) To operate Central Desk Control (CDC),...
  • Page 19: Things That Are Normal

    Helpful Information Things That Are Normal Noise Explanation You may hear a pinging or popping noise caused by water being P I N G ! POP! picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
  • Page 20: Before You Call For Service

    If Something Goes Wrong Before You Call For Service Problem Problem Possible Causes Possible Causes What to Do What to Do Zoneline • Make sure the Zoneline plug is • Make sure the Zoneline plug is The unit is unplugged The unit is unplugged Doesn’t Start pushed completely into the outlet.
  • Page 21 If Something Goes Wrong Before You Call For Service Problem Possible Causes What to Do Burning Odor at the • This can cause a “burning” odor at the Dust is on the surface of Start of Heating beginning of the heating operation. This the heating element Operation odor should quickly fade.
  • Page 22 Notes...
  • Page 23 GE Service Numbers We’ll be there! GE Answer Center ® Open 24 hours a day, 7 days a week. 800.626.2000 800-833-4322 On-Site Repair Service We provide expert repair service, Our factory-trained technicians scheduled at a time that’s know your air conditioner inside and 800-GE-CARES convenient for you.
  • Page 24 ZONELINE Staple sales slip or cancelled check here. For service in the U.S., call Proof of original purchase date is needed 800-GE-CARES. WARRANTY to obtain service under warranty. For service in Canada, call All warranty service will be provided 1-800-361-3400.